427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   31 
Your 35x140MS camera images through a lens that is made from material that is transparent to 
long-wave infrared energy. This lens is designed for the harsh outdoor environment and has a 
coating for durability, but may require occasional cleaning. FLIR Systems Inc. suggests that you 
clean the lens when image quality degradation is noticed or excessive contaminant build-up is 
seen on the lens.  
The camera housing has a durable...

Page 32

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   32 
Noisy image 
A noisy image is usually attributed to a cable problem (too short or inferior quality) or the cable 
is picking up electromagnetic interference (EMI) from another device. Although coax cable has 
built-in losses, the longer and smaller the cable is, the more severe the losses become; and the 
higher the signal frequency, the more pronounced the losses. Unfortunately this is one of the 
most common and unnecessary problems...

Page 33

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   33 
8.0 35X140MS CAMERA SPECIFICATIONS 
Feature SR-35x140MS  PTZ-35x140MS 
Weight  15 lb. (6.8 kg)  45 lbs (20.4 Kg) 
Dimensions  Refer to detailed drawings below in the following section 
FPA size (HxV)  320x240 
Sensor type  Uncooled Microbolometer 
Spectral range  7.5 to 13μm 
Pixel pitch  38 microns 
Input power 
range 24 VDC ±10 %          Voltages as measured at the input to the  
24 VAC ±10 %           electrical interface board....

Page 34

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   34 
o Focus Automatic 
o Iris Automatic 
o Shutter Automatic 
o Balance Automatic 
o  IR cut filter Automatic 
o Image Stabilization  
o Digital Zoom 
o  Spectral Response 400 to 750 nm with IR cut filter 
 
Infrared Camera Specifications: 
 
 Wide FOV 20° 35mm Narrow FOV 5° 140mm 
Focal Plane Array  Uncooled µbolometer  Uncooled µbolometer 
Format  320 x 240  320 x 240 
Pixel Size  38µm  38µm 
Aperture f/1.4  f/1.4 
Field-of-view  20° HFOV...

Page 35

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   35 
8.2  PTZ-35x140 PHYSICAL Dimensions 
The following figures show a dimensioned drawing of the PTZ-35x140MS.  
Remember to firmly secure unit and allow for device travel. 
  

Page 36

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   36 
 
Figure 8-1: PTZ-35x140MS Dimension Drawing (inches) 
 
 
 
 
 
 
 
 
  

Page 37

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   37 
 
 
 
 
 
 
 
 
 
 
 
Figure 8-2: PTZ-35x140MS Dimension Drawing w/ hole pattern (inches)  

Page 38

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   38 
SR-35x140MS Physical Dimensions 
The following figures show a dimensioned drawing of the SR-35x140MS.  
 
 
Figure 8-3: SR-35x140MS Dimension Drawing (inches)  

Page 39

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   39 
 
 
  

Page 40

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   40 
8.3  System Interface Cable Connector  
The PTZ-35x140MS and SR-35x140MS use an electrical-mechanical engagement connection 
that requires only one integrated cable to interface with the sensor. An optional interface cable 
is available. It is 12.2 meters (40 ft) long and is terminated with a MIL-C-26482 Series 1 
Connector.   
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 8-4: PTZ/SR-35x140MS Interface Cable Connector 