Page 41
Strata DK424i ISDN BRI Circuit Capacity Guidelines Strata DK General Description 6/0025 ISDN BRI Circuit Capacity Guidelines The tables in this section show the maximum capacities for ISDN BRI circuits using RBUU/ RBUS and/or RBSU/RBSS PCBs. Guidelines 1~7 below apply to Tables 16~19. 1. Each BRI circuit can be configured to support either one BRI (TE or TA) ISDN station; or two ISDN line channels. 2. A maximum of eight BRI circuits may be used as BRI line circuits to connect to the ISDN Central...
Page 42
Strata DK424i ISDN BRI Circuit Capacity Guidelines 26Strata DK General Description 6/00 Configurations using analog line circuits are shown in Ta b l e 1 4. Configurations using T1 and/or ISDN PRI lines are shown in Table 15. All capacity configurations Tables 14~23 assume one universal slot is used for an External Page/Maintenance interface PCB. Table 18 B3CAU/B3CBU Maximum ISDN BRI ConfigurationTable 19 B5CAU/B5CBU Maximum ISDN BRI Configuration B3CAU/B3CBU 3 Cabinets 28 Universal Slots 192...
Page 43
Strata DK424i ISDN BRI CIrcuit Capacity Guidelines Strata DK General Description 6/0027 ISDN BRI CIrcuit Capacity Guidelines The tables in this section show the maximum capacities for ISDN BRI circuits using RBUU/ RBUS and/or RBSU/RBSS PCBs. Guidelines 1~7 below apply to Tables 20~23. 1. Each BRI circuit can be configured to support either one BRI (TE or TA) ISDN station; or two ISDN line channels. 2. A maximum of eight BRI circuits may be used as BRI line circuits to connect to the ISDN Central...
Page 44
Strata DK424i ISDN BRI CIrcuit Capacity Guidelines 28Strata DK General Description 6/00 Table 21 B2CAU/B2CBU Maximum ISDN BRI Configuration B2CAU/B2CBU 2-Cabinets 14-Universal Slots 104-Stations Max. 120-CO Lines Max. 128-Stations + Lines Max. BRI Circuits (2B + 1D channel each)Other Stations & Lines Combined (see Guidelines 4 & 5 on Page 27) 30 8 26 24 22 40 18 56 14 72 10 88 6 104 2 120 0 128 Table 22 B3CAU/B3CBU Maximum ISDN BRI Configuration B3CAU/B3CBU 3-Cabinets 28-Universal Slots...
Page 45
Strata DK424i ISDN BRI CIrcuit Capacity Guidelines Strata DK General Description 6/0029 Table 23 B5CAU/B5CBU Maximum ISDN BRI Configuration B5CAU/B5CBU 5-Cabinets 48-Universal Slots 336-Stations max. 200-CO Lines max. 432-Stations + Lines Max. BRI Circuits (2B + 1D channel each)Other Stations & Lines Combined (see Guidelines 4 & 5 on Page 27) 72 144 68 160 64 176 60 192 56 208 52 224 48 240 44 256 40 272 36 288 32 304 28 320 24 336 20 352 16 368 12 384 8 400 4 416 0 432
Page 46
Strata DK424i Remote Expansion Cabinet Unit 30Strata DK General Description 6/00 Remote Expansion Cabinet Unit The RRCU PCB enables a DK424i Expansion Cabinet to be located up to three kilometers from its Base Cabinet. One RRCU connects to up to two ribbon-type Data Cables and applies the inter- cabinet signal to a fiber-optic pair. One fiber pair can support one or two expansion cabinets in one remote location using one RRCU in the Base Cabinet and another in the Remote Expansion Cabinet. A DK424i...
Page 47
Strata DK424i Primary/Reserve Power Cabinet Hardware Strata DK General Description 6/0031 Table 26 Typical Reserve Power Duration Estimates (in hours) Primary/Reserve Power Cabinet Hardware The lightweight and compact design enables easy wall or floor mounting. The BFIF hardware kit is needed for floor mounting (see Ta b l e 2 7). If floor mounting three or more cabinets, AC and reserve power must be connected to the BCCB conduit connection box option by a licensed electrician. If more than two...
Page 48
Strata DK424i Primary/Reserve Power Cabinet Hardware 32Strata DK General Description 6/00 Table 27 Power Cabinet Hardware OptionDescription BPSU672DK424i cabinet power supply. This power supply can operate with 120VAC, 208VAC, or 240VAC connected as the system’s primary AC power source. It automatically detects and adjusts to the type of primary AC power that is connected. The power supply is included with each cabinet ordered but must be installed in the field. Standard 9 ft. AC power cords...
Page 49
Strata DK424i Primary/Reserve Power Cabinet Hardware Strata DK General Description 6/0033 BBTC1A-2.0MA two-meter battery cable used to connect reserve power batteries to the BBDB battery distribution box. One reserve power cable is required in a three or four cabinet system and two cables are required for five cabinet systems (wall or floor mount). The cable connects DK424i BBDB box directly to the battery terminals. BCCB120 or BCCB240DK424i conduit connection box is installed in the bottom...
Page 50
Strata DK424i DK424 and DK424i Hardware Compatibility 34Strata DK General Description 6/00 DK424 and DK424i Hardware Compatibility The following tables shows the PCB compatibility for the DK424 and D424i systems. CategoryUnit NameDK424DK424i Processor CardRCTU cards for DK424 X NC B_C_U cards for DK424i NC X DTMF Receiver UnitRRCS-4/8/12 X NC BRCS-4/8/12 NC X Optional Interface Unit RSIUXX PIOUXX RSSU X X PIOUS X X Te r m i n a l EKT2000 X X EKT6000 X X EKT6500 X X HDSS X X Existing Proprietary...