    							Easy to Use Functions
    49
    Deinterlace
    This function allows you to determine the type of incoming video content-film, static interlaced video and 
    moving interlaced video. Different algorithms are applied for each of the content types.
    Select “Deinterlace” from the 
    “Options” menu on the menu screen.
    For operating the menu screen, see 
    page 31.
     Note
    •  In PAL50Hz or SECAM, the 2:2 pull down 
    enhancement will be enabled only in film 
    mode, after the film source has been 
    entered.
    Selected itemDescription
    DCTI
    This function is useful to 
    enhance video by replacing 
    the edges of the video with 
    edges that have steeper rise 
    and fall times. DCTI turns 
    sloped or sinusoidal 
    waveforms into rectangular 
    or square waveforms with 
    the same duty cycles and 
    peak-to-peak amplitude. Its 
    useful for 4:1:1 video 
    sources. The range is from 
    0 to 7.
    Video on film 
    (VOF)
    This function is used to 
    identify video artifacts while 
    in film mode. VOF attempts 
    to repair the artifacts using 
    the low-angle interpolator 
    while remaining in film 
    mode.
    Film Mode
    Reproduces the image of 
    the film source clearly. 
    Displays the optimized 
    image of film transformed 
    with 3:2 pull down (NTSC 
    and PAL60Hz)or 2:2 pull 
    down (PAL 50Hz and 
    SECAM) enhancement to 
    progressive mode images.
    Main Menu 
    						
    							50
    Easy to Use Functions
    Reset
    Select this option to set all items in the “Option” 
    menu to the factory default values.
    Lamp Timer Reset
    Lamp Timer Reset is used to reset the lamp 
    counter.
    You should reset the Timer after you install a 
    new lamp. The cumulative lamp usage time is 
    shown in the Status Screen.
    Main Menu
    Main Menu 
    						
    							Easy to Use Functions
    51
    Status Screen
    The Status screen displays information about the current input signal.
    Factory reset
    The Logo will be shown for about 20 seconds, 
    then the projector will be reset. 
     Note
    •  The Logo will be shown about 20 seconds, 
    and then the projector will be reset.
    Main Menu
    Screen display during Factory Reset
    Main Menu 
    						
    							Appendix
    53
    Appendix 
    						
    							54
    Appendix
    Maintenance
    Cleaning the projector
    „Unplug the power cord before cleaning the projector.
    „Avoid using benzene or thinner, as these can damage the finish on the cabinet and operation panel.
    „Do not use volatile agents such as insecticides on the projector.
    „Do not leave rubber or plastic objects in contact with the projector for long periods as they may damage 
    the finish of the projector.
    „Wipe off dirt gently with a soft flannel cloth.
    „For hard-to-remove dirt, soak a cloth in a neutral detergent diluted with water, wring the cloth well and then 
    wipe the projector.
    Strong cleaning detergents may discolor, warp or damage the coating on the projector. Make sure to test 
    on a small, inconspicuous area on the projector before using.
    Cleaning the lens
    „Use a commercially available blower or lens cleaning paper (for glasses and camera lenses) for cleaning 
    the lens. Do not use any liquid cleaning agents, as they may wear off the coating film on the surface of the 
    lens.
    „The surface of the lens is easily damaged, do not to scrape or hit the lens.
    Cleaning the exhaust and intake vents
    „Use a vacuum cleaner to clean dust from the exhaust vent and the intake vent.
    Neutral detergent 
    diluted with water
    N
    e
    ut
    ral
     d
    e
    te
    rge
    nt
    Cleaning 
    Paper 
    						
    							Appendix
    55
    Cleaning the Ventilative Holes
    •  This projector is equipped with ventilative 
    holes to ensure the optimal operating 
    condition of the projector.
    •  Periodically clean the ventilative hole by 
    vacuuming it off with a vacuum cleaner.
    •  The ventilative holes should be cleaned 
    every 100 hours of use. Clean the 
    ventilative holes more often when the 
    projector is used in a dirty or smoky 
    location.
    Cleaning the 
    Ventilative Holes
    1Turn off the power and 
    disconnect the power cord.
    Press  on the projector or  on 
    the remote control to turn off the power. 
    Wait until the cooling fan stops.
    2Unplug the Power Cord.
    3Clean the dust off by placing the 
    cleaner hose on the intake and 
    exhaust ventilative holes.
    STATUSEXIT
    INPUTMENU
    ECO
    ENTER
    COMPONENT 1
    COMPONENT 2
    Side and Rear view
    Ventilative holes
    Bottom view
    Ventilative holes
    Power button
    mp chassis cover while replacing the lamp.xt to them until they have sufficiently cooled down.
    nvironment.Made in Taiwan
    Pr/Cr Pb/CbYPCDVI 
    						
    							56
    Appendix
    About the Lamp
    The projector lamp has a life of 2000 hours. Maintain proper ventilation to keep the lamp operating 
    throughout its lifetime. Do not subject the projector to unnecessary vibration to ensure that the 
    lamp does not break.
    „It is recommended that the lamp (sold separately) be replaced after approximately 2,000 cumulative hours 
    of use or when you notice a significant deterioration in the picture and color quality. The number of hours 
    the lamp has been used can be checked with “Lamp Timer” in the “Options” menu on the menu screen.
    „For lamp replacement, please consult your nearest Authorized Service Center or Dealer.
    „The actual lamp service life may be less than 2000 hours depending on the environment in which the 
    projector is used.
    Caution Concer ning the Lamp
    „This projector uses a pressurized mercury lamp. A loud sound may indicate lamp failure. Lamp failure is 
    caused by excessive shock, improper cooling, surface scratches or deterioration of the lamp due to usage. 
    The period of time up to failure largely varies depending on the individual lamp and/or the condition and 
    the frequency of use. It is important to note that failure can often result in the bulb cracking.
    „When the lamp replacement indicator and on-screen display icon are illuminated or are flashing, it is 
    recommended that the lamp be replaced with a new one immediately, even if the lamp appears to be 
    operating normally.
    „If the lamp breaks glass particles may spread inside the lamp cage or gas contained in the lamp may be 
    vented into the room from the exhaust vent. As the gas in this lamp contains mercury, ventilate the room 
    well if the lamp breaks and avoid all exposure to the released gas. In case of exposure to the gas, consult 
    with a doctor as soon as possible.
    „If the lamp breaks, there is also a possibility that glass particles may spread inside the projector.
    If this happens, it is recommended you contact your nearest Authorized Dealer to remove the damaged 
    lamp and assure safe operation.
    Replacing the Lamp
    CAUTION!  Do not remove the lamp unit immediately after operation of the projector. The 
    lamp will be hot and touching it can lead to burn or injury. Wait at least one hour after the 
    power cord is disconnected to allow the surface of the lamp unit to fully cool before removing 
    the lamp unit. 
    						
    							Appendix
    57
    Removing and Installing the Lamp Unit
    Follow these instructions to replace the lamp.
    •  Be sure to remove the lamp unit by the handle. Be sure not to touch the glass surface of the lamp unit or 
    the inside of the projector.
    •  To avoid injuring yourself and damage to the lamp, be sure to carefully follow the steps below.
    •  Do not loosen other screws except for the lamp unit cover and lamp unit. 
    (Only the silver screws are loosened).
    1. If the projector is running, press  on the projector or  on the remote control to 
    turn off the power. Wait until the cooling fan stops.
     Warning!
    Do not remove the lamp unit from the projector right after use. The lamp will be very hot and may cause burn 
    or injury.
    2. Disconnect the power cord and wait at least an hour for the lamp to cool.
    3. Remove the lamp unit cover.
    •  Loosen the user service screw that secures the lamp unit cover. Then open the cover in the direction of the 
    arrow.
    COMPONENT 1
    COMPONENT 2
    STATUSEXIT
    INPUTMENU
    ECO
    ENTER
     M4* 8.9 screws 
    						
    							58
    Appendix
    4. Remove the lamp unit.
    •  Loosen the securing screws from the lamp unit. Hold the lamp unit by the handle and pull it in the direction 
    of the arrow.
       
    5. Insert the new lamp unit.
    •  Press the lamp unit firmly into the lamp unit compartment. Fasten the securing screws.
    •  Attach the lamp unit cover.
    •  Close the lamp unit cover in the direction of the arrow (to the close mark) on the side of the projector. Then 
    tighten the user service screw.
     Info
    •  If the lamp unit and lamp cover are not correctly installed, the power will not turn on, even if the power cord 
    is connected to the projector.
    Resetting the Lamp Timer
    Reset the lamp timer after replacing the lamp.
    1. Connect the power cord.
    •  Plug the power cord into the AC socket of the 
    projector.
    2. Reset the lamp timer.
    •  While holding down ,  and  on the projector, 
    press  on the projector. (See page 50)
    •  “LAMP 0H” is displayed, indicating that the lamp timer 
    is reset.
     Info
    Make sure to reset the lamp timer only when replacing 
    the lamp. If you reset the lamp timer and continue to 
    use the same lamp, this may cause the lamp to become 
    damaged or explode.
    mp chassis cover while replacing the lamp.xt to them until they have sufficiently cooled down.
    nvironment.Made in Taiwan
    Pr/Cr Pb/CbYPCDVI
    STATUSEXIT
    INPUTMENU
    ECO
    ENTER
    ENTER
    ENTER 
    						
    All Studio Experience manuals Comments (0)

    Related Manuals for Studio Experience Projector Premier 30hd User Manual