Page 141

OPERATING PROCEDURES 
SECTION 100-020-400 
JANUARY 1984 
05.00.3 
The active pattern is shown by the 
state of the NT LED as follows: 
Three-pattern Two-pattern 
DAY OFF OFF 
DAY 2 FLASH 
N/A 
NITE ON ON 
-14-  

Page 142

~~SH~BA SYSTEM PRACTICES 
ELECTRONIC KEY TELEPHONE SYSTEM FAULT FINDING 
SECTION 100-020-500 
_ JANUARY 1984 
l . 
XII&xx 
FAULT FINDING 
PROCEDURES  

Page 143

FAULT FINDING 
SECTION 100-020-500 
JANUARY 1984 
FAULT FINDING PROCEDURES 
TABLE OF CONTENTS 
PARAGRAPH SUBJECT PAGE 
TABLE of CONTENTS. ........................................... 
i 
01 GENERAL 
..................................................... 1 
02 FAULT CLASSIFICATION ........................................ 
1 
03 FAULT CLEARING PROCEDURES ................................. 
1 
04 DEFECTIVE APPARATUS RETURNS ............................... 
1 
05 FAULT IDENTIFICATION AND ELIMINATION PROCEDURES...

Page 144

01 GENERAL 
01.01 This section describes the maintenance 
procedures used for the diagnosis of faults in the 
STRATA XII & XX electronic key telephone 
systems. Faults are classified and then cleared by 
replacing apparatus and performing operational 
tests in the sequences prescribed by the fault 
clearing flow charts in Paragraph 05. 
02 FAULT CLASSIFICATION 
02.01 A fault classification flow chart is pro- 
vided to ensure that fault clearing is pursued in 
a logical sequence (Chart No. 1). 
02.02 In...

Page 145

FAULT FINDING 
SEaION 100-020-500 
JANUARY 1984 
START AND END OF 
A FLOW CHART SEQUENCE 
IMPORTANT NOTES 
AFFECTING THE FAULT 
CLEARING PROCEDURE 
QUESTION TO BE ANSWERED 
YES OR NO 
PROGRESSION TO OR FROM 
ANOTHER FLOW CHART LOCATION. 
LETTER WILL DENOTE EXACT ENTRANCE 
OR EXIT POINT 
STATEMENT OF A 
REQUIRED ACTION 
I 
0 
0 
TO/FROM SPECIFIC FLOW CHART (FC) 
FIGURE 1 -FLOW CHART SYMBOLS 
a) 
Paper container for the MCAU/AMMU, MSMU 
AND CRDU PCBs. 
b) 
Anti-static container for all other PCBs. 
c)...

Page 146

‘. FAULT FINDING 
SECTION 100-020-500 
JANUARY 1984 
NOTE: 
: .. 1. 
2. 
The CRDU PCB is not considered sep- 
arately from its host PCBs in any flow 
chart except the Automatic Dialing Fault 
flow chart. 
If a CRDU is equipped, remove the CRDU 
when substituting a host PCB (MCBU 
or MDSU) and reinsert the same host 
PCB into the MKSU. If the fault is cleared, 
replace the defective CRDU. 
TABLE A 
STATION CABLE CONTINUITY CHECK USING 
VOLTMETER 
NOTE: 
Perform the following at the locations in- 
dica...

Page 147

FAULT FINDING 
SECTION 100-020-500 
JANUARY 1984 
Input 
+24V 
From 
EPSA 
104 
TABLE C 
STRATA XII & XX POWER DISTRIBUTION ’ 
r 
Bower Switch I ,nter. Breaker 
SW1 
MPRU 
Fl 
(24Vnl) 
(24L2, 
list. Breaker 
Voltage 
(Et&2) 24V#l 
IEKFT5#33) 24V#l 
(EKFT694) 24V#l 
24V#2 
(MZ”, 
+12 
VI 
1 
+5 
PCB Served 
F&l-” 
#l (SXII) 
#l, 2 (SXX) 
MSTU 
#2 (SXII) 
#3,4 (SXX) 
MSTU 
#3 (SXII) 
#5,6 LSXX) 
MSTU 
#4 (SXll) 
#7 (SXX) 
MCOU 
MDSU 
MINU 
MSMU 
MCOU MXPU 
MOPU MSTU 
MCAU MSMU 
MCBU MDSU 
MINU 
MINU 
MXPU...

Page 148

FAULT FINDING 
SECTION 100-020-500 
JANUARY 1984 
TBl 
SW1 
+24V 
__c.. 
ON/OFF EKT #3 
(F6) 
_i-,2.OA 
EKT #4 
y&z 
KSU  SPSA 
104 
- 
1 1AB. 
2AB 
. . 
3 
3Ab. 
4AB 
7 
7AB. 8AB 
1 
38AB, 39AB 
2 
36AB. 37AB 
3 
34AB: 35AB 
32AB. 33A8 
9AB. 1OAB 
16AB. 17AE 
6 _L 
15AE 
I-- 
-/- + 23AB. 24AE 
12AB 
13AB 
14AB 
5 
1 26AB 
27AB 
28AB 
I 
+24V #I 
1 24V #l 
GRD 
+24V $2 
24V #2 
GRD 
+12v 
Vl 
12V GRD 
+5v 
5V GRN 
FIGURE 2 -SIMPLIFIED MPRU SCHEMATIC 
-5-  

Page 149

FAULT FINDING 
SECTION 100-020-500 
JANUARY 1984 
TABLE D 
STRATA XII & XX CROSSPOINT MATRIX LOCATION 
STRATA Xii & XX 
STRATA XX 
PRIMARY MATRIX* 
EXPANSION 
I 
lOwI MSTU #l 
MXPU #l MXPU #2 
18~25 MSTU #2 
26~33 ! MSTU *3 MXPU #2 (SXII) 
MSTU #4 MXPU #3 
(SXX) MXPU #4 
34pv41 
42%49 MSTU #5 
MXPU ~$5 
MXPU #6 
50-57 MSTU #6 
58~65 MSTU +7 MXPU #7 
MXPU #8 
“IMPORTANT.. 
In its power-up sequence, the STRATA software verifies that the primary matrix (MXPU) 
exists for each MSTU. if an MSTU is installed...

Page 150

To 
To 
To 
CHART NO. 1 
FAULT CLASSIFICATION 
Please read the 
maintenance 
information 
before proceeding. 
i 
START 
FAULT FINDING 
SECTION 100-020-500 
- JANUARY 1984 
l 
I Start here to 
clear faults I in the 
STRATA 
system. 
Check fuses, 
circuit breakers 
and power 
indxators. 
To 
indicators, fuses NO 
NO 
access intercom 
or at least one NOTE: Verify 
MXPU locations 
per Table D.  