    2. PRINTER SETUP ENGLISH VERSION EO1-33055 
    2.12 Position and Print Tone Fine Adjustment
     
    E2-58 
    2.12  Position and Print  Tone Fine 
    Adjustment (Cont.) 
     
     
       
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    After selecting a fine adjustment value, press the  [PAUSE] key. 
     
     
    Reverse Feed Amount Fine Adjustment 
    NOTES: 
    Choose a desired value by using the
    [RESTART] or [FEED] key.  
    Pressing the [FEED] key one time
    causes a –0.1mm change, up to  
    –9.9 mm. 
    Pressing the [RESTART]  key one
    time causes a +0.1mm change, up
    to +9.9 mm
    . 
    •  Example of Reverse Feed Amount Fine Adjustment 
     
      When setting +3.0 mm  
      Compared with “+0.0mm” position, the print start position  after a reverse feed is shifted forward. 
     
     
     
     
      When setting +0.0 mm
     
      
     
     
     
     
      When setting –3.0 mm
     
      Compared with “+0.0mm” position, the print start position  after a reverse feed is shifted backward.  
     
    [RESTART]
    [FEED]
    BACK ADJ.+9.9mm 
    BACK ADJ.+9.8 mm 
    BACK ADJ.+0.0mm 
    BACK ADJ.-9.8mm 
    BACK ADJ.-9.9mm 
    BACK ADJ.-0.1mm 
    BACK ADJ.+0.1mm 
    BACK ADJ. +5.0mm  
    3mm
    Print Start Position after a 
    reverse feed 
    Print Start Position after a 
    reverse feed 
     
    3mm
    Feed Direction
    Feed Direction Print Start Position after a 
    reverse feed  
    Feed Direction 
    						
    							
    2. PRINTER SETUP ENGLISH VERSION EO1-33055 
    2.12 Position and Print Tone Fine Adjustment
     
    E2-59 
    2.12  Position and Print  Tone Fine 
    Adjustment (Cont.) 
     
     
     
     
     
     
     
       
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    After selecting a fine adjustment value, press the 
    [PAUSE] key. 
     
     
     
     
     
     
     
    X Coordinate Fine Adjustment
    NOTES: 
    Choose a desired value by using the
    [RESTART] or [FEED] key.  
    Pressing the [FEED] key one time
    causes a –0.1mm change, up to  
    –99.9 mm. 
    Pressing the [RESTART]  key one
    time causes a +0.1mm change, up
    to +99.9 mm
    . 
    •  Example of X Coordinate Fine Adjustment 
     
      When setting –50.0 mm  
      Compared with “+0.0mm” position, the print position  is shifted to the left. 
     
     
     
     
      When setting +0.0 mm
     
      
     
     
     
     
      When setting +50.0 mm
     
      Compared with “+0.0mm” position, the print position  is shifted to the right.  
     
    X ADJUST +5.0mm  
    [RESTART]
    [FEED]
    X ADJUST +99.9mm 
    X ADJUST +99.8mm 
    X ADJUST +0.0mm 
    X ADJUST -99.8mm 
    X ADJUST -99.9mm 
    X ADJUST -0.1mm 
    X ADJUST +0.1mm 
     
    ABC 
    Feed Direction 
     
    ABC 
     
                 ABC 
    50.0mm
    50.0mm
    Top Down Printing
    X 
    Y 
    Bottom First Printing
    X 
    Y  
    						
    							
    2. PRINTER SETUP ENGLISH VERSION EO1-33055 
    2.12 Position and Print Tone Fine Adjustment
     
    E2-60 
    2.12  Position and Print  Tone Fine 
    Adjustment (Cont.) 
     
     
     
     
     
     
     
     
       
     
     
      Thermal Transfer Print  
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    After selecting a fine adjustment valu e or to skip this menu, press the 
    [PAUSE]  key. 
     
     
     
      Thermal Direct Print  
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    After selecting a fine adjustment valu e or to skip this menu, press the 
    [PAUSE]  key. 
     
     
     
     
     
    Print Tone Fine Adjustment 
    NOTES: 
    Choose a desired value by using the
    [RESTART] or [FEED] key.  
    Pressing the [FEED] key one time
    causes a –1 tone change, up to  
    –10 tones. 
    Pressing the  [RESTART]  key one
    time causes a +1 tone change, up to
    +10 tones
    . 
    TONE ADJ. +3  
    [RESTART]
    [FEED]
    TONE ADJ. +10 
    TONE ADJ. +9 
    TONE ADJ. +0 
    TONE ADJ. -9 
    TONE ADJ. -10  Darker
    Lighter
    Standard
    TONE ADJ. +10 
    TONE ADJ. +9 
    TONE ADJ. +0 
    TONE ADJ. -9 
    TONE ADJ. -10 
    [RESTART]
    [FEED] Darker
    Lighter
    Standard
    TONE ADJ. -2   
    						
    							
    2. PRINTER SETUP ENGLISH VERSION EO1-33055 
    2.12 Position and Print Tone Fine Adjustment
     
    E2-61 
    2.12  Position and Print  Tone Fine 
    Adjustment (Cont.) 
     
     
     
     
     
       
     
    When the ribbon is slack or wrinkled a nd printing is affected, fine adjust 
    the ribbon motor torque by using the following procedure. 
     
     
    Take-up Motor (RBN ADJ ) 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    After selecting a fine adjustment valu e or to skip this menu, press the 
    [PAUSE]  key. 
     
     
     
     
    Feed Motor (RBN ADJ ) 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    After selecting a fine adjustment valu e or to skip this menu, press the 
    [PAUSE]  key. 
     
     
    Ribbon Motor Voltage Fine Adjustment 
    [RESTART]
    [FEED]
    RBN ADJ +6 
    RBN ADJ +5 
    RBN ADJ +4 
    RBN ADJ -14 
    RBN ADJ -15 
    Motor Torque
    High 
    Low 
    RBN ADJ -10  
    RBN ADJ +10 
    RBN ADJ +9 
    RBN ADJ +8 
    RBN ADJ -14 
    RBN ADJ -15 
    Motor Torque
    High 
    Low 
    [RESTART]
    [FEED]
    RBN ADJ -5  
    NOTES: 
    Choose a desired value by using the
    [RESTART] or [FEED] key.  
    Pressing the [FEED] key one time 
    causes a –1 step change, up to  
    –15 steps. 
    Pressing the [RESTART]  key one 
    time causes a +1 step change, up to
    +6 steps
    . 
    NOTES: 
    Choose a desired value by using the
    [RESTART] or [FEED] key.  
    Pressing the [FEED] key one time 
    causes a –1 step change, up to  
    –15 steps. 
    Pressing the [RESTART]  key one 
    time causes a +1 step change, up to 
    +10 steps
    .  
    						
    							
    2.PRINTER SETUP ENGLISH VERSION EO1-33055 2.13 Threshold Setting
     
    E2-62 
    2.13 Threshold Setting 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
      To maintain a constant print position 
    the printer uses the media sensor to 
    detect a print start position according to the difference of voltage between 
    a print area and a gap or black mark.  When the media is pre-printed, the 
    darker (or more dense) inks can inte rfere with this process causing paper 
    jam errors. 
    To get around this problem, first, try an automatic threshold setting.   
    If the problem still occurs, then, th e threshold voltage needs to be 
    manually set.  
     
     
     
     
    1.  Turn the power ON.  The printer is in online mode. 
    2.   Load a pre-printed media roll. 
      When using a label stock, move the Feed Gap Sensor so that it is in  line with the centre of the label.   
      When using a tag stock, move the Black Mark Sensor so that it is in  line with the centre of a black mark. 
    3.  Press the  [PAUSE] key. 
    4.   The printer enters the pause mode. 
    5.   Press and hold the  [PAUSE] key in the pause state until the following 
    screen appears. 
    6 .  The sensor type is displayed. 
     
     
    7.   Select the sensor to be adjusted by using the  [FEED] key. 
     
     
     
     
     
    8.   Press and hold the  [PAUSE] key until more than 1.5 labels (tags) 
    have been issued.   
      The media will continue to be fed until the  [PAUSE] key is released.  
    (An automatic threshold setting for  the selected sensor is completed 
    by this operation.) 
     
     
     
    9.  Press the  [RESTART]  key. 
     
     
     
    10.   The printer returns to online mode. 
      Send an issue command from the host computer to the printer.  
     
    NOTES: 
    1. Failure to feed more than 1.5 labels may result in an incorrec
    t
    threshold setting. 
    2.  While the Top Cover is raised, the 
    [PAUSE] key does not work 
    3.  A paper end error cannot be 
    detected during paper feed.  
    Automatic threshold setting procedure  
    REFLECTIVE  TRANSMISSIVE  
    Black mark sensor  Feed gap sensor 
    [FEED]
    TRANSMISSIVE  
    ON LINE 
    PAUSE  
    						
    							
    2.PRINTER SETUP ENGLISH VERSION EO1-33055 2.13 Threshold Setting
     
    E2-63 
    2.13 Threshold Setting  (Cont.) 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
       
     
    If a paper jam error still occurs even 
    after an automatic threshold setting 
    has been performed, manually set the threshold voltage.   
     
    To make a threshold value manually set in this section effective, select 
    the Transmissive Sensor (when us ing manual threshold value) or 
    Reflective Sensor (when using manual  threshold value) within software 
    commands or the printer driver.   
     
    1.  While holding down the  [FEED] and  [PAUSE]  keys, turn on the 
    printer. 
    2.   When “DIAG.” appears on the  LCD Message Display, release the 
    [FEED]  and  [PAUSE]  keys. 
     
     
     
      Now, the printer is in the System Mode for system administrators. 
     
    3.  Press the  [FEED] or [RESTART]  key until “SENSOR ADJ.” 
    appears on the LCD Message Display.  
     
     
     
    4.  Press the  [PAUSE] key to enter the Sensor Adjustment Mode. 
     
     
     
    The Sensor Adjustment Mode contains sub menus for displaying the 
    current status of each sensor and for storing “media level” voltage and 
    “no media level” voltage.  Each time the  [PAUSE] key is pressed, the 
    sub menus are displayed sequentially. 
     
      (1)  Sensor Status Display: 
        Temperatures being detected by the Print Head Thermistor and  the Ambient Thermistor are displayed. 
      (2)  Upper Black Mark Sensor Status Display: 
        Voltage being detected by the upper Black Mark Sensor is  displayed.  
      (3)  Upper Black Mark Sensor Adjustment: 
        Using the media actually used, a “media level” voltage is stored. 
      (4)  Lower Black Mark Sensor Status Display: 
        Voltage being detected by the lower Black Mark Sensor is  displayed.  
      (5)  Lower Black Mark Sensor Adjustment: 
        Using the media actually used, a “media level” voltage is stored.  
      (6)  Feed Gap Sensor Status Display: 
        Voltage being detected by the Feed Gap Sensor is displayed.  
      (7)  Feed Gap Sensor Adjustment: 
        Using the media actually used, a “media level” voltage is stored. 
      (8)  Lower Black Mark Sensor/Feed Gap Sensor Status Display  (No media): 
        “No media level” voltage detected by the lower Black Mark  Sensor/Feed Gap Sensor is displayed.  
      (9)  Lower Black Mark Sensor/F eed Gap Sensor Adjustment (No 
    media): 
        “No media level” voltage is stored.  
     
    Manual threshold setting procedure
    [PAUSE] 
     [H]28 °C  [A]28 °C 
     [REF. ] 3.5V 
     [REF. ] 4.8V* 
     [TRANS.] 2.4V 
     [TRANS.] 4.1V* 
     [PE]R0.1V T4.8V 
     [PE]R0.1V T4.8V* 
    SENSOR ADJ. 
    [PAUSE] 
    [FEED]  or [RESTART] 
    [PAUSE] 
    [FEED]  or [RESTART] 
    [PAUSE] 
    [PAUSE] 
    [FEED]  or [RESTART] 
     [REF. ]  4.8V 
     [REF. ]  4.8V* 
    [PAUSE] 
    [FEED]  or [RESTART] 
    SENSOR ADJ. 
    [H]28 °C  [A]28 °C 
    DIAG.  
    						
    							
    2.PRINTER SETUP ENGLISH VERSION EO1-33055 2.13 Threshold Setting
     
    E2-64 
    2.13 Threshold Setting  (Cont.) 
     
     
     
      „
     When using the Black Mark Sensor  
    (1) While “SENSOR ADJ.” is displayed, press the  [PAUSE] key 
    until the message appears.  
      The displayed value is a real-time voltage being detected by the Black  Mark Sensor. 
     
     
     
    (2) Measure a voltage at a blank part of media and a black mark, 
    respectively.  At this time, write down the midpoint between both 
    voltages. (This value is used later for a threshold setting.) 
     (Example)  Print area = 4.8V, Black mark = 2.4V    Midpoint = 3.6V 
     
     
     
     
     
     
     
     
     
     
    (3) Press and hold the  [RESTART] or [FEED]  key for about 3 seconds 
    aligning a blank part of print area with the Black Mark Sensor. 
     
    (4) When storing a “media level” volta ge is completed, an asterisk “*”is 
    displayed on the right side of a voltage.  Press the  [PAUSE] key. 
     
    (5) A real-time voltage being detected by the Feed Gap Sensor is  displayed.  
     
     
    „   When using the Feed Gap Sensor 
    (1)Measure a voltage at a blank part of label and a label gap, respectively.   At this time, write down the midpoint of both voltages. (This value is 
    used later for a threshold setting.) 
     (Example)  Print area = 2.4V, Gap = 4.0V    Midpoint = 3.2V 
     
     
     
     
     
     
     
     
     
     
    (2) Press and hold the  [RESTART] or [FEED]  key for about 3 seconds 
    aligning a blank part of print area with the Feed Gap Sensor. 
     
    (3) When storing a “media level” volta ge is completed, an asterisk “*”is 
    displayed on the right side of a voltage.  Press the  [PAUSE] key.   
     
    (4) The display changes as shown on the left.  
    NOTES: 
    1.  When measuring a voltage of a blank area, be careful not to align a pre-print with the sensor by mistake. 
    2.  Confirm that there is at least 0.7V difference between the two values.
    If the difference in voltage is less than 0.7V, a print start position
    cannot be detected.  In that case, please consider changing the media
    type.  
    3.  Make sure that the Top Cover is closed when measuring the voltages.
     [REF. ] 3.5V 
     [REF. ] 4.8V* 
     [TRANS.] 2.4V 
    NOTES: 
    1.  When measuring a voltage at a blank area, be careful not to align a pre-print with the sensor by mistake. 
    2.  Confirm that there is at least 0.7V difference between the two values. If the difference in voltage is less than 0.7V, a print start position
    cannot be detected.  In that case, please consider changing the media
    type.  
    3.  Make sure that the Top Cover is closed when measuring the voltages.
     [TRANS.] 2.4V 
     [TRANS.] 2.4V* 
     [PE]R0.1V  T4.8V 
    Voltage at a black mark 
    Voltage at a print area 
    Midpoint (Threshold voltage) 
    Voltage at a label gap 
    Voltage at a print area 
    Midpoint (Threshold voltage) 
    [REF. ] 3.5V  
    						
    							
    2.PRINTER SETUP ENGLISH VERSION EO1-33055 2.13 Threshold Setting
     
    E2-65 
    2.13 Threshold Setting  (Cont.) 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    „ Storing a “No Media Level” Voltage  
    The following is how to set a “No medi a level” voltage that is used to 
    detect a paper end.   
    If a “NO PAPER” is displayed even if the media has not run out yet, this 
    voltage needs to be set again.  
     
    (1) Remove any media from the Black Mark Sensor/Feed Gap Sensor.  
     
    (2) A real-time voltages being detected by the lower Black Mark Sensor  and Feed Gap Sensor are displayed. 
     
     
     
     
     
     
    (3) Press and hold the  [RESTART] or [FEED]  key for about 3 seconds. 
     
     
     
    (4) When storing a “no media level” voltage is completed, an asterisk  “*”is displayed on the right si de of a voltage.  Press the [PAUSE] key. 
     
    (5) The message returns to “SENSOR ADJ.”.  
     
     
     
     
     
    „  Manual Threshold Setting  
    Then, set the calculated threshold voltage in the Parameter Fine 
    Adjustment mode. 
     
    (1) While “SENSOR ADJ.” is displayed, press the  [FEED] or 
    [RESTART]  key until “ADJUST SET” is displayed.  
     
     
     
    (2)Press the  [PAUSE] key to enter the Parameter Fine Adjustment Mode. 
     
     
     
    Feed Gap Sensor
    Lower Black Mark Sensor 
    FEED ADJ.+10.0mm 
    ADJUST SET 
     [PE]R0.1VT4.8V*  
    SENSOR ADJ.  
     [PE]R0.1V  T4.8V  
    						
    							
    2.PRINTER SETUP ENGLISH VERSION EO1-33055 2.13 Threshold Setting
     
    E2-66 
    2.13 Threshold Setting  (Cont.) 
     
     
     
     
     
     
     
     
     
     
     
      (3) Press  the 
    [PAUSE] key until the target sensor type is displayed.  
     
     
     
     
     
     
     
    (4) Set a threshold voltage (calculate d in Sensor Adjustment Menu) by 
    using the  [FEED] or [RESTART]  key, as shown below.  
     
      Threshold voltage =  Midpoint between voltage at a print area and 
    voltage at a gap/black mark 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    (5) After choosing a threshold voltage, press the  [PAUSE] key.  
     
    (6) To check for a proper operation, issu e the pre-printed media in online.  
      If an error still occurs even afte r a manual threshold setting, change 
    the threshold voltage a little, and retry. 
     
     
     
    NOTE: 
    Pressing the  [FEED] key one time 
    causes a –0.1V change, up to 0.0V. 
    Pressing the  [RESTART]  key one 
    time causes a +0.1V change, up to 
    +4.0V.  Black Mark Sensor  
    Feed Gap Sensor 
    [RESTART] 
    [FEED]
    THRESHOLD4.0V 
    THRESHOLD3.9V 
    THRESHOLD3.8V 
    THRESHOLD0.1V 
    THRESHOLD0.0V 
    Black Mark Sensor 
    THRESHOLD4.0V 
    THRESHOLD3.9V 
    THRESHOLD3.8V 
    THRESHOLD0.1V 
    THRESHOLD0.0V 
    Feed Gap Sensor 
    [PAUSE]
    THRESHOLD1.4V 
    THRESHOLD1.0V  
    						
    							3. ON LINE MODE ENGLISH VERSION EO1-33055 
    3.1 Operation Panel 
     
    E3- 1 
    3.  ON LINE MODE 
     
     
     
     
     
    3.1 Operation Panel 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    This chapter describes usage and purpose of the keys on the Operation 
    Panel in On Line Mode.  
    When the printer is in On Line Mode and connected to a host computer, 
    normal operation of printing images on labels or tags can be 
    accomplished.  
     
     
     
    • The figure below illustrates the Operation Panel and key functions.  
     
     
     
     
     
    The LCD Message Display shows messages in alphanumeric characters 
    and symbols to indicate the printer’s status.  Up to 16 characters can be 
    displayed on one line.  
     
    There are three LED lights on the Operation Panel.    
    LED  Illuminates when…  Flashes when… 
    POWER The printer is turned on.  ----- 
    ON LINEThe printer is ready to 
    print. The printer is 
    communicating with 
    your computer. 
    ERROR Any error occurs with 
    the printer. ----- 
     
    There are three keys on the Operation Panel.  
    PAUSE Used to stop printing temporarily. 
    RESTART Used to restart printing.  
    FEED Used to feed the media.  
     
    NOTE: 
    Use the 
    [RESTART] key to 
    resume printing after a pause 
    condition, or after clearing an 
    error. 
    LCD Message Display 
    ON LINE LED
    (Green) 
    ERROR LED
    (Red) 
    [PAUSE] key POWER LED
    (Green)[FEED] key
    [RESTART] key 
    						