51 Advanced Recording Operations If you have selected in step 3When you set the white balance to one-push white balance mode, the setting is locked and maintained even if lighting conditions change. You can achieve recording with natural colors without the image being affected by ambient light. (With the indicator on the screen) (1)Shoot a white object such as paper fully. (2)Press the SEL/PUSH EXEC dial. The indicator flashes quickly. When the white balance has been adjusted and stored in the memory, the indicator stops flashing. The setting will be maintained even if the battery is detached. To return to automatic adjustmentSet the AUTO LOCK selector to AUTO LOCK or press WHT BAL. The white balance indicator disappears from the LCD or viewfinder screen. Notes on white balance •When you shoot with studio lighting or video lighting, use the n (indoor) mode. •When you shoot with fluorescent lighting, readjust the white balance using the (one-push white balance) mode , or use the automatic white balance mode. If you use the n (indoor) mode, white balance may not be adjusted appropriately. Shooting when lighting conditions have changed •When lighting conditions have changed, readjust the white balance while the camcorder is in standby mode. •In automatic white balance mode, point your camcorder at a white subject for about 10 seconds after setting the POWER switch to CAMERA to get a better adjustment when: –You detach the battery for replacement. –You bring your camcorder outdoors from the interior of a house, or vice versa. If the indicator does not stop flashing after you press the SEL/PUSH EXEC dial The white balance cannot be set. Use the automatic white balance mode. Adjusting the white balance
52 Adjusting the recording level manually – Sound recording level You can adjust the recording sound level. Use headphones to monitor the sound when you adjust it. You can adjust the channel 1 and channel 2 separately. Selecting the channel to be adjusted manually (1)Set the POWER switch to CAMERA or VCR. (2)Press MENU to display the menu. (3)Turn the SEL/PUSH EXEC dial to select , then press the dial. (4)Turn the SEL/PUSH EXEC dial to select AUDIO SET, then press the dial. (5)Turn the SEL/PUSH EXEC dial to select the desired item, then press the dial. (6)Turn the SEL/PUSH EXEC dial to select the setting of the item, then press the dial. (7)Press MENU to erase the menu display. Items to be adjusted Item AGC CH1 AGC CH2a) MAN GAINa)b) a) This is only available when connecting the external microphone to the INPUT2 connector. b) LINKED is only available when both AGC CH1 and AGC CH2 are set to OFF.Meaning Switches the recording level adjustment of the channel 1 from automatic (ON) and manual (OFF). Switches the recording level adjustment of the channel 2 from automatic (ON) and manual (OFF). Sets the recording levels of channel 1 and channel 2 linked (LINKED) or separated (SEPARATED). Setting ON OFF ON OFF SEPARATED LINKED 5,6TAPE SET AUD I O SET AGC CH1 AGC CH2 MAN GA I N RETURNON OFF [ MENU] : END [ MENU] : END TAPE SET AUD I O SET AGC CH1 AGC CH2 MAN GA I N RETURNOFF [ MENU] : END 1 2,7 3,4 POWER OFF (CHG)CAMERA MEMORY VCR TAPE SET REC MODE AUD I O MODE REMA I N M I C NR AUD I O SET [ MENU] : END [ MENU] : ENDTAPE SET AUD I O SET AGC CH1 AGC CH2 MAN GA I N RETURNON [ MENU] : END MENU
53 Advanced Recording Operations Adjusting the recording level manually– Sound recording level To adjust the recording level automaticallySet AGC CH1 to ON when you automatically adjust the recording level of the channel 1. And set AGC CH2 to ON when you automatically adjust the recording level of the channel 2. When the recording level is adjusted manually The recording level indicator appears at the lower-right on the LCD screen or in the viewfinder. The sound input through the AUDIO CH1/CH2 jacks or DV IN/OUT jack You cannot adjust the recording level. Adjusting the recording level (1)Press AUDIO LEVEL to display the recording level adjustment display in standby or recording mode. (2)Turn the SEL/PUSH EXEC dial to adjust the recording level of the channel 1, then press the dial. The cursor moves to “CH2,” and you can adjust the recording level of the channel 2. (3)Turn the SEL/PUSH EXEC dial to adjust the recording level of the channel 2. [a]Recording level meter [b]Decreases the recording level [c]Increases the recording level To clear the recording level adjustment displayPress AUDIO LEVEL again. When AGC CH1 or AGC CH2 is set to ON You can see the recording level adjustment display, however, you cannot adjust the recording level of the channel that the item above is set to ON. When MAN GAIN is set to LINKED The recording level adjustment display is changed as follows. 3 1,2 [a] [b] [c]AUDIO LEVEL30 20 12 0 dB CH1 CH2 CH1 CH2 30 20 12 0 dB CH1 CH2 CH1 CH2 30 20 12 0 dB CH1 CH2 CH1,2
54 Connecting an optional external microphone You can get your desired audio quality, connecting multiple microphones or an optional microphone to your camcorder. (1)Loosen the microphone holder screw and open the cover. (2)Detach the supplied microphone and unplug the cable from the camcorder. (3)Connect the microphone (not supplied) to the INPUT1 or INPUT2 connector. (4)Select the channel to be used, using the REC CH SELECT switch. Used channels according to the position of the REC CH SELECT switch are as follows: Audio input through The position of the REC CH The audio is recorded onSELECT switch INPUT1 CH1 Channel 1 CH1•CH2 Channels 1/2 INPUT2 CH1 Channel 2 CH1•CH2— (5)Set the following settings. When connecting a microphone Set the INPUT LEVEL selector to MIC or MIC ATT. When set to MIC ATT, you can reduce the volume by about +20 dB. And set the +48V switch to ON if the microphone is powered through its cable. When connecting audio equipment Set the +48 V switch to OFF and set the INPUT LEVEL selector to LINE. 1,2 4,53 CH1•CH2 REC CH SELECTINPUT LEVEL+48VINPUT LEVEL+48V CH1LINE MICON OFFLINE MIC ATTMIC ATT MICON OFF INPUT1 INPUT2 REC CH SELECTINPUT LEVEL+48V INPUT2 REC CH SELECT+48 V INPUT LEVEL
55 Advanced Recording Operations Connecting an optional external microphone When the wind is blowing hard Set CH1 or CH2 of WIND to ON in the menu settings according to the input (p. 104). We recommend that you set MIC NR to OFF in the menu settings in the following cases: •When you use the external microphone at a distance from the camcorder. •When the REC CH SELECT switch is set to CH1 and you will not record any audio via the INPUT2 connector. •When you set the INPUT LEVEL selector to LINE. When you unplug the microphone plug Unplug it while holding the PUSH button down. Notes •When you use an external microphone, make sure that the wind screen does not appear on the screen, using an underscan monitor. •If you use equipment other than a 48-V microphone with the +48V switch set to ON, a malfunction of the equipment may occur. When you connect equipment other than a 48-V microphone, set it to OFF.
56 Presetting the adjustment for picture quality – Custom preset You can preset the camcorder to record the picture with the desired picture quality. When presetting, adjust the picture by shooting a subject and checking the picture displayed on a TV using the menu settings. (1)Press CUSTOM PRESET to display the CUSTOM PRESET menu in standby or memory mode. (2)Press the SEL/PUSH EXEC dial. (3)Turn the SEL/PUSH EXEC dial to select SET, then press the dial. (4)Turn the SEL/PUSH EXEC dial to select ON, then press the dial. (5)Turn the SEL/PUSH EXEC dial to select the desired item, then press the dial. (6)Turn the SEL/PUSH EXEC dial to adjust the selected item, then press the dial. (7)Press CUSTOM PRESET. The CUSTOM PRESET menu disappears and the indicator appears on the LCD screen or in the viewfinder. 2-4 5,61 7 CUSTOM PRESET [ CP] : ENDCUSTOM PRESET STBY [ CP] : ENDCUSTOM PRESET STBY SET COLOR LVL SHARPNESS WB SH I FT AGC LIMIT RESET RETURNOFF [ CP] : END CUSTOM PRESET STBY SET COLOR LVL SHARPNESS WB SH I FT AGC LIMIT RESET RETURNOFF ON [ CP] : END CUSTOM PRESET STBY SET COLOR LVL SHARPNESS WB SH I FT AGC LIMIT RESET RETURNON [ CP] : END CUSTOM PRESET STBY SET COLOR LVL SHARPNESS WB SH I FT AGC LIMIT RESET RETURN [ CP] : END CUSTOM PRESET STBY COLOR LVL [ CP] : END SET COLOR LVL SHARPNESS WB SH I FT AGC LIMIT RESETOFF OFFCUSTOM PRESET CUSTOM PRESET
57 Advanced Recording Operations Presetting the adjustment for picture quality Items to be adjusted Item COLOR LVL SHARPNESS WB SHIFT AGC LIMIT RESET To cancel using the custom presetSelect OFF in step 4, then press the SEL/PUSH EXEC dial. To return to the standard settingSelect OK from the RESET item in step 5, then press the SEL/PUSH EXEC dial. To cancel, select RETURN, then press the SEL/PUSH EXEC dial. To check the custom preset settingPress CUSTOM PRESET while the camcorder is in standby, recording or memory mode. The custom preset setting appears on the LCD screen or in the viewfinder. About the AGC limit When adjusting the gain manually, the level of the gain is up to 18 dB (OFF). When you preset the desired picture quality in CAMERA or memory mode The preset is only available in each mode you preset. If you want to use a preset both in CAMERA and memory modes, you have to preset in each mode.Meaning Color intensity Sharpness White balance Auto Gain-limit Sets items above to the default settings.Adjustment value Decreases color intensity y Increases color intensity Softer y Sharper Bluish y Reddish 6 dB/12 dB/OFF
58 Focusing manually You can gain better results by manually adjusting the focus in the following cases: •The autofocus mode is not effective when shooting –subjects through glass coated with water droplets –horizontal stripes –subjects with little contrast with backgrounds such as walls and sky •When you want to change the focus from a subject in the foreground to a subject in the background •Shooting a stationary subject when using a tripod (1)Slide FOCUS down to MANUAL. The 9 indicator appears on the LCD screen or in the viewfinder in recording, standby, or memory mode. (2)Turn the focus ring to sharpen the focus. To return to the autofocus modeSlide FOCUS up to AUTO to turn off the 9 or indicator. To focus in infinitySlide FOCUS to INFINITY. The indicator appears on the LCD screen or in the viewfinder. This function is useful when the nearer subject is focused automatically, even though you want to focus on a faraway subject. To shoot with auto focusing momentarilyPress PUSH AUTO. The auto focus functions while you are pressing PUSH AUTO. Use this button to focus on one subject and then another with smooth focusing. When you release PUSH AUTO, manual focusing resumes. To obtain the correct focusFirst, focus on a subject manually with the zoom set toward the “T” (telephoto) side, then adjust the zoom by pressing the “W” side of the lever gradually. When you shoot close to the subject Focus at the end of the “W” (wide-angle) position. 9 changes as follows: when recording a distant subject. when the subject is too close to focus on. 2 PUSH AUTO FOCUS MAN AUTO INFINITY 1
59 Advanced Recording Operations Interval recording You can make a time-lapse recording by setting the camcorder to automatically record and standby sequentially. You can achieve an excellent recording for flowering, emergence, etc., with this function. [a]Recording time [b]Waiting time (1)Press MENU to display the menu in standby mode. (2)Turn the SEL/PUSH EXEC dial to select , then press the dial. (3)Turn the SEL/PUSH EXEC dial to select INT. REC, then press the dial. (4)Turn the SEL/PUSH EXEC dial to select SET, then press the dial. (5)Set INTERVAL and REC TIME. 1 Turn the SEL/PUSH EXEC dial to select INTERVAL, then press the dial. 2 Turn the SEL/PUSH EXEC dial to select the desired interval time, then press the dial. The time: 30SEC y 1MIN y 5MIN y 10MIN. 3 Turn the SEL/PUSH EXEC dial to select REC TIME, then press the dial. 4 Turn the SEL/PUSH EXEC dial to select the desired recording time, then press the dial. The time: 0.5SEC y 1SEC y 1.5SEC y 2SEC. 5 Turn the SEL/PUSH EXEC dial to select RETURN, then press the dial. 15 2-4 12 34 CAMERA SET D ZOOM 16 : 9W I DE STEADYSHOT FRAME REC I NT. REC W I ND [ MENU] : END CAMERA SET D ZOOM 16 : 9W I DE STEADYSHOT FRAME REC I NT. REC W I ND RETURNOFF [ MENU] : END CAMERA SET I NT. REC I NTERVAL REC T I ME RETURN 30SEC [ MENU] : END CAMERA SET I NT. REC I NTERVAL REC T I ME RETURN 30SEC 1M I N 5M I N 10M I N [ MENU] : END CAMERA SET I NT. REC I NTERVAL REC T I ME RETURN 0 . 5SEC [ MENU] : END CAMERA SET I NT. REC I NTERVAL REC T I ME RETURN 0 . 5SEC 1SEC 1 . 5SEC 2SEC [ MENU] : END CAMERA SET D ZOOM 16 : 9W I DE STEADYSHOT FRAME REC I NT. REC W I ND RETURNON OFF SET [ MENU] : END MENU 10 min 10 min 1 s 1 s 9 min 59 s 9 min 59 s [a][a] [b][b] Example
60 Interval recording (6)Turn the SEL/PUSH EXEC dial to select ON, then press the dial. (7)Press MENU to erase the menu display. The interval recording indicator flashes. (8)Press START/STOP to start interval recording. The interval recording indicator lights up. To cancel the interval recording•Set INT. REC to OFF in the menu settings. •Set the POWER switch to OFF (CHG), VCR or MEMORY. To stop the interval recording momentarily and perform normal recording Press START/STOP. You can perform normal recording only once. To cancel the normal recording, press START/STOP again. Note on interval recording You cannot do interval recording in memory mode. On recording time There may be a discrepancy in recording time of up to +/– 6 frames from the selected time. Even if you press INDEX MARK during interval recording You cannot mark an index. 7 68 POWER OFF (CHG)CAMERA MEMORY VCR I NTERVALMENU CAMERA SET D ZOOM 16 : 9W I DE STEADYSHOT FRAME REC I NT. REC W I ND RETURNON [ MENU] : END