427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   11 
3.0 INSTALLATION 
General installation information for both 35x140MS cameras is given below. If you have a 
question regarding installation or operation of your 35x140MS camera, contact FLIR Systems, 
Inc Customer Support, using the contact information at the front of this manual. Check out our 
training web site (http://www.flir.com/training/
) to get information on courses offered and to learn 
how you can become a FLIR-authorized...

Page 12

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   12 
Optional Accessories  
For installation purposes, the following optional accessories are available.   
  40 ft System Cable 308-0116-02  
  24VAC Power Supply 206-0004-01 
   Joystick 223-0017-00  
 
3.2 Camera Mounting 
Firmly secure the camera to a designated frame or structure capable of supporting the camera, 
using the mounting pattern shown below. For the PTZ-35x140MS, be sure to allow for device 
travel by providing a...

Page 13

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   13 
3.3 Camera Connections 
 
 
Connect the sealed System Cable to the connection on the camera base shown above. Then 
attach the other end of the System Cable to the Break-Out Connector Cable. The far end of the 
breakout cable must be protected from the weather. 
Ground Connection  
The 35x140MS cameras have grounding and surge protection to provide limited immunity from 
high current transients that can occur in installations subject to...

Page 14

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   14 
Optional Power Supply 
The connections labeled “PTPWR” and “SYSPWR” on the break-out cable can be directly 
connected to the optional power supply.  Connect the black leads to COM and the red leads to 
24V. Next, adjust the AC Input switch to either 115VAC (standard for US) or 230VAC (standard 
for Europe) and apply power to the power supply. 
Fuse Protection 
The optional power supply system is fuse-protected against over-voltage...

Page 15

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   15 
Serial control 
If you intend to use the Pelco “D” protocol interface for remote control of the device, attach a 
standard DB9 RS-422 cable to the connection labeled “USER P3” on the break-out pigtail.  
Connect the other end of the RS-422 cable to an available port on a remote control device such 
as a Pelco KBD300A. Note - the pins for receive and transmit signals are relative to the camera 
and must be swapped on the controller...

Page 16

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   16 
4.0  VERIFY CAMERA OPERATION 
Prior to installing the camera in its final location, use a bench test to verify camera operation 
and, if necessary, configure the camera for the local network.   
Power and analog video 
Connect the power to the camera as described above. Connect the video cable from the 
camera to a display/monitor. Turn on the camera and verify that video is displayed on the 
monitor.  
If serial communications is used,...

Page 17

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   17 
 
It is not necessary to log in and make changes with the Web Configuration tool right away. 
Refer to the following chapter for more information regarding camera configuration. At this time, 
it is recommended a bench test of the camera should be performed with the FLIR Sensors 
Manager software using the factory configuration and the default IP address. 
4.1  Bench Test Using FLIR Sensors Manager (FSM) 
The following provides a brief...

Page 18

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   18 
 
Initially the FLIR Sensors Manager splash screen will be displayed. The software version may 
be different than the version displayed below. 
 
After a brief while, the FSM main window will appear, and a popup FSM Notification window will 
appear in the lower right of the screen indicating that no cameras (servers) have been 
discovered yet. Click on the Accept button to acknowledge the notification. 
 
The FLIR Sensors Manager uses a...

Page 19

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   19 
 
Click 

Page 20

427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   20 
If necessary, click on the Discovery tab along the right side of the window. When the Discovery 
Panel is displayed, click Refresh. 
 
The FLIR camera will appear in the list of Discovered Servers. The asterisk in parenthesis “(*)” 
indicates the camera has not been added to the list of Active Servers on the right.  
Click on the center bar “>” to move the camera over to the list of Active Servers on the right. 
Once the camera has been...
Start reading ThermovisionFLIR PTZ35x140 MS Installation and Operation Manual