Page 11
STRATA Se/We GENERAL DESCRIPTION NOVEMBER 1987 OPT11 l lA2 Key System Interface (HCNB) 0 Amplified Conference l Auxiliary Device Interface (HIOB) l Background Music with Station Control l Door Phone/Monitor Station l Alarm Button l Door Lock Button l Electronic Telephones * Facepiates (blue, black or wine) 0 Single-line l 1 O-button Handsfree Answerback Speakerphone l lo-button Busy Lamp Field l 20-button Handsfree Answerback Speakerphone l 20-button Liquid Crystal Display TABLE C...
Page 12
STRATA Se/We GENERAL DESCRIPTION NOVEMBER 1987 Key Ser I Batten/ I External Speaker (HESB) External Music Source Standard Phone ice Unit Standard Phone Door Phone 20-button LCD Electronic Telephone -CO/PBX Lines ___t f IGURE 15-SYSTEM DIAGRAM 06 SYSTEM CONFIGURATION / Key Service Unit Complete with all available options, both key service units utilize up to eight printed cir- cuit boards internally (as shown in Figures 17 The STRATA Se key service unit arrange- ment illustrated...
Page 13
STRATA Se/We GENERAL DESCRIPTION NOVEMBER 1987 STRATA Se 1 O-button CI ^--_^- :^ SSTU tt14 - 17 20.bunon LCD Electronic Telephone i Station MOH Door Phone/ Monitor Station STRATA SSTU #2 t122 - 25 I I -6 I I To CO/PBX (6 Lines) I ‘- 1 O-buttm Electronic Telephone 20-button LCD Electronic Telephone FIGURE 16-FUNCTIONAL BLOCK DIAGRAM -ll-
Page 14
STRATA Se/We GENERAL DESCRIPTION NOVEMBER 1987 STMU SDTU SEPU / . FIGURE 17 STRATA Se KEY SERVICE UNIT (with PC&) and from the station: b) CO Interface: An interface between the key service unit and the public telephone network or PBX for up to two lines (STRATA Se) or up to three lines (STRATA Vie). Ring detection, hold and dial outpuls- ing for these lines are performed by this board. Depending upon local CO require- ments, each incoming line can be sepa- rately connected and...
Page 15
/. SDTU: Provides Remote Administration/Main- tenance access via its built-in 300/l 200 baud modem. One SDTU per system is re- quired for Remote Administration/Mainten- ance. STMU: Required for connection to an HSMB to provide SMDR for a STRATA Se key service unit. HPSU 6120/7120: Each system’s required voltages are provided by one of these factory- installed power supplies. The HPSU connects to a standard 3-wire, 117 VAC, 60-Hz, grounded wall outlet, with a permissible AC input voltage...
Page 16
STRATA Se/We GENERAL DESCRIPTION NOVEMBER 1987 HIOB: Provides one circuit to interface with ex- ternal devices such as a voice mail port, an- swering machine, standard telephone, mo- dem, etc. Up to eight HlOBs (four on a STRATA Se) may be installed on a system. Each HI06 is connected to a proprietary sta- tion port, reducing station capacity accord- ingly. Station Equipment The principal components of the electronic telephone are: handset, dial pad, speaker, micro- phone, two volume...
Page 17
each line) single-pair modular cords or a single 3-pair modular cord (STRATA Se); or two 3-pair or six single-pair modular cords (STRATA Vie). b) The station connection points are extended from the key service unit to the main distri- bution frame using 3-pair modular line cords. The individual telephones are connected to the main distribution frame using 3-pair sta- tion cables. c) A screw-terminal barrier strip is mounted on the left-hand side of the key service unit to provide attachment...
Page 18
STRATA Se/‘& GENERAL DESCRIPTION NOVEMBER 1987 DTMF and Dial Pulse CO Line Compatible: The system will interface with either DTMF or rotary-dial pulse CO lines on a line-by-line basis as determined by system programming. External Page Interface: A 600-ohm connec- tion point is provided for a customer-provided external amplifier/speaker. An SEPU PCB (see External Amplified Speaker and External Page Amplifier) is mounted in the key service unit when a customer-provided external speaker only is...
Page 19
INSTALLATION INSTRUCTIONS SECTION 500-036-200 JANUARY 1988 Stratae HKSU ---- - Normal Talk Path - - OCA Talk Path EKT B I slatm Card B --_- $+---++--. i/o1ce Da,r ------------____’ 8 OCA Pall I I I I I Stamn Card A EKT A I Data Par I t CONTROL 1 V31ce Patr HANDSET ----.----_____ (Talk Path 1) I---- I ----1 IT1 4 i I ‘Y RiCE’VEA ’ I FIGURE 25-OFF-HOOK CALL ANNOUNCE FUNCTIONAL BLOCK DIAGRAM 0 If in automatic mode*: Station A receives a single tone burst (an OCA speech path exists...
Page 20
INSTALLATION INSTRUCTIONS SECTION 500-036-200 JANUARY 1988 5) Repeat step 4 at the lA2 telephone, and all appropriate telephones in both systems. NO TE. Exclusive hold is a function of each system (i.e., if a station places a line on exclusive hold, but the IA2 system does not provide this feature, the line may be picked up by any 1 A2 telephone (and vice versa). 09.20 HI06 09.21 General: Prqvides a circuit interface with the system for external devices such as a voice mail machine,...