Home > Toshiba > Telephone > Toshiba Strata Dk14, Dk40i, Dk424i General Description Manual

Toshiba Strata Dk14, Dk40i, Dk424i General Description Manual

Here you can view all the pages of manual Toshiba Strata Dk14, Dk40i, Dk424i General Description Manual. The Toshiba manuals for Telephone are available online for free. You can easily download all the documents as PDF.

Page 41

Strata DK424i
ISDN BRI Circuit Capacity Guidelines
Strata DK General Description    6/0025
ISDN BRI Circuit Capacity Guidelines
The tables in this section show the maximum capacities for ISDN BRI circuits using RBUU/
RBUS and/or RBSU/RBSS PCBs. Guidelines 1~7 below apply to Tables 16~19.
1. Each BRI circuit can be configured to support either one BRI (TE or TA) ISDN station; or two 
ISDN line channels.
2. A maximum of eight BRI circuits may be used as BRI line circuits to connect to the ISDN 
Central...

Page 42

Strata DK424i
ISDN BRI Circuit Capacity Guidelines
26Strata DK General Description    6/00
 
Configurations using analog line circuits are shown in Ta b l e  1 4. Configurations using T1 and/or 
ISDN PRI lines are shown in Table 15. All capacity configurations Tables 14~23 assume one 
universal slot is used for an External Page/Maintenance interface PCB.
Table 18 B3CAU/B3CBU Maximum ISDN
BRI ConfigurationTable 19 B5CAU/B5CBU Maximum ISDN BRI 
Configuration
 
B3CAU/B3CBU
3 Cabinets
28 Universal Slots
192...

Page 43

Strata DK424i
ISDN BRI CIrcuit Capacity Guidelines
Strata DK General Description    6/0027
ISDN BRI CIrcuit Capacity Guidelines
The tables in this section show the maximum capacities for ISDN BRI circuits using RBUU/
RBUS and/or RBSU/RBSS PCBs. Guidelines 1~7 below apply to Tables 20~23.
1. Each BRI circuit can be configured to support either one BRI (TE or TA) ISDN station; or two 
ISDN line channels.
2. A maximum of eight BRI circuits may be used as BRI line circuits to connect to the ISDN 
Central...

Page 44

Strata DK424i
ISDN BRI CIrcuit Capacity Guidelines
28Strata DK General Description    6/00
Table 21 B2CAU/B2CBU Maximum ISDN BRI Configuration
B2CAU/B2CBU
2-Cabinets
14-Universal Slots
104-Stations Max.
120-CO Lines Max.
128-Stations + Lines Max.
BRI Circuits 
(2B + 1D channel each)Other Stations & Lines 
Combined (see Guidelines 
4 & 5 on Page 27)
30 8
26 24
22 40
18 56
14 72
10 88
6 104
2 120
0 128
Table 22 B3CAU/B3CBU Maximum ISDN BRI Configuration
B3CAU/B3CBU
3-Cabinets
28-Universal Slots...

Page 45

Strata DK424i
ISDN BRI CIrcuit Capacity Guidelines
Strata DK General Description    6/0029
Table 23 B5CAU/B5CBU Maximum ISDN BRI Configuration
B5CAU/B5CBU
5-Cabinets 
48-Universal Slots
336-Stations max.
200-CO Lines max.
432-Stations + Lines Max.
BRI Circuits 
(2B + 1D channel each)Other Stations & Lines 
Combined (see Guidelines 
4 & 5 on Page 27)
72 144
68 160
64 176
60 192
56 208
52 224
48 240
44 256
40 272
36 288
32 304
28 320
24 336
20 352
16 368
12 384
8 400
4 416
0 432 

Page 46

Strata DK424i
Remote Expansion Cabinet Unit
30Strata DK General Description    6/00
Remote Expansion Cabinet Unit
The RRCU PCB enables a DK424i Expansion Cabinet to be located up to three kilometers from its 
Base Cabinet. One RRCU connects to up to two ribbon-type Data Cables and applies the inter-
cabinet signal to a fiber-optic pair. One fiber pair can support one or two expansion cabinets in one 
remote location using one RRCU in the Base Cabinet and another in the Remote Expansion 
Cabinet.
A DK424i...

Page 47

Strata DK424i
Primary/Reserve Power Cabinet Hardware
Strata DK General Description    6/0031
Table 26 Typical Reserve Power Duration Estimates (in hours)
Primary/Reserve Power Cabinet Hardware
The lightweight and compact design enables easy wall or floor mounting. The BFIF hardware kit 
is needed for floor mounting (see Ta b l e  2 7). If floor mounting three or more cabinets, AC and 
reserve power must be connected to the BCCB conduit connection box option by a licensed 
electrician. If more than two...

Page 48

Strata DK424i
Primary/Reserve Power Cabinet Hardware
32Strata DK General Description    6/00
Table 27 Power Cabinet Hardware 
OptionDescription
BPSU672DK424i cabinet power supply. This power supply can operate with 120VAC, 208VAC, or 240VAC 
connected as the system’s primary AC power source.  It automatically detects and adjusts to the 
type of primary AC power that is connected. The power supply is included with each cabinet 
ordered but must be installed in the field. 
Standard 9 ft. AC
 power cords...

Page 49

Strata DK424i
Primary/Reserve Power Cabinet Hardware
Strata DK General Description    6/0033
BBTC1A-2.0MA two-meter battery cable used to connect reserve power batteries to the BBDB battery 
distribution box. One reserve power cable is required in a three or four cabinet system and two 
cables are required for five cabinet systems (wall or floor mount). The cable connects DK424i 
BBDB box directly to the battery terminals.
BCCB120 or 
BCCB240DK424i conduit connection box is installed in the bottom...

Page 50

Strata DK424i
DK424 and DK424i Hardware Compatibility
34Strata DK General Description    6/00
DK424 and DK424i Hardware Compatibility
The following tables shows the PCB compatibility for the DK424 and D424i systems.
CategoryUnit NameDK424DK424i
Processor CardRCTU cards for DK424 X NC
B_C_U cards for DK424i NC X
DTMF Receiver UnitRRCS-4/8/12 X NC
BRCS-4/8/12 NC X
Optional Interface Unit
RSIUXX
PIOUXX
RSSU X X
PIOUS X X
Te r m i n a l
EKT2000 X X
EKT6000 X X
EKT6500 X X
HDSS X X
Existing Proprietary...
Start reading Toshiba Strata Dk14, Dk40i, Dk424i General Description Manual

Related Manuals for Toshiba Strata Dk14, Dk40i, Dk424i General Description Manual

All Toshiba manuals