Home > Uniden > Communications receiver > Uniden Receiver Bearcat BC235XLT Operating Instructions

Uniden Receiver Bearcat BC235XLT Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Uniden Receiver Bearcat BC235XLT Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 50 Uniden manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							3. Replace cover and
    press down until it
    clicks into place.
    Charging the Battery Pack
    Use the AC Adapter/Charger to power theBC 235XLT
    from an AC outlet.
    You can use your scanner while the battery charges. To
    fully charge the battery, leave the AC Adapter/Charger
    connected for 14 – 16 hours.
    Note:Disconnect the AC Adapter/Charger from the unit
    when charging is complete.
    Use only the supplied AC Adapter
    (AD70U)or one of the optional power
    cords
    (WZ1015 or WZ1017).
    11 
    						
    							CRX120 Battery Charger
    The CRX120 charger allows you to charge the extra
    battery included with your scanner. You can also charge
    the battery inside your scanner at the same time. This way
    you can always have a charged battery ready to go.
    Charging the Spare Battery
    To fully charge the extra battery in the CRX120, you
    should leave the battery in the charger for 14 – 16 hours.
    1. Plug the cable from
    the BP180 into the
    connector in the
    CRX120. Make sure
    the red wire matches
    REDand the black
    wire matches
    BLKon
    the charger.
    2. Place the battery in
    the charger, and plug
    the AC Adapter into a
    wall outlet.
    Then connect the
    adapter to the
    charger.
    The red LED on the
    charger will light,
    indicating that the
    battery is charging.
    CHARGE
    BLKRED
    DC IN 12 V
    12 
    						
    							Connecting the Charger to Your Scanner
    You can charge both batteries at the same time. To fully
    charge both batteries, you should leave the AC
    Adapter/Charger connected for 14 – 16 hours.
    1. Follow steps 1 and 2
    under
    Charging the
    Spare Battery
    on
    page 12, then
    connect the charging
    lead on the CRX120
    to the charging jack
    on your scanner.
    2. When charging is
    complete, disconnect
    the CRX120 from
    your scanner, then
    unplug the AC
    Adapter/Charger from
    the CRX120.
    Adapter Safety Feature
    The AC Adapter included with this scanner may be
    equipped with a polarized line plug — a plug with one
    blade wider than the other. This plug will fit into a power
    outlet only one way. If you are unable to insert the
    adapter’s plug into an outlet, try reversing the plug.
    DC IN 12 V
    13 
    						
    							Flexible Antenna
    Belt Clip
    Attach the flexible antenna to the
    BNCconnector.
    Do not tighten the screws too tight.
    You can damage the case or clip.
    14 
    						
    							Basic Operation
    Note:You can fold out the Front Cover to see the
    Controls and Indicators while reading this Guide.
    Setting the Squelch
    To set the squelch, you must be in the Manual mode, and
    you should not be receiving a signal on your scanner.
    1. Press
    Muntil you do
    not hear a signal.
    2. Adjust
    VOLUMEto a
    comfortable listening
    level.
    3. Think of the Squelch Control as a gate. Turn
    SQUELCHfully counter-clockwise. This raises the
    “Squelch Gate” so high that only very strong signals
    can get through.
    STRONG SIGNALS
    MEDIUM SIGNALS
    WEAK SIGNALS
    NOISE
    15 
    						
    							4. TurnSQUELCHfully clockwise until you hear a hiss.
    This lowers the “Squelch Gate” so that everything
    gets through—noise, weak signals, and strong
    signals.
    5. Turn
    SQUELCHback counter-clockwise just until the
    hiss stops. Now the “Squelch Gate” allows only
    clearer signals through.
    Keylock
    Key Lock prevents accidental key entries during
    conventional scanning or while in trunk tracking mode.
    1. To lock the keypad,
    press and hold
    LOCK
    until thesymbol
    appears in the lower
    right of the display.
    2. To unlock the keypad,
    press and hold
    LOCK
    until thesymbol
    in the lower right of
    the display turns off.
    STRONG SIGNALS
    MEDIUM SIGNALS
    WEAK SIGNALS
    NOISE
    STRONG SIGNALS
    MEDIUM SIGNALS
    WEAK SIGNALS
    NOISE
    12345678 910
    12345678 910
    16 
    						
    							Programming
    Before theBC 235XLTcan begin conventional scanning,
    you must program a frequency into at least one channel.
    Repeat this procedure for each channel you want to
    program.
    1. Select frequencies
    from your starter
    guide.
    2. Press
    M.
    3. Select a channel.
    a. Enter the channel
    number.
    b. Then press
    M.ba
    12345678 910
    17 
    						
    							4. Enter the frequency.
    a. Enter the frequency
    number.
    b. Then press
    E.
    Note:To clear a mistake while entering the frequency,
    press
    .twice, and start over.
    If you enter a
    frequency which is
    outside the scanner’s
    frequency bands, a
    distinctive beep
    sounds.
    Press
    .and go
    back to Step 4.
    (See the Table on page 3 or the Band List on the
    back of the scanner).
    a
    b
    12345678 910
    12345678 910
    18 
    						
    							Duplicate Frequency Alert
    If you enter a
    frequency which is
    stored in another
    channel, you hear a
    beep and the other
    channel displays.
    Press
    .to start
    again
    —OR—
    PressEagain to
    store the frequency in
    both channels.
    Programming Tips
    Do not program a weather frequency into one of
    the channels, since weather channels transmit
    continuously.
    Use
    Cto select the weather information band.
    Group similar frequencies into adjacent channels.
    For example, program police frequencies in
    channels 1 through 10 and fire/emergency into
    channels 11 through 20, and so on.
    Put the frequency that you listen to the most or the
    most important frequency into a Priority channel.
    To quickly program a series of channels, start with
    the lowest number channel.
    For example, when you are programming five new
    frequencies into Channels 4 through 8, start with
    Channel 4. After you finish programming a
    channel, press
    Mor)to go to the next higher
    channel.
    Record channels and frequencies in some
    convenient place in case the scanner memory is
    lost.
    12345678 910
    19 
    						
    							Deleting a Stored Frequency
    To delete a stored
    frequency:
    a. Press
    0.
    b. Then press
    E.
    Channels with no
    frequencies are
    automatically locked
    out.
    12345678 910
    20 
    						
    All Uniden manuals Comments (0)