Page 41
34 Avanti Attendant console OVERFLOW When defined overflow conditions are met, the system automatically directs incoming calls to ring at a pro- grammed overflow extension. Calls continue to ring at the attendant position as well, and may be answered from either the overflow extension or the attendant position. Overflow conditions are met when: • More than a defined number of calls are waiting in the Main Call queue. • A call has been waiting in the Main Call queue beyond a defined time limit. •...
Page 42
Avanti Attendant console 35 SHUTTING DOWN THE CONSOLE To shut down the console •Press [POSITION BUSY] . The [POSITION BUSY] button indicator lights steadily. To return the console to operation • Press [POSITION BUSY] again. The [POSITION BUSY] button indicator light goes off. If your console has been programmed to require a password when deactivating position busy, you are prompted to enter your four-digit Executive Credit Code number. NOTE If all members of an attendant position activate position...
Page 43
36 Avanti Attendant console NIGHT SERVICE To put the console and the system into night service •Press [NIGHT] . The [NIGHT] indicator flashes. During Night service, the attendant console does not receive incoming calls and the queues are not active. To return the console to day service •Press [NIGHT] again. The [NIGHT] indicator goes off. Atc_txt.book Page 36 Wednesday, August 4, 1999 11:56 AM
Page 44
Avanti Attendant console 37 BUSY VERIFICATION You can verify the current state of any outside line. • Dial the number of an outside line. If the line is available, you seize the outside line and hear outside dial tone. Otherwise, busy tone is heard. The extension using the outside line and the outside line status (e.g. RING, BUSY, HOLD, etc.) is shown on the console display. Atc_txt.book Page 37 Wednesday, August 4, 1999 11:56 AM
Page 45
38 Avanti Attendant console CLEARING AN ALARM DISPLAY When a fault is detected in system operation, an alarm message is sent to the display of the attendant console. The System Administrator should be advised of any alarm indication. When the alarm message is no longer needed, you may clear the alarm from the display: •Press [CLEAR ALARM] . Atc_txt.book Page 38 Wednesday, August 4, 1999 11:56 AM
Page 46
Avanti Attendant console 39 CLASS OF SERVICE (COS) REASSIGNMENT You may change the Day and Night Class Of Service (COS) of any extension in the system. To change an extensions Class Of Service 1. Press . 2. Press {COS}. 3. Dial the extension number. 4. Press {DAY COS}. 5. Enter the new Day COS number. 6. Press {NIGHT COS}. 7. Enter the new Night COS number. 8. Do one of the following: •Press once to repeat the extension number entry procedure for another extension. or •Press three times,...
Page 47
40 Avanti Attendant console DSS UNIT The Attendant console may be equipped with a DSS (Direct Station Selection) unit to provide Direct Station Selection, Busy Lamp Field (BLF) indications and addi- tional personal speed dial buttons. The DSS unit has 30 programmable buttons and may be assigned up to four 30-button maps. A map is an arrange- ment of up to 30 entries representing extensions. This pro- vides the attendant with an additional 120 programmable buttons. To change the active map on the...
Page 48
Avanti Attendant console 41 DOOR UNIT If your system is equipped with a door unit and your con- sole has been programmed accordingly, you can control the entry of visitors into premises. When someone presses the doorbell, a call waiting ring sounds at your console. To speak to the visitor 1. Press [ANSWER] or the flashing [DOOR] button. 2. Speak to the visitor. To open the door •Press [ *] . To end your conversation • Press [RELEASE] or [DROP] . Atc_txt.book Page 41 Wednesday, August 4, 1999...
Page 49
42 Avanti Attendant console SETTING THE SYSTEM CLOCK If your console has been defined as the time setting set: 1. Press . 2. Press . 3. Dial the correct time, using “HHMM” in 24 hour format (e.g., 1530 for 3:30 pm). 4. Dial the correct date, using “DDMMYY” format (e.g. 030199 for March 1, 1999). 5. Press . Atc_txt.book Page 42 Wednesday, August 4, 1999 11:56 AM
Page 50
Avanti Attendant console 43 ALARM You may program the Attendant console to sound an alarm at any desired time. To set the alarm time 1. Press . 2. Press . The current programmed alarm time is displayed. Use the dialpad to enter the desired alarm time, using 24 hour format (e.g. 1530 for 3:30 pm). 3. Press . The alarm icon appears on the second line of the dis- play. NOTE Once an alarm has rung, the alarm setting is can- celed. To stop the alarm ring •Press [ANSWER] . To cancel the alarm setting...