Page 121
B. Expansion KSU with Power Supply (EKSU) The SPD 1428 Expansion KSU is a unit which comes equipped with a power supply and circuity providing four (4) additional loop start CO/PBWCentrex line ports and eight (8) digital station ports to the Basic KSU. All processing and control functions as well as voice connections and switching are controlled by circuitry on the Basic KSU and transmitted to the Expansion KSU through the ribbon cables. The Expansion key service board allows connection of one...
Page 122
STARPLUS@ SPD 1428 & 2856 Digital Key Telephone Systems _ - - _ _ _ .i¶ ~ . _ _ _ _. . ___. ,-__ . . . ..--.-............1 Figure 500-4 Expansion KSU & Main Key Service Bd (EKSU) Issue 1, November 1991 500-9
Page 123
Digital Key Telephone Systems STARPLUS@ SPD 1428 & 2856 interface circuits are protected from mis-wiring and over-current. . mes Connections: CO Lines are connected to the system via modular RJ-11 connectors accessed through the bottom of the EKSU. The Expansion KSU connects CO Line ports 9,10, 11, and 12 to the system through modu- lar connectors Jl , J2, J3, and J4 respectively. The pinouts of the modular connector are as follows: %!I ITF Stations Connections: The station ports of the SPD...
Page 124
sTARPLUS@ SPD 1428 & 2858 Digital Key Telephone Systems Table 500-2 SPD 1428 EKSU Jll Station Connections Table 500-3 SPD 1428 4x8 Expander Module Connection . PAIR PIN COLOR DESIG 1 26 WH/BL Port 013 Xmt Tip 1 BUWH Xmt Ring 2 27 WH/OR Rcve Tip 2 OR/WH Rcve Ring 3 28 WWGN Port 014 Xmt Tip 3 GNIWH Xmt Ring 4 29 WH/BN Rcve Tip 4 BN/WH Rcve Ring 5 30 WWSL Port 015 Xmt Tip 5 SUWH Xmt Ring 6 31 RD/BL Rcve Tip 6 BURD Rcve Ring 7 32 RD/OR Port 016 Xmt Tip 7 OWRD Xmt Ring 8 33 RD/GN Rcve Tip...
Page 125
Digital Key Telephone Systems sTARPLUS@ SPD 1428 & 2858 CSA 0.3 standards. CO lines are connected to the system via RJ-11 modular connectors mounted on the bottom edge of the board. The 2x4 CO/STA Expander module also provides the interface for four (4) Digital Key Telephones using two (2) 64 kilobyte channel arrangements. Stations connect to the board via the MDF through a 50 pin connector located on the main key service board inside the basic KSU or a similar connector on the expansion key...
Page 126
g. Restore power to the Expansion KSU. A No. 12 AWG stranded wire is used to connect a ground between the Expansion KSU and the 4x8 CO/Station Expander Module. A two position termi- nal strip (P3) is located along the bottom edge of the expansion key service unit and is accessible through the bottom of the BKSU. One terminal position on the P3 connector is used to connect the ground wire from the basic KSU to the Expansion KSU. The other terminal position is used to connect the ground wire from...
Page 127
500.4 SPD 2656 INSTALLATION PLANNING Prior planning of the installation will aid in a smooth cut-over and a satisfied customer. Select a suitable location for the system. Determine the number of telephones of each type, and the number of 4x8 CO/Station cards from the sales contract and discus- sions with the customer. NOTE: Only one station set is allowed per digital extension number. It is not possible to bridge digital station ports so that an extension number may ap- pear in more than one...
Page 128
sTARPLUS@ SPD 1428 & 2856 Digital Key Telephone Systems GND Figure 500-5 SPD 2856 Basic Cabinet with Power Supply Issue 1, November 1991 500-15
Page 129
Digital Key Telephone Systems STARPLUS@ SPD 1428 & 2858 supply card should be removed. If an instance arises where it must be removed, ALWAYS unplug the system AC power cord FIRST. The power supply cord plugs into an isolated, dedi- cated, (with dedicated ground) 117VAC outlet for power. This is necessary to prevent possible voltage spikes and transients that may be caused by equip- ment sharing the same AC circuit. The AC connection to the power supply requires a parallel blade with a ground...
Page 130
STARPLUS@ SPD 1428 & 2856 Digital Key Telephone Systems C. Central Processor Board (CPB) This plug-in card is the only common equipment card required to make the system operational and con- trols all system activity. The CPB contains the main micro-processor a 16-bit (68000) and a real time clock which controls all system functions including the PCM/TDM voice switching under direction of ROM and RAM software coding. The CPB is re- sponsible for all control functions, execution of all logic...