    System Specifications
    This chapter describes the hardware used by theXTSsystem and lists the specifications
    for each component. 
    						
    							» » » » » » »  NOTES   » » » » » » » 
    						
    							System Capacities2-3
    Chapter 2 - System Specifications
    System Capacities
    The following tables and charts describe system capacities and display the configuration
    flexibility of the system.
    The KSU contains a PSU slot, nine universal slots, one MPB slot, one LMU slot, one RAU slot, and
    PFTU and RGU connectors.
    Table 2-1: System Capacity
    DescriptionUniversal
    SlotsUsable Capacity
    MPB2 MPB1
    Time Slots*Cabinet 0 9 136 Time Slots 136 Time Slots
    Cabinet 1 9 96-144 Time Slots** N/A
    Cabinet 2 9 96-144 Time Slots** N/A
    KSU Cabinets 3 Cabinets 1 Cabinet
    Serial Ports (RS-232C) 4 Ports
    (MPB: 2, MISB: 2)3Ports
    (MPB:1, MISB:2)
    Alarm 3 Inputs
    (RAU: 2, MISB: 1)3 Inputs
    (RAU: 2, MISB: 1)
    External Control Contacts 7 Contacts
    (RAU: 3, MISB: 4)7Contacts
    (RAU: 3, MISB: 4)
    Music Source Inputs 3 Inputs
    (MPB: 1, MISB: 2)2Inputs
    (MPB: 0, MISB: 2)
    DTMF Receivers 24 Receivers
    (MPB:4,SLT/COcards:20)24 Receivers
    (MPB:0,SLT/COcards:24)
    Power Fail Circuits 30 Circuits 30 Circuits
    Paging ZonesExternal 3 Zones
    (MPB: 1, MISB: 2)2 Zones
    (MPB: 0, MISB: 2)
    Internal 8 Zones 8 Zones
    DSS/BLF Consoles 3 Consoles (per station) 3 Consoles (per station)
    Ethernet Connection 1 N/A
    * Time slots are used to support each CO Line and each station. A Cabinet cannot support more than 96 stations.
    ** Maximum time slots on Cabinet 1 and Cabinet 2 can range from 96 to 144 each, but the total time slots between the
    two Cabinets cannot exceed 240.
    *** MPB1 - Maximum COs are 48 and maximum stations are 96
    MPB2 - Maximum COs are 144 and maximum stations are 252 
    						
    							2-4System Components
    Chapter 2 - System Specifications
    System Components
    This table shows the slot positions for each card that can be installed in theXTSSystem.
    Table 2-2: System Card Description
    Part
    NumberBoardNumber of
    Time SlotsSlot
    PositionDescription
    8031-41 BRIB 8 1-7 or 0-7 Basic Rate Interface Board
    8031-10 DIDB 4 1-8 or 0-8 Direct Inward Dial Board
    8032-30 DTIB12 12 0-8 Digital Telephone Interface Board
    8032-40 DTIB24 24 0-8 Digital Terlephone Interface Board
    8031-50 DTRU --- LCOB, SLIB, DIDB DTMF Receiver Unit (2 port)
    3031-60 DTRU4 --- LCOBE, LCOBC,
    SLIBE, SLIBC,
    T1IB, PRIB, BRIBDTMF Receiver Unit (4 port)
    8032-20 ETIB 12 1-8 or 0-8 Electronic Telephone Interface Board
    3000-00 KSU --- --- Key Service Unit
    8031-00 LCOB 6 1-8 or 0-8 Loop Start CO Interface Board
    3031-02 LCOBE 8 1-8 or 0-8 Loop Start CO Interface Board (01, 3Q)
    3031-03 LCOBC 8 1-7 or 0-7 Loop Start CO Interface (01, 3Q) with Caller ID
    3035-01 LMU1 --- LMU Link Module Unit (Cabinet 0 only)
    3035-02 LMU2 --- LMU Link Module Unit (Cabinets 1 & 2 only)
    8035-00 MISB --- 8 only Miscellaneous Board (Cabinet 0 only)
    3030-30 MODU --- MPB 19.2 Kbps Internal Modem
    3030-01 MPB1 --- MPB Main Processing Board = 136 Time Slots Usable
    3030-03 MPB2 --- MPB Main Processing Board = 376 Time Slots Usable
    8033-10 MSGU --- SLIB Message Waiting Unit
    3033-10 MSGU48 --- SLIBE, SLIBC Message Waiting Unit
    8036-00 PFTU --- --- Power Failure Transfer Unit
    The first range, for entries that show two ranges of slot positions, applies to Cabinet 0. For example, the LCOBC card can be
    used in slot 1-7 of Cabinet 0 and in slots 0-7 in either Cabinet 1 or Cabinet 2. 
    						
    							System Components2-5
    Chapter 2 - System Specifications
    Part Num-
    berBoardNumber of
    Time SlotsSlot
    PositionDescription
    3030-10 PMU --- MPB1 Program Module Unit, 4 MB ROM
    3030-20 PMU --- MPB2 Program Module Unit, 8 MB ROM
    8031-40 PRIB 24 1-7 or 0-7 Primary Rate Interface Board
    3071-10 PSU --- PSU Power Supply Unit, 350W
    3035-03 RAU --- RAU Relay Alarm Unit (used only in Cabinet 0)
    3073-00 RGU3 --- --- Ring Generator Unit (25Hz) : Sine Wave, Internal
    8035-10 SIU --- MISB Serial Interface Unit
    8033-00 SLIB 6 1-8 or 0-8 Single Line Interface Board
    3033-03 SLIBC 12 1-7 or 0-7 Single Line Interface Board with Caller ID
    3033-02 SLIBE 12 1-8 or 0-8 Single Line Interface Board
    8031-31 T1IB 24 1-7 or 0-7 T1 Interface Board
    TR8037-02 VOIP 8 1-7 or 0-7
    DiscoveryVoIP Card w/one VoIP Module
    TR8037-04 VOIP 8 1-7 or 0-7
    DiscoveryVoIP Card w/two VoIP Modules
    TR8037-06 VOIP 8 1-7 or 0-7
    DiscoveryVoIP Card w/three VoIP Modules
    TR8037-08 VOIP 8 1-7 or 0-7
    DiscoveryVoIP Card w/four VoIP Modules
    TR8037-10 Module 2 VOIP
    DiscoveryVoIP module only (for upgrade)
    The first range, for entries that show two ranges of slot positions, applies to Cabinet 0. For example, the T1IB card can be
    used in slot 1-7 of Cabinet 0 and in slots 0-7 in either Cabinet 1 or Cabinet 2.
    Table 2-2: System Card Description 
    						
    							2-6System Configuration Tables
    Chapter 2 - System Specifications
    System Configuration Tables
    Table 2-3: System Capacity
    ItemCapacity
    Account Codes
    Number of digits per account code
    Number of Account Codes- Unverified
    Number of Account Codes - VerifiedUp to 12 unverified digits
    Unlimited
    250 Account Codes
    ACD Groups
    Groups
    Members
    RAN Announcements
    Calls in QueueSoftwaresupportsupto16Groups
    Software supports up to 252 stations in each Group
    Eight RAN Announcements per system, 3 per ACD Group
    All CO Lines may be queued for an ACD Group
    Attendants Up to 3 stations can be designated as Attendants.
    CO Lines
    CO/PBX/Centrex Lines
    DID Lines
    T-1 Trunks
    ISDN TrunksMPB1
    48 maximumMPB2
    144 maximum
    Conference
    Circuits
    Par ties10 Conferences per system
    8 parties per conference, of which 5 can be external
    Dialing Memory
    Station Speed Dialing
    System Speed Dialing
    Total Speed Dial20 Bins per station (24-digits)
    980 Bins per system (24-digits)
    3000 Bins per system (24-digits)
    Digital DSS/BLF Units 180 maximum
    Each DSS/BLF unit requires 1 station port and reduces station capacity by 1.
    DSS/BLF maps may not be duplicated at one station.
    1 station may have up to 3 DSS/BLF units associated with it.
    DISA Circuits Unlimited number of CO lines may be programmed simultaneously.
    Hunt Groups
    Groups
    Members
    TypesSoftwaresupportsupto8Groups
    Softwaresupportsupto8stationsineachGroup
    Station, Pilot Hunting, or Pilot Ring All
    Loop Supervision Disconnect 700 msec. duration (CO or Internal call to SLT )
    Music Channels
    Music-On-Hold/Background Music 8 Channels per system (4-8 on CO, ports 1 & 2 on MISB, port 3 on MPB2) (port 3 is
    unavailable for MPB1)
    Page Zones
    Internal Paging
    External PagingMPB1
    8 maximum (software controlled)
    2 maximumMPB2
    8 maximum (software controlled)
    3 maximum 
    						
    							System Configuration Tables2-7
    Chapter 2 - System Specifications
    Stations
    Analog Stations
    Digital Telephones
    Single Line TelephonesMPB1
    96 maximumMPB2
    252 maximum
    No more than 96 stations are
    supported per Cabinet.
    UCD Groups
    Groups
    Members
    RAN Announcements
    Calls In QueueSoftwaresupportsupto8Groups
    Softwaresupportsupto8stationsineachGroup
    Eight RAN Announcements per system, 2 per UCD Group
    All CO Lines may be queued for a UCD Group
    Voice Mail Groups
    Groups
    Members (ports)
    Integration Method
    Positive Disconnect
    VM Message Wait
    VM Disconnect SignalSoftwaresupportsupto8Groups
    Software supports up to 24 stations per group
    In-Band signaling (DTMF)
    Loop supervision is provided to ensure disconnect
    Programmable 12-digit (DTMF) string
    If 0 digits are programmed, 15 sec of silence are followed by a busy tone.
    Table 2-4: Environment Specification
    Item Degrees (ºF) Degrees (ºC)
    Operation Temperature 32-104 0-40
    Optimum Operation Temperature 68-78 20-26
    Storage Temperature 32-158 10-70
    Relative Humidity 0-80% non-condensing
    Table 2-5: Loop Limits
    Item
    Capacity
    Analog Electronic Telephone* Maximum length of station loop:
    1000 feet of 24 AWG
    (4 wire, inside wiring, twisted cable)
    Digital Telephones* Maximum length of station loop:
    1000 feet of 24 AWG
    (2-wire, inside wiring, twisted cable)
    Single Line Telephones* 2000 feet of 24 AWG
    *All stations must be installed in the same building. Station circuitry does not contain protection to support off-
    premise operation.
    Table 2-6: FCC Registration Numbers
    System
    FCC Number
    For aKey Systemconfiguration (button appearance) KF: 5JYKOR-45505-MF-E
    For aHybrid Systemconfiguration (dial access codes) MF: 5JYKOR-45505-MF-E
    Table 2-3: System Capacity 
    						
    							2-8System Configuration Tables
    Chapter 2 - System Specifications
    Table 2-7: Electrical Specifications
    Item
    Specification
    Power Supply
    AC Voltage Input
    AC Power
    AC Input Fuse
    DC Output Voltage120 or 220 +/- 10% Volt AC @48-63Hz
    350W
    5.0 amp @ 220Volt AC
    + 5V @ 10A, - 5V @ 1.5A, + 30V @ 8.4A
    Battery Backup
    Input Voltage
    Battery Fuse
    Charging Current24Volt DC
    12.5amp @250Volt AC
    Maximum 1A
    External Relay Contact 1 amp @24Volt DC
    Longitudinal Balance 60 db from 200 Hz to 1,000 Hz
    40 db from 1000 Hz to 4000 Hz
    Idle Channel Noise Less than 15 dbrnco for all connections
    Cross Talk Attenuation Greater than 75 dbm Station to CO and Station to Station
    Single Frequency Distortion
    (300 - 3400 Hz)Station to CO Line and station to station:
    Better than 2.0% or 34 db for an
    Output level -30 dbm to 0 dbm
    Ringing Detect Sensitivity 40Vrms @16-30Hz
    30Vrms @30-37Hz
    Ringer Equivalence Number (REN) LCOB: 0.8B; DIDB: 0.0B; T1IB: 6.0P
    Co Line Signaling - DTMF Frequency pair at ±5dbm
    Frequency tolerance ±1.5%
    CO Line Signaling - Dial Pulse 10 pps and 20 pps programmable
    Input Level Range +10 db maximum
    Music Source
    Music-On-Hold input
    Background Music input600Ω input atØdbm maximum from music source
    600Ω input atØdbm maximum from music source
    External Page Port
    Output Impedance
    Output Power w/o Compression600Ω @ 0dbm
    5 milliwatt max
    CSA File Number (NRTL/C) LR57228
    Telephone Transmitter Electret mic compatible 
    						
    							System Configuration Tables2-9
    Chapter 2 - System Specifications
    Table 2-8: Dialing Specifications
    Item
    Specification
    DTMF Dialing
    Frequency Deviation
    Rise Time
    Duration of DTMF Signal
    Interdigit TimeLess than +/-1%
    Maximum 3ms
    Minimum 75ms
    Minimum 75ms
    Pulse Dialing
    Pulse Dialing Rate
    Pulse Break/Make Duration10 or 20 pps
    60/40% or 67/33%
    CO Type Loop Start, 600 ohm, current sensing
    Table 2-9: Trunk Ordering Info: Public Network/Private Lease Lines
    System Port Identification, Facility Interface and Service Order Codes
    Interface Card Ringer Equivalent Number (REN) Facility Line Interface Jack Type
    CO Port (LCOB) 0.8B 02LS2 RJ11
    CO Port (LCOBE/LCOBC) 0.8B 02LS2 RJ21X
    Direct Inward Dial (DIDB) 0.0B 02RV2-T RJ11
    T-1 Port ( T1IB) or
    ISDN Port (PRIB)6.0P 04DU9-B RJ45
    Table 2-10: Dimension and Weight
    ItemHeight Width Depth Weight
    in mm in mm in mm lbs kg
    KSU 16.2 411 24.8 630 9.4 238 25.3 11.5
    Digital Keyset 9.3 236 7.6 192 3.3 84 3.3 1.5
    Digital DSS/BLF Console 9.3 236 4.9 125 2.4 62 2.0 0.9 
    						
    							2-10System Configuration Tables
    Chapter 2 - System Specifications
    Table 2-11: Electronic Telephone Audible Signals
    Type of Signal FrequencySignal Duration
    (in seconds unless otherwise indicated)
    Electronic Telephone Signals
    Incoming CO Line 440+480 0.4 on/0.4 off/0.4 on/2.0 off; Repeated
    Intercom Tone Ringing 440+480 0.8 on/2.4 off; Repeated
    Intercom Call Announce (H-P modes) 440 0.2 on/0.2 off; (3 bursts)
    Transferred CO Line 440+480 0.8 on/2.4 off; Repeated
    CO Line Recall 440+480 0.24 on/0.6 off; Repeated
    Message Wait Call Back 440+480 0.8 on/2.4 off; Repeated
    CO Queue Call Back 440+480 0.8 on/2.4 off; Repeated
    Camp-On 440 0.8on(1burst)
    Paging Alert Tone 440 1.0 on
    Type of Signal FrequencySignal Duration
    (in seconds unless otherwise indicated)
    Electronic Telephone Confidence Tones
    Intercom Ringback 440+480 0.8 on/2.4 off
    Transferred CO Line 440+480 0.8 on/2.4 off
    Call Announce 440 0.2 on/0.2 off; (3 bursts)
    Busy Tone 480+620 1.0 on/0.2 off/1.0 on/0.2 off/0.2 on/ 0.2 off/
    0.2on/0.2 off/0.2 on; Repeated
    Error Tone 480+620 0.2 on/0.1 off; Repeated
    Intercom Dial Tone 350+440 Steady
    DND Tone 350+440 0.4 on/0.4 off/0.2 on/0.2 off/0.2 on; Repeated
    Paging Confirmation Tone 350+440 1.0 on
    Conference Time-out/Re-Enter Tone 440 Programmable Steady Tone
    Confirmation Tone 350+440 0.2 on/0.2 off; (3 bursts) CO/PBX 
    						