524 Configuration Sheet
DSS Keys
DSS keys are numbered vertically on the console.
DSS
KEYSTATION
NUMBERUSER NAMEDSS
KEYSTATION
NUMBERUSER NAME
1
FD4710 John F13FD4737 Phillip R
2FD4719 Bill Jones14FD4736 Mary S
3FD4729 Jill K15FD4723 Steven E
4FD4711 Jane W16FD4713 Karen G
5FD4712 Ronnie Y17FD4714 Robert T
6FD4715 Kim L18FD4724 Jim W
7FD4720 Jack S19FD4725 Pat K
8FD4716 William F20FD4726 Randy A
9FD4717 Sarah S21FD4727 Kirk B
10FD4718 Robin R22FD4728 Cliff M
11FD4721 John L23FD4730 Paul C
12FD4722 Bill...

Page 12

Installation
Contents of Shipping Boxes
The Tone Commander 524 system is shipped in two boxes: one for the console, and one for the central
processing unit (CPU). Please compare the contents of these boxes with the lists below. Contact your
distributor if any items are missing or damaged.
Console Box:
(1) console
(2) 7´ line cords
(1) handset with cord
(1) handset cradle
(2) cradle mounting screws
(1) Attendant’s Guide
(1) Quick Reference Card
(1) bag of clear keycaps
(1) sheet of keycap labels
CPU Box:...

Page 13

CPU Installation
Mounting CPU and Blocks
Refer to Figure 5.
1. Fasten a plywood sheet to the wall with hardware suitable for the wall material.
2. Using the supplied mounting template, mark and pre-drill the mounting holes for the CPU.
Make sure that the CPU mounting location is within 5 feet of a standard 117 VAC, 60 Hz grounded
power outlet.
Allow at least one foot of free space above and below the CPU for ventilation.
3. Drive in four suitable fasteners (such as #10×¾ pan head tapping screws), leaving...

Page 14

Reference Grounding
CPU Chassis Grounding
This ground connection is required for safety and EMI shielding. It is usually provided by the 3rd wire on
the CPU power cord. If the integrity of the power outlet ground is questionable, use the ground connection
shown below for the 524 CPU.
1. Connect a solid copper #10 or #12 AWG wire to the ground terminal on the CPU. The wire should be
tightly clamped between the ground screw and the cup washer.
2. Connect the wire to an approved ground, such as MGN...

Page 15

Connections to Telco/PABX Lines
Line Testing
Connect a test telephone to each line; verify the presence of dial tone, and break dial tone by dialing a
number.
The 524 allows DTMF tone dialing only – refer to the Telco/PABX Requirements
section.
Test any additional features ordered with the lines. Open circuit voltage must be approximately 48 volts.
Station Connections
Station Monitoring
13-102408 Rev. HPage 15
Tone Commander 524 Installation Instructions
1. Connect Tip and Ring of each line to the...

Page 16

Page 1613-102408 Rev. H
Tone Commander 524 Installation Instructions
Figure 5 

Page 17

CONNECTOR #1
PIN NO.
WIRE COLOR(left side of block unused)DESIGNATION(right)
26·······WHT-BLU······· – ··········1TN
1·······BLU-WHT······· – ··········1RN
27·······WHT-ORN······· – ··········1C1
2·······ORN-WHT······· – ··········1C2
28·······WHT-GRN······· – ··········1C3
3·······GRN-WHT······· – ··········1C4
29·······WHT-BRN······· – ··········2TN
4·······BRN-WHT······· – ··········2RN
30·······WHT-SLT ······· – ··········2C1
5·······SLT-WHT ······· – ··········2C2
31·······RED-BLU······· –...

Page 18

CONNECTOR #2 CONNECTOR #3
PIN NO.
WIRE COLORDESIGNATION(left)DESIGNATION(right)
26·······WHT-BLU·······T1···········T16
1·······BLU-WHT·······R1···········R16
27·······WHT-ORN·······T2···········T17
2·······ORN-WHT·······R2···········R17
28·······WHT-GRN·······T3···········T18
3·······GRN-WHT·······R3···········R18
29·······WHT-BRN·······T4···········T19
4·······BRN-WHT·······R4···········R19
30·······WHT-SLT ·······T5···········T20
5·······SLT-WHT ·······R5···········R20...

Page 19

Console Cable Installation
Wall
Jack
PinoutWall Jack
Typical
Wire ColorConsole #1
Designation
(connector 1)Console #2
Designation
(connector 1)Typical 3 Pair
Console Cable
Wire Color(actual
wire color)
1 WHT 1C3 (WHT-GRN) 2C3 (RED-BLU) WHT-GRN
2 BLK 1C1 (WHT-ORN) 2C1 (WHT-SLT) WHT-ORN
3 RED 1RN (BLU-WHT) 2RN (BRN-WHT) BLU-WHT
4 GRN 1TN (WHT-BLU) 2TN (WHT-BRN) WHT-BLU
5 YEL 1C2 (ORN-WHT) 2C2 (SLT-WHT) ORN-WHT
6 BLU 1C4 (GRN-WHT) 2C4 (BLU-RED) GRN-WHT
Table 3– Console “Voice/Data” Jack Pinout
13-102408...

Page 20

Wall
Jack
PinoutWall Jack
Typical
Wire ColorConsole #1
Designation
(connector 1)Console #2
Designation
(connector 1)Typical 3 Pair
Console Cable
Wire Color(actual
wire color)
1 WHT 1C+ (YEL-BRN) 2C+ (VIO-GRN) WHT-GRN
2 BLK 1C+ (YEL-GRN) 2C+ (VIO-ORN) WHT-ORN
3 RED 1C- (ORN-YEL) 2C- (BLU-VIO) BLU-WHT
4 GRN 1C+ (YEL-ORN) 2C+ (VIO-BLU) WHT-BLU
5 YEL 1C- (GRN-YEL) 2C- (ORN-VIO) ORN-WHT
6 BLU 1C- (BRN-YEL) 2C- (GRN-VIO) GRN-WHT
Table 4– Console “Power” Jack Pinout
The total console cable length, including...