Home
>
Telrad Digital
>
Communications System
>
Telrad Digital DIGITAL Family Of Systems Administration, Installation And Upgrade Addendum Manual
Telrad Digital DIGITAL Family Of Systems Administration, Installation And Upgrade Addendum Manual
Here you can view all the pages of manual Telrad Digital DIGITAL Family Of Systems Administration, Installation And Upgrade Addendum Manual. The Telrad Digital manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 11
Section 1: INTRODUCTION 1-3 Universal Data Card manual (Catalog No. 79-125-0410/E) con- tains a description of the Universal Data Card and describes the hardware installation, software configuration, operation and applica- tions of the card. Feature description addendum (Catalog No. 76-110-0690/G) con- tains a detailed explanation of the system features and services that are new to Release 7 of the DIGITAL KEY BX and DIGITAL 400 sys- tems. Operating instructions (Catalog No. 76-110-0165/G) provides...
Page 13
2-1 Section 2 INSTALLATION2.1GENERAL The installation of Release SB7/DB7 DIGITAL systems is the same as that of Release SB6/DB6, except for those features described in this addendum. Refer to the Release SB6/SB7 DIGITAL Installation manual. NOTE There is no technician station in Release SB7/DB7 DIGITAL systems.2.2ULD AND UHD CARDS The ULD card provides an interface between the system and Avanti telephone sets and their add-ons (DSS consoles, SLTs, or RS232 data cards). There is no limit on the...
Page 14
76-110-0175/G, Issue 2 2-2ULD power limitation •Maximum 5 watt for 5V •Maximum 110 watt for 48V It is recommended that unused ULD ports be the last ports on the card. RS232 connector The ULD card has an RS232 socket for connection to a PC. The pins are the same as for an ELD card (RX TX GND). The RS232 port sup- ports 19200 bps. LEDs There is a LED on the ULD card for the ULD controller. The indica- tions are as follows: •steady red - from the time that the card is plugged in until the ini- tialization...
Page 15
Section 2: INSTALLATION 2-3 Table 2-1: ULD card MDF connector J2 Pin No. Port No.Port Function 1P1U+ 2P2U+ 3P3U+ 4P4U+ 5P5U+ 6P6U+ 7P7U+ 8P8U+ 9P9U+ 10P10U+ 11P11U+ 12P12U+ 13P13U+ 14P14U+ 15P15U+ 16P16U+ 17SPARESPARE 18P1GROUND 19P2GROUND 20P3GROUND 21P4GROUND 22P5GROUND 23P6GROUND 24P7GROUND 25P8GROUND 26P1U- 27P2U- 28P3U- 29P4U- 30P5U- 31P6U- 32P7U- 33P8U- 34P9U- 35P10U- 36P11U- 37P12U- 38P13U- 39P14U- 40P15U- 41P16U- 42SPARESPARE 43P1-48V 44P2-48V 45P3-48V 46P4-48V 47P5-48V 48P6-48V 49P7-48V 50P8-48V
Page 16
76-110-0175/G, Issue 2 2-42.3AVANTI TELEPHONE SETS AND OPTION MODULES 2.3.1Avanti telephone set configuration options Table 2-2 shows the maximum configuration distances for Avanti sets wired with 24 AWG wire. These distances are valid when the add-on units receive their power from the DIGITAL system’s power supply. NOTE When the add-on units are powered by an auxiliary power adapter, maximum distance is 1500meters for all configu- rations, except for the two-wire fully duplex station, which has a...
Page 17
Section 2: INSTALLATION 2-5 CoOperate card The CoOperate card uses a special protocol for PC applications, such as TSAPI. In PC application mode, data transfer is over the DIGITAL system’s D channel. This is the default work mode. Data is transferred from the PC application via the PC RS232, the data card RS232, the U bus D channel, the ULD card, and the sys- tem LAN toward any DIGITAL system resource address. Avanti DATALync card This card supports TAPI applications. It has only one mode of oper-...
Page 18
76-110-0175/G, Issue 2 2-6Figure 2-2 Connecting the module to the telephone Figure 2-3 Connecting a cable to the RJ45 port on the bottom of the telephone set 2.3.4Removing the telephone set stand These steps are only required when replacing an already attached stand with a module. 1.Place the telephone set face down. The stand of the set extends upward from the back of the tele- phone set. 2.Pull on the stand until it snaps out of place. 3.Replace it with the new module as described above (see...
Page 19
Section 2: INSTALLATION 2-7 2.3.5Connecting the cables to the option module Refer to Figure 2-3, 2-4, and 2-5. Figure 2-4 Option module cabling 1.To connect a data card to a telephone set with a DSS console, in addition to the above connection: •Remove the module’s small door C by snapping it out of place (see Figure 2-5). •Connect the RJ45 connector on one end of cable A to the left- hand RJ45 connector of the module, pass it under the bridge I, and place it in the horizontal cable slot (see Figure...
Page 20
76-110-0175/G, Issue 2 2-8Figure 2-5 Connecting the cables to the option module 2.3.6 Technical specifications for cabling the data modules Data card wiring connections The data card pin functions are shown in Table 2-3. Serial port parameters •19,200bits per second; •8 data bits; •no parity; •1 stop bit. Table 2-3: Data card wiring connections RJ 45 pinName 1GND 2TXD 3RXD 4CTS 5DCD 6DSR 7DTR 8RTSBto RJ45 connector on stationA to RJ45 connector on DSS console C H G D F E I