Strata DK424i Functional Block Diagrams Strata DK General Description 6/0035 Functional Block Diagrams The Functional Block Diagrams show the PCBs and interface connectors used for connecting the stations and peripherals (see Figures 12~14). Figure 12 KSU Processor and Optional Interface PCBs Data and Speech Highway 25-pair or Terminal Strip(N/A RSSU) 5210 IMDU B_C_U Micro- Processor (68000 or 68020) Flash or RAMProcessor PCB (Optional) PCM Switch System Tones Switch DTMF Receiver (4~24 ckts.) Conf...
Page 52
Strata DK424i Functional Block Diagrams 36Strata DK General Description 6/00 Figure 13 CO Line Side Functional Block Diagram RDTU2•2T1 / DS1(24 Channels / Lines) •Loop Start, Ground Start, Tie, DID •Digital Voice Lines Channel Service Unit (CSU) 25-pair Amphenol TOSHIBA NDTU Cable DB15 PLL Synchronization Circuits 2 RCOU4 Loop Start Co Lines (Analog) RGLU24 Loop or Ground Start CO Lines (Analog) RCOS (Optional PCB on RCOU Only):4 Loop Start CO Lines (Analog) RCIU2 RCIS4 Caller ID Circuits 4 Caller ID...
Page 53
Strata DK424i Functional Block Diagrams Strata DK General Description 6/0037 Figure 14 Station Side Functional Block Diagram S4R4 S4 U4 U4 RATU4 Attendant Console Circuits RBSU3 2B+1D/Circuit (2-NT Circuits) RBUU3 2B+1D/Circuit (2-LT Circuits) 1 1 1 1 1 1 1 1 EOCU(Option PCB to Receive Speaker OCA) RDSU4 Digital Telephone Circuits 2 Standa rd Telephone Circuits PDKU28 Digital Telephone Circuits RWIU32 Digital Wireless Telephone Circuits RSTS(Option PCB) 2 Standard Telephone CircuitsR48S(Option PCB,...
Page 54
Strata DK424i Maintenance and Programming 38Strata DK General Description 6/00 Maintenance and Programming Hardware maintenance and repair procedures describe how to quickly locate, remove, and replace defective parts and PCBs. System programming can be performed without taking the system out- of-service. On-site programming can be executed with any 20-button proprietary LCD telephone or with a DKi Admin PC connected to an optional maintenance port. Off-site programming with DKi Admin is available...
Page 55
Strata DK General Description 6/0039 Universal Slot PCBs4 This chapter describes each of the PCBs that install into the universal slots of the Strata DK40i Expansion KSU, the DK424i Base/Expansion Cabinets. The following paragraphs categorize the cards according to their function. Descriptions here apply to both DK40i, DK424i unless noted otherwise. The DK14 does not support any universal slot PCBs. Feature subassemblies that plug onto a universal slot PCB, such as the Standard Telephone...
Page 56
Universal Slot PCBs Station PCBs 40Strata DK General Description 6/00 Standard Telephone Interface Subassembly (RSTS) The RSTS attaches to the RDSU and adds two standard telephone circuits to the PCB. With the RSTS installed, the RDSU provides four standard telephone circuits and four digital telephone circuits. (RSTS does not support standard telephone message waiting.) Strata AirLink Wireless Interface Unit (RWIU) The RWIU interfaces the DK40i, DK424i with the Strata AirLink Telephone wireless...
Page 57
Universal Slot PCBs Console PCBs Strata DK General Description 6/0041 This PCB also supports the Message Waiting feature on standard telephones that are equipped with a 90VDC neon message waiting lamp. The RSTU2 also provides an 80V RMS sine wave ring generator and has interface connectors for an optional R48S subassembly that increases the maximum possible station loop length from 600 to 1200 ohms. DK40i – a K5RCU or K5RCU2 must be installed in the Base KSU to interpret DTMF tones transmitted by...
Page 58
Universal Slot PCBs CO Line PCBs 42Strata DK General Description 6/00 RCIS can provide a maximum of eight Caller ID circuits per cabinet slot. Built-in gas tubes help protect each RCIU2/RCIS circuit from lightning surges. Loop Start CO Line Interface Unit (RCOU) The RCOU in its basic configuration has four analog loop start CO line circuits, connecting to the public telephone network. Each RCOU line can be programmed for DTMF or Dial Pulse signaling and has a switch to control potential excess...
Page 59
Universal Slot PCBs CO Line PCBs Strata DK General Description 6/0043 Voice Over IP Gateway (BVPU) The BVPU combines the functions of a four-circuit REMU E&M Tie line card and a Voice Over Internet Protocol (IP) gateway on a single PCB. The BVPU is an H.323 Version 2 compliant gateway and can interoperate with other H.323 devices as well as other BVPUs. The BVPU allows multiple Strata DKs to establish virtual Tie line connections across an IP network. The BVPU connects to the LAN through an RJ45,...
Page 60
Universal Slot PCBs CO Line PCBs 44Strata DK General Description 6/00 A maximum of two simultaneous voice and/or data calls are allowed between all devices connected to the same BRI circuit. The contention rule for the two BRI B channels is first come, first serve. Network connections using BRI S/T type interface also require a dealer-supplied, UL-listed, external Network Terminal (NT-1) device. In Canada, the NT-1 must be CSA certified. Basic Rate Interface Subassembly (RBSS) The RBSS attaches to...