2 System Specifications This chapter describes the hardware used by theXTSsystem and lists the specifications for each component.
System Capacities2-3 Chapter 2 - System Specifications System Capacities The following tables and charts describe system capacities and display the configuration flexibility of the system. The KSU contains a PSU slot, nine universal slots, one MPB slot, one LMU slot, one RAU slot, and PFTU and RGU connectors. Table 2-1: System Capacity DescriptionUniversal SlotsUsable Capacity MPB2 MPB1 Time Slots*Cabinet 0 9 136 Time Slots 136 Time Slots Cabinet 1 9 96-144 Time Slots** N/A Cabinet 2 9 96-144 Time Slots** N/A KSU Cabinets 3 Cabinets 1 Cabinet Serial Ports (RS-232C) 4 Ports (MPB: 2, MISB: 2)3Ports (MPB:1, MISB:2) Alarm 3 Inputs (RAU: 2, MISB: 1)3 Inputs (RAU: 2, MISB: 1) External Control Contacts 7 Contacts (RAU: 3, MISB: 4)7Contacts (RAU: 3, MISB: 4) Music Source Inputs 3 Inputs (MPB: 1, MISB: 2)2Inputs (MPB: 0, MISB: 2) DTMF Receivers 24 Receivers (MPB:4,SLT/COcards:20)24 Receivers (MPB:0,SLT/COcards:24) Power Fail Circuits 30 Circuits 30 Circuits Paging ZonesExternal 3 Zones (MPB: 1, MISB: 2)2 Zones (MPB: 0, MISB: 2) Internal 8 Zones 8 Zones DSS/BLF Consoles 3 Consoles (per station) 3 Consoles (per station) Ethernet Connection 1 N/A * Time slots are used to support each CO Line and each station. A Cabinet cannot support more than 96 stations. ** Maximum time slots on Cabinet 1 and Cabinet 2 can range from 96 to 144 each, but the total time slots between the two Cabinets cannot exceed 240. *** MPB1 - Maximum COs are 48 and maximum stations are 96 MPB2 - Maximum COs are 144 and maximum stations are 252
2-4System Components Chapter 2 - System Specifications System Components This table shows the slot positions for each card that can be installed in theXTSSystem. Table 2-2: System Card Description Part NumberBoardNumber of Time SlotsSlot PositionDescription 8031-41 BRIB 8 1-7 or 0-7 Basic Rate Interface Board 8031-10 DIDB 4 1-8 or 0-8 Direct Inward Dial Board 8032-30 DTIB12 12 0-8 Digital Telephone Interface Board 8032-40 DTIB24 24 0-8 Digital Terlephone Interface Board 8031-50 DTRU --- LCOB, SLIB, DIDB DTMF Receiver Unit (2 port) 3031-60 DTRU4 --- LCOBE, LCOBC, SLIBE, SLIBC, T1IB, PRIB, BRIBDTMF Receiver Unit (4 port) 8032-20 ETIB 12 1-8 or 0-8 Electronic Telephone Interface Board 3000-00 KSU --- --- Key Service Unit 8031-00 LCOB 6 1-8 or 0-8 Loop Start CO Interface Board 3031-02 LCOBE 8 1-8 or 0-8 Loop Start CO Interface Board (01, 3Q) 3031-03 LCOBC 8 1-7 or 0-7 Loop Start CO Interface (01, 3Q) with Caller ID 3035-01 LMU1 --- LMU Link Module Unit (Cabinet 0 only) 3035-02 LMU2 --- LMU Link Module Unit (Cabinets 1 & 2 only) 8035-00 MISB --- 8 only Miscellaneous Board (Cabinet 0 only) 3030-30 MODU --- MPB 19.2 Kbps Internal Modem 3030-01 MPB1 --- MPB Main Processing Board = 136 Time Slots Usable 3030-03 MPB2 --- MPB Main Processing Board = 376 Time Slots Usable 8033-10 MSGU --- SLIB Message Waiting Unit 3033-10 MSGU48 --- SLIBE, SLIBC Message Waiting Unit 8036-00 PFTU --- --- Power Failure Transfer Unit The first range, for entries that show two ranges of slot positions, applies to Cabinet 0. For example, the LCOBC card can be used in slot 1-7 of Cabinet 0 and in slots 0-7 in either Cabinet 1 or Cabinet 2.
System Components2-5 Chapter 2 - System Specifications Part Num- berBoardNumber of Time SlotsSlot PositionDescription 3030-10 PMU --- MPB1 Program Module Unit, 4 MB ROM 3030-20 PMU --- MPB2 Program Module Unit, 8 MB ROM 8031-40 PRIB 24 1-7 or 0-7 Primary Rate Interface Board 3071-10 PSU --- PSU Power Supply Unit, 350W 3035-03 RAU --- RAU Relay Alarm Unit (used only in Cabinet 0) 3073-00 RGU3 --- --- Ring Generator Unit (25Hz) : Sine Wave, Internal 8035-10 SIU --- MISB Serial Interface Unit 8033-00 SLIB 6 1-8 or 0-8 Single Line Interface Board 3033-03 SLIBC 12 1-7 or 0-7 Single Line Interface Board with Caller ID 3033-02 SLIBE 12 1-8 or 0-8 Single Line Interface Board 8031-31 T1IB 24 1-7 or 0-7 T1 Interface Board TR8037-02 VOIP 8 1-7 or 0-7 DiscoveryVoIP Card w/one VoIP Module TR8037-04 VOIP 8 1-7 or 0-7 DiscoveryVoIP Card w/two VoIP Modules TR8037-06 VOIP 8 1-7 or 0-7 DiscoveryVoIP Card w/three VoIP Modules TR8037-08 VOIP 8 1-7 or 0-7 DiscoveryVoIP Card w/four VoIP Modules TR8037-10 Module 2 VOIP DiscoveryVoIP module only (for upgrade) The first range, for entries that show two ranges of slot positions, applies to Cabinet 0. For example, the T1IB card can be used in slot 1-7 of Cabinet 0 and in slots 0-7 in either Cabinet 1 or Cabinet 2. Table 2-2: System Card Description
2-6System Configuration Tables Chapter 2 - System Specifications System Configuration Tables Table 2-3: System Capacity ItemCapacity Account Codes Number of digits per account code Number of Account Codes- Unverified Number of Account Codes - VerifiedUp to 12 unverified digits Unlimited 250 Account Codes ACD Groups Groups Members RAN Announcements Calls in QueueSoftwaresupportsupto16Groups Software supports up to 252 stations in each Group Eight RAN Announcements per system, 3 per ACD Group All CO Lines may be queued for an ACD Group Attendants Up to 3 stations can be designated as Attendants. CO Lines CO/PBX/Centrex Lines DID Lines T-1 Trunks ISDN TrunksMPB1 48 maximumMPB2 144 maximum Conference Circuits Par ties10 Conferences per system 8 parties per conference, of which 5 can be external Dialing Memory Station Speed Dialing System Speed Dialing Total Speed Dial20 Bins per station (24-digits) 980 Bins per system (24-digits) 3000 Bins per system (24-digits) Digital DSS/BLF Units 180 maximum Each DSS/BLF unit requires 1 station port and reduces station capacity by 1. DSS/BLF maps may not be duplicated at one station. 1 station may have up to 3 DSS/BLF units associated with it. DISA Circuits Unlimited number of CO lines may be programmed simultaneously. Hunt Groups Groups Members TypesSoftwaresupportsupto8Groups Softwaresupportsupto8stationsineachGroup Station, Pilot Hunting, or Pilot Ring All Loop Supervision Disconnect 700 msec. duration (CO or Internal call to SLT ) Music Channels Music-On-Hold/Background Music 8 Channels per system (4-8 on CO, ports 1 & 2 on MISB, port 3 on MPB2) (port 3 is unavailable for MPB1) Page Zones Internal Paging External PagingMPB1 8 maximum (software controlled) 2 maximumMPB2 8 maximum (software controlled) 3 maximum
System Configuration Tables2-7 Chapter 2 - System Specifications Stations Analog Stations Digital Telephones Single Line TelephonesMPB1 96 maximumMPB2 252 maximum No more than 96 stations are supported per Cabinet. UCD Groups Groups Members RAN Announcements Calls In QueueSoftwaresupportsupto8Groups Softwaresupportsupto8stationsineachGroup Eight RAN Announcements per system, 2 per UCD Group All CO Lines may be queued for a UCD Group Voice Mail Groups Groups Members (ports) Integration Method Positive Disconnect VM Message Wait VM Disconnect SignalSoftwaresupportsupto8Groups Software supports up to 24 stations per group In-Band signaling (DTMF) Loop supervision is provided to ensure disconnect Programmable 12-digit (DTMF) string If 0 digits are programmed, 15 sec of silence are followed by a busy tone. Table 2-4: Environment Specification Item Degrees (ºF) Degrees (ºC) Operation Temperature 32-104 0-40 Optimum Operation Temperature 68-78 20-26 Storage Temperature 32-158 10-70 Relative Humidity 0-80% non-condensing Table 2-5: Loop Limits Item Capacity Analog Electronic Telephone* Maximum length of station loop: 1000 feet of 24 AWG (4 wire, inside wiring, twisted cable) Digital Telephones* Maximum length of station loop: 1000 feet of 24 AWG (2-wire, inside wiring, twisted cable) Single Line Telephones* 2000 feet of 24 AWG *All stations must be installed in the same building. Station circuitry does not contain protection to support off- premise operation. Table 2-6: FCC Registration Numbers System FCC Number For aKey Systemconfiguration (button appearance) KF: 5JYKOR-45505-MF-E For aHybrid Systemconfiguration (dial access codes) MF: 5JYKOR-45505-MF-E Table 2-3: System Capacity
2-8System Configuration Tables Chapter 2 - System Specifications Table 2-7: Electrical Specifications Item Specification Power Supply AC Voltage Input AC Power AC Input Fuse DC Output Voltage120 or 220 +/- 10% Volt AC @48-63Hz 350W 5.0 amp @ 220Volt AC + 5V @ 10A, - 5V @ 1.5A, + 30V @ 8.4A Battery Backup Input Voltage Battery Fuse Charging Current24Volt DC 12.5amp @250Volt AC Maximum 1A External Relay Contact 1 amp @24Volt DC Longitudinal Balance 60 db from 200 Hz to 1,000 Hz 40 db from 1000 Hz to 4000 Hz Idle Channel Noise Less than 15 dbrnco for all connections Cross Talk Attenuation Greater than 75 dbm Station to CO and Station to Station Single Frequency Distortion (300 - 3400 Hz)Station to CO Line and station to station: Better than 2.0% or 34 db for an Output level -30 dbm to 0 dbm Ringing Detect Sensitivity 40Vrms @16-30Hz 30Vrms @30-37Hz Ringer Equivalence Number (REN) LCOB: 0.8B; DIDB: 0.0B; T1IB: 6.0P Co Line Signaling - DTMF Frequency pair at ±5dbm Frequency tolerance ±1.5% CO Line Signaling - Dial Pulse 10 pps and 20 pps programmable Input Level Range +10 db maximum Music Source Music-On-Hold input Background Music input600Ω input atØdbm maximum from music source 600Ω input atØdbm maximum from music source External Page Port Output Impedance Output Power w/o Compression600Ω @ 0dbm 5 milliwatt max CSA File Number (NRTL/C) LR57228 Telephone Transmitter Electret mic compatible
System Configuration Tables2-9 Chapter 2 - System Specifications Table 2-8: Dialing Specifications Item Specification DTMF Dialing Frequency Deviation Rise Time Duration of DTMF Signal Interdigit TimeLess than +/-1% Maximum 3ms Minimum 75ms Minimum 75ms Pulse Dialing Pulse Dialing Rate Pulse Break/Make Duration10 or 20 pps 60/40% or 67/33% CO Type Loop Start, 600 ohm, current sensing Table 2-9: Trunk Ordering Info: Public Network/Private Lease Lines System Port Identification, Facility Interface and Service Order Codes Interface Card Ringer Equivalent Number (REN) Facility Line Interface Jack Type CO Port (LCOB) 0.8B 02LS2 RJ11 CO Port (LCOBE/LCOBC) 0.8B 02LS2 RJ21X Direct Inward Dial (DIDB) 0.0B 02RV2-T RJ11 T-1 Port ( T1IB) or ISDN Port (PRIB)6.0P 04DU9-B RJ45 Table 2-10: Dimension and Weight ItemHeight Width Depth Weight in mm in mm in mm lbs kg KSU 16.2 411 24.8 630 9.4 238 25.3 11.5 Digital Keyset 9.3 236 7.6 192 3.3 84 3.3 1.5 Digital DSS/BLF Console 9.3 236 4.9 125 2.4 62 2.0 0.9
2-10System Configuration Tables Chapter 2 - System Specifications Table 2-11: Electronic Telephone Audible Signals Type of Signal FrequencySignal Duration (in seconds unless otherwise indicated) Electronic Telephone Signals Incoming CO Line 440+480 0.4 on/0.4 off/0.4 on/2.0 off; Repeated Intercom Tone Ringing 440+480 0.8 on/2.4 off; Repeated Intercom Call Announce (H-P modes) 440 0.2 on/0.2 off; (3 bursts) Transferred CO Line 440+480 0.8 on/2.4 off; Repeated CO Line Recall 440+480 0.24 on/0.6 off; Repeated Message Wait Call Back 440+480 0.8 on/2.4 off; Repeated CO Queue Call Back 440+480 0.8 on/2.4 off; Repeated Camp-On 440 0.8on(1burst) Paging Alert Tone 440 1.0 on Type of Signal FrequencySignal Duration (in seconds unless otherwise indicated) Electronic Telephone Confidence Tones Intercom Ringback 440+480 0.8 on/2.4 off Transferred CO Line 440+480 0.8 on/2.4 off Call Announce 440 0.2 on/0.2 off; (3 bursts) Busy Tone 480+620 1.0 on/0.2 off/1.0 on/0.2 off/0.2 on/ 0.2 off/ 0.2on/0.2 off/0.2 on; Repeated Error Tone 480+620 0.2 on/0.1 off; Repeated Intercom Dial Tone 350+440 Steady DND Tone 350+440 0.4 on/0.4 off/0.2 on/0.2 off/0.2 on; Repeated Paging Confirmation Tone 350+440 1.0 on Conference Time-out/Re-Enter Tone 440 Programmable Steady Tone Confirmation Tone 350+440 0.2 on/0.2 off; (3 bursts) CO/PBX