Home > Uniden > Communications receiver > Uniden Receiver Bearcat BC235XLT Operating Instructions

Uniden Receiver Bearcat BC235XLT Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Uniden Receiver Bearcat BC235XLT Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 50 Uniden manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Scanning
    1. After programming
    frequencies, simply
    press
    Sto begin
    scanning.
    2. The indicator for each bank which will be scanned
    appears in the display, while the bank being
    currently monitored flashes. You can deselect banks
    from active scanning by pressing their number on
    your keypad. The indicator for each deselected bank
    turns off, and the bank’s channels are not scanned.
    Note:One Bank must always be active. You cannot
    deactivate all ten banks at the same time. If you try
    to turn all the banks off, the first bank is
    automatically selected.
    To restore a bank to active scanning, press the
    bank’s number on your keypad. The bank’s indicator
    will display again.
    3. During normal
    scanning the scanner
    skips unprogrammed
    or locked out
    channels.
    4. When a transmission
    is received, the
    Scanner stops on that
    channel. When the
    transmission ends,
    scanning resumes
    automatically.
    1 3 4 5 9  102 6 7  8CHANNELS
    Frequency not
    entered Frequency
    Locked Out
    (L/O)
    SCAN
    12345678 910
    21 
    						
    							5. PressMto stop on a
    channel during
    scanning.
    6. Press
    Sto resume
    scanning.
    Channel Lockout
    You can lockout any channel so it is not reviewed during
    normal scanning. You can restore the channel to scanning
    whenever you wish.
    Lockout in Manual Mode
    1. PressM.
    2. Select a channel.
    a. Enter the channel
    number.
    b. Then press
    Magain.
    3. Press
    Oto lockout
    the channel.
    12345678 910
    ba
    12345678 910
    12345678 910
    22 
    						
    							Lockout in Scanning Mode
    If the scanner keeps stopping on a particular channel due
    to noise or too frequent transmissions, you may want to
    keep that channel from scanning.
    1. Wait until the scanner
    stops at the channel.
    2. Then press
    O.
    3. The scanner
    immediately resumes
    scanning because the
    locked out channel is
    no longer in the
    scanning sequence.
    Lockout Tips
    To quickly lockout a series of channels, start with
    the lowest number channel.
    For example, if you are locking out channels 4, 7,
    8, 12, and 15, start with Channel 4. After selecting
    channel 4, press
    O. Then pressMone or more
    times to step up to the next channel to be locked
    out.
    Record the locked-out channels in some
    convenient place so you can restore them.
    12345678 910
    23 
    						
    							Restore a Locked Out Channel
    1. PressM.
    2. Select a locked out
    channel.
    a. Enter the channel
    number.
    b. Then press
    Magain.
    3. Press
    Oto unlock
    the channel.
    Restore All Locked-Out Channels
    You can restore all locked-out channels in a bank only
    when a bank is selected for scan. If you have deselected a
    bank and you want to restore all of its locked-out channels
    using the steps below, you must press
    Sand then press
    the number of the bank on your keypad.
    1. Press
    M.
    Note:You must be in
    Manual mode before
    restoring all
    locked-out channels.
    ba
    12345678 910
    12345678 910
    24 
    						
    							2. Press and holdOfor about two seconds.
    You will hear two
    beeps when all the
    channels have been
    restored.
    Priority Scan
    When Priority Scan is turned on, your scanner checks the
    priority channel every two seconds for activity. If a signal is
    present on the priority channel, your scanner monitors the
    channel until the transmission ends, then resumes normal
    scanning. You can designate one channel in each bank as
    a Priority Channel.
    To activate Priority Scan (in either the Manual or Scan
    Mode):
    1. Press
    P.
    Note:If you have
    locked out the priority
    channel, this
    message appears
    when you select
    Priority mode.
    2. PressPagain at
    anytime to deactivate
    Priority Scan.
    12345678 910
    12345678 910
    25 
    						
    							Changing the Priority Channel
    You cannot eliminate the Priority Channel, but you can
    change it to any of the 30 available channels in each bank.
    1. Press
    M.
    2. Select a new Priority
    Channel.
    a. Enter the channel
    number.
    b. Then press
    Magain.
    3. Press and hold
    Pfor two seconds to
    designate this
    channel as your new
    Priority Channel.
    Two beeps indicate
    that the Priority
    Channel is changed.
    ba
    12345678 910
    12345678 910
    26 
    						
    							Searching
    Setting a Search Range
    TheBC 235XLTcan search a specific frequency range to
    find frequencies if you don’t have a frequency guide
    available or if new stations have been added since your
    guide was published.
    1. Press
    Mto stop
    scanning.
    2. Using your keypad,
    enter the lowest
    frequency of your
    search range. For
    example, enter
    155.000 MHz.
    3. Press
    L.
    4. Using your keypad,
    enter the highest
    frequency of your
    search range. For
    example, enter
    157.000 MHz.
    5. Press
    L.
    6. Press
    R.
    Note:When Search mode is active, pressPto activate
    TURBOsearch to increase the search speed to
    300 steps per second in those bands which have
    5 KHz steps.
    SRCHflashes whenTURBOsearch is
    active. Press
    Pagain to cancelTURBOsearch.
    12345678 910
    12345678 910
    27 
    						
    							Search Hold Feature
    1. PressHat anytime
    to stop the search.
    2. Press
    )to move to
    the next higher
    frequency
    —OR—
    3. Press(to move
    down to the previous
    frequency.
    4. Press
    Rto resume
    searching.
    Data Skip
    A scanner will normally stop on any transmission it
    receives. This means the
    BC 235XLTwill stop on data
    signals and unmodulated transmissions. You can
    automatically skip many of these types of transmissions
    during searches.
    1. Press
    Dto activate
    the data skip feature.
    Thedindicator
    appears on the
    display.
    2. PressDagain to
    cancel the data skip
    feature.
    Thedindicator
    disappears from the
    display.
    When data skip is active, your scanner may pause
    momentarily on an unwanted signal but will resume
    searching in 2 or 3 seconds. Data Skip does not function
    when the
    AIRBand is selected.
    12345678 910
    12345678 910
    12345678 910
    12345678 910
    12345678 910
    28 
    						
    							Channel Skip
    If a particular channel continues to interrupt search
    scanning, it is possible to set your scanner to skip the
    frequency.
    To skip a frequency,
    press
    O.
    Note:You can
    program up to 20 skip
    frequencies. The 21st
    skip frequency
    entered causes the
    first skipped
    frequency to unlock.
    Storing Search Frequencies
    You can quickly store any frequency you find during
    Search.
    Caution:You must select the channel in which you will
    store the frequency before entering the search
    mode. Otherwise, you may erase a stored
    frequency that you want to keep.
    1. PressM.
    2. Using your keypad,
    enter the lowest
    frequency of your
    search range. For
    example, enter
    155.000 MHz.
    3. Press
    L.
    4. Using your keypad,
    enter the highest
    frequency of your
    search range. For
    example, enter
    157.000 MHz.
    12345678 910
    12345678 910
    29 
    						
    							5. PressL.
    6. Press
    R.
    7. Press
    Hwhen the
    scanner stops at the
    frequency you want.
    8. Press
    Eto store the
    frequency in the
    channel you selected.
    Note:After this step
    you are in manual
    mode.
    9. To store another
    frequency, select
    another channel for
    the new frequency.
    10. Repeat steps 6
    through 8 for all the
    Search frequencies
    you want to store.
    12345678 910
    12345678 910
    30 
    						
    All Uniden manuals Comments (0)

    Related Manuals for Uniden Receiver Bearcat BC235XLT Operating Instructions