Page 51

INSTALLATlONlNSTRUCTlONS 
SECTION 200-255-204 
FEBRUARY1992 
FIGURE 4-38-INSTALLING DDIU-MAT 
Pin No. Designation 
1 FG Protective Ground/Frame 
2 SD Transmitted Data (to DDIU) 
3 RD Receive Data (from DDIU) 
4 RTS Request to Send (to DDIU) 
5 CTS Clear to Send (from DDIU) 
6 DSR Data Set Readv (from DDIU) 
1 7 1 SG 1 Sianal Ground/Common Return 
1 
1 8 (RCDI Receive Carrier Detect (from DDIU) 
1 
1 15 /ST21 Transmission Signal Element Timing 
(from DDIU) I 
, 7 RT Transmission Signal Element Timing...

Page 52

INSTALLATION INSTRUCTIONS 
SECTION 200-255-204 
FEBRUARY1992 
5.87 Switches 2,3, and 4 select the data speed for 
synchronous transmission only. 
Switch 2 = 2400 bps 
Switch 3 = 4800 bps 
Switch 4 = 9600 bps 
5.88 If asynchronous operation is used, the 
switches will have no effect and the data speed will 
self-adjust to a maximum speed of 19.2 kbps or 
less. 
5.89 A power ON/OFFswitch that appears on some 
early DDIU-MAT models controls power to the 
DDIU-MAT from the power supply. If the switch is...

Page 53

LOOSEN 
I-  
LOOSEN’ 
FIGURE 4-40-DDIU-MA DNA PCB 
2) Carefully separate the two halves of the DDIU- 
MA to expose the S2 and S3 (DTE/MODEM) 
switches (Figure 4-41) in the upper left corner 
of the DIUB PCB. 
3) If the DDIU-MA is to be connected to a DTE, 
both switches must be in the DTE position. If 
it will be connected to a DCE, both switches 
must be in the MODEM position. 
4) Reassemble the DDIU-MA. 
5.96 See Operating Procedures or DDIU-MA and 
Electronic Telephone User Guides for information 
on...

Page 54

INSTALLATION INSTRUCTIONS 
SECTION 200-255-204 
FEBRUARY 
1992 
DTE Position: 
Pin No. Desianation 6. DIGITAL TELEPHONE STATION 
EQUIPMENT INSTALLATION 
1 FG Protective Ground/Frame 
2 SD Transmitted Data (to DDIU) 6.00 Digital Telephone Connections 
1 8 ( RD ) Receive Data (from DDIU) 
I 
4 RTS Request to Send (to DDIU) 
5 CTS Clear to Send (from DDIU) 
6 DSR Data Set Ready (from DDIU) 
7 SG Signal Ground/Common Return 
8 RCD Receive Carrier Detect (from DDIU) 
,5 ST2 Transmission Signal Element Timing...

Page 55

INSTALLATION INSTRUCTIONS 
SECTIONZOO-255-204 
FEBRUARY1992 
NOTE: 
Digital Telephones with Data Interface Units (PDIU-DI) or Off-hook Cal/Announce (DVSU), and Stand- 
a/one Data Interface Units (PDIU-DS) are connected, per Figure 4-42, using single-pair wiring. 
NDKU PCB 
I PCB CONNECTOR 
26 
1 
27 
2 
28 
3 
29 
4 
30 
5 
31 
6 
-I TL4 I l 
DI ” I I I 32 I- 
I I La 
I 
-. - 1 34 l- 
I 
I I 
I I 37 
l-I 7 I I 
I k 12 
I I 
I 15 l- 
(W-BL) 
(BL-W) 
(W-0) 
(0-W) 
(W-G) 
G-W) 
(W-BR) 
(BR-W) 
W-S) - TLl 
-...

Page 56

INSTALLATION INSTRUCTIONS 
SECTION 200-255-204 
FEBRUARY 1992 
6.12 Loosen the four captive screws securing the 
digital telephone’s base, and remove the base 
(Figure 4-43). 
6.13 Using a cutter, remove the handset hanger 
from the base. Insert the handset hanger in the slot 
provided on the front of the telephone (Figure 4- 
44). The hanger fits in the notch on the handset. 
6.14 Rotate the mounting base 180” and secure to 
the telephone with the four captive screws (Figure 
4-45). 
6.15 Connect the...

Page 57

telephone, and the NDKU must be set for option 2 
(see Paragraph 3.45 of this chapter). 
6.22 A DVSU PCB inside a lOOO-series digital 
telephone allows the digital telephone to receive 
the Off-hook Call Announce feature. 
NOTE: 
It is not recommended to equip digital tele- 
phones with both Off-hook Cal/Announce and 
the headset option at the same time. 
6.23 The installation of the DVSU PCB must be 
done in accordance with the following steps: 
1) Loosen the four captive screws securing the...

Page 58

INSTALLATION INSTRUCTIONS 
SECTION 200-255-204 
FEBRUARY1992 
2) Refer to Figure 4-47, and locate the CARBON 
straps, W301 and W302, and cut them. 
3) Reinstall the telephone base (Figure 4-43), 
and secure it with its four captive screws. 
6.40 Beep Strap Removal 
6.41 A beep is emitted whenever a dialpad button 
or flexible button is pressed. This beep can be 
eliminated if the beep strap is cut. To cut the strap: 
1) Loosen the four captive screws securing the 
telephone’s mounting base (Figure 4-43),...

Page 59

7) Refer to Figure 4-47, and locate the HHEU 
strap, W303, on the upper PCB. Cut the strap 
if the HHEU PCB is to be connected to a 
headset. 
8) Reinstall the telephone’s mounting base and 
secure it with its four captive screws. 
6.70 Attendant Console Connection 
6.71 See Paragraph 5.50 for the attendant console 
connection. 
6.80 DSS Console Connections 
6.81 See the DSS Program in Section 200-255- 
300, Programming, to input information concern- 
ing the digital DSS consoles. 
6.82 The DSS console...

Page 60

INSTALLATION INSTRUCTIONS 
SECTlON200-255-204 
FEBRUARY1992 
NDKU PCB CONNECTOR 
t MODULAR JACK STATION CORD 
- TLl - 26 - W-EL 
CKT - RLl - 1 - BL-W 
1 
- DTLl - 27 - W-O 
- DRLl - 2 - O-W 
- TL2 - 20 - W-G 
CONSOLE #l 
CKT - RLZ! - 3 - G-W 
2 
- DTL2 - 29 - W-BR 
- DRL2 - 4 - BR-W 
- TL3 - 30 - W-S 
CKT - AL3 - 5 - s-w 
3 
- DTL3 - 31 - R-BL 
CONSOLE #3 
- DRL3 - 6 - BL-R 
- TL4 - 32 - R-O 
CKT - RL4 - 7 - O-R 
4 
- DTL4 - 33 - R-G 
CONSOLE #4 
- DRL4 - 0 - G-R 
FIGURE 4-49-DIGITAL DSS CONSOLE...
Start reading Toshiba Perception E Ex Digital Pbx Installation And Maintenance Manual

Related Manuals for Toshiba Perception E Ex Digital Pbx Installation And Maintenance Manual

All Toshiba manuals