Page 31
427-0011-00-10 Revision 140 Copyright © FLIR Systems, Inc. 31 Your 35x140MS camera images through a lens that is made from material that is transparent to long-wave infrared energy. This lens is designed for the harsh outdoor environment and has a coating for durability, but may require occasional cleaning. FLIR Systems Inc. suggests that you clean the lens when image quality degradation is noticed or excessive contaminant build-up is seen on the lens. The camera housing has a durable...
Page 32
427-0011-00-10 Revision 140 Copyright © FLIR Systems, Inc. 32 Noisy image A noisy image is usually attributed to a cable problem (too short or inferior quality) or the cable is picking up electromagnetic interference (EMI) from another device. Although coax cable has built-in losses, the longer and smaller the cable is, the more severe the losses become; and the higher the signal frequency, the more pronounced the losses. Unfortunately this is one of the most common and unnecessary problems...
Page 33
427-0011-00-10 Revision 140 Copyright © FLIR Systems, Inc. 33 8.0 35X140MS CAMERA SPECIFICATIONS Feature SR-35x140MS PTZ-35x140MS Weight 15 lb. (6.8 kg) 45 lbs (20.4 Kg) Dimensions Refer to detailed drawings below in the following section FPA size (HxV) 320x240 Sensor type Uncooled Microbolometer Spectral range 7.5 to 13μm Pixel pitch 38 microns Input power range 24 VDC ±10 % Voltages as measured at the input to the 24 VAC ±10 % electrical interface board....
Page 34
427-0011-00-10 Revision 140 Copyright © FLIR Systems, Inc. 34 o Focus Automatic o Iris Automatic o Shutter Automatic o Balance Automatic o IR cut filter Automatic o Image Stabilization o Digital Zoom o Spectral Response 400 to 750 nm with IR cut filter Infrared Camera Specifications: Wide FOV 20° 35mm Narrow FOV 5° 140mm Focal Plane Array Uncooled µbolometer Uncooled µbolometer Format 320 x 240 320 x 240 Pixel Size 38µm 38µm Aperture f/1.4 f/1.4 Field-of-view 20° HFOV...
Page 35
427-0011-00-10 Revision 140 Copyright © FLIR Systems, Inc. 35 8.2 PTZ-35x140 PHYSICAL Dimensions The following figures show a dimensioned drawing of the PTZ-35x140MS. Remember to firmly secure unit and allow for device travel.
Page 36
427-0011-00-10 Revision 140 Copyright © FLIR Systems, Inc. 36 Figure 8-1: PTZ-35x140MS Dimension Drawing (inches)
Page 37
427-0011-00-10 Revision 140 Copyright © FLIR Systems, Inc. 37 Figure 8-2: PTZ-35x140MS Dimension Drawing w/ hole pattern (inches)
Page 38
427-0011-00-10 Revision 140 Copyright © FLIR Systems, Inc. 38 SR-35x140MS Physical Dimensions The following figures show a dimensioned drawing of the SR-35x140MS. Figure 8-3: SR-35x140MS Dimension Drawing (inches)
Page 40
427-0011-00-10 Revision 140 Copyright © FLIR Systems, Inc. 40 8.3 System Interface Cable Connector The PTZ-35x140MS and SR-35x140MS use an electrical-mechanical engagement connection that requires only one integrated cable to interface with the sensor. An optional interface cable is available. It is 12.2 meters (40 ft) long and is terminated with a MIL-C-26482 Series 1 Connector. Figure 8-4: PTZ/SR-35x140MS Interface Cable Connector System Interface Cable Pin...