ViewSonic Cd4220 Users Guide
Here you can view all the pages of manual ViewSonic Cd4220 Users Guide. The ViewSonic manuals for Television are available online for free. You can easily download all the documents as PDF.
Page 51
5.3 Get-Function Listing The PC can interrogate the LCD Monitor for specific information. The Get-Function packet format consists of 5 bytes which is similar to the Set-Function packet structure. Note that the “Value” byte is always = 00. Get-Function description: Length: Total Byte of Message excluding “CR” TV ID Identification for each of TV Command Type Identify command type, “g” (0x67h) : Get Command Command: Function command code: One byte ASCII code Value[1~3]: Three...
Page 52
Example3: Get Tint from TV-0007 and this command is valid. The Tint value is 32. Send (Hex Format) Name Length ID Command Type CommandValue1 Value2 Value3 CR Hex 0x38 0x30 0x37 0x67 0X65 0x30 0x30 0x30 0x0D Reply (Hex Format) Name Length ID Command Type CommandValue1 Value2 Value3 CR Hex 0x38 0x30 0x37 0x72 0x65 0x30 0x33 0x32 0x0D Example4: Get Tint from TV-07 , but the Brightne ss command ID is error and it is NOT in the command table. Send (Hex Format) Name Length...
Page 53
6. Protocol 2 : without ID 6.1 Set function listing The PC can control the LCD Monitor for specific actions. The Set-Function command allows you to control the LCD monitor behavior in a remote sit through the RS232 port. The Set-Function packet format consists of 5 bytes. Note that the “Value” byte is always = 00. Set-Function description: Length: Total bytes of message = 5 ASCII (35H) excluding “CR” Command: Function command code: One byte ASCII code Value[1~3]: Three bytes ASCII...
Page 54
Brightness 5 $ 24 000 ~ 100 Sharpness 5 % 25 000 ~ 100 Color 5 & 26 000 ~ 100 Tint 5 ‘ 27 000 ~ 100 Bass 5 . 2E 000 ~ 100 Sets Bass value Treble 5 / 2F 000 ~ 100 Sets Treble value Balance 5 0 30 000 ~ 100 Sets Balance position 000 : 16:9 001 : 4:3 002 : ZOOM Picture Size 5 1 31 003 : PANORAMA 000 : English 001 : French 002 : Spanish 003 : Germany 004 : Italian 005 : Simplified Chinese OSD Language 55 2 32 006 : Russian OSD timeout 5...
Page 55
6.2 Get-Function Listing The PC can interrogate the LCD Monitor for specific information. The Get-Function packet format consists of 5 bytes which is similar to the Set-Function packet structure. Note that the “Value” byte is always = 00. Get-Function description : Length: Total bytes of message = 5 ASCII (35H), excluding “CR” Command: Get-Function command code: One byte ASCII code Value[1~3]: Always = 000 Get-Function format from PC to LCD (ASCII) Name Length Command Value1...
Page 56
Length Command CommandResponse Range Get Function Code (ASCII) Code (Hex) (Three ASCII bytes) Comments Get-Contrast a 61 000 ~ 100 Gets Contrast value Get-Brightness b 62 000 ~ 100 Gets Brightness value Get-Sharpness c 63 000 ~ 100 Gets Sharpness value Get-Color d 64 000 ~ 100 Gets Color value Get-Tint e 65 000 ~ 100 Gets Tint value Get-Volume f 66 000 ~ 100 Gets Volume value 000: OFF (unmuted)Get-Mute g 67 001: ON (muted) Gets Mute...
Page 57
ViewSonic CD4220 55 6.3 Remote Control Pass-through mode When PC sets the LCD monitor to Remote Control Pass through mode, the LCD shall send a three bytes packet (followed by “CR”) in response to RCU button activation. Note, that in this mode the RCU shall have no effect on the monitor function. For example: “+Volume” will not change the volume in the LCD but only sends “+Volume” c ode to PC over the RS232 port. Remote Control pass-through packet format from LCD monitor to PC(ASCII) Name...