Page 151
5-48 Address 16 17 63 84 C5 55 75 07 D3 D6 59 01 FF D0 Data Address 41 42 Data 26 A1 Address 16 17 86 35 33 AA 90 B6 Data Address 41 42 Data 69 73 3-5-2. BIST Check 1. Playback System Check 1-1. Preparation for Playback 1) Set the POWER switch to VTR (or PLAYER) position. 2) Connect the adjusting remote commander and set the HOLD switch to ON (SERVICE) position. 3) Playback the BIST check tape. (XH5-6(NTSC), XH5-6P(PAL)) Note: Perform the following checks in the playback mode. 1-2. IC1814(TRF) BIST(PB)...
Page 152
5-49 Address 16 17 Data 9A 13 Address 14 15 Data 12 43 Address 16 17 Data FB F4 1-4. IC1600(SFD) BIST(PB) Check 1) Select page: 0, address: 01, and set data: 01. 2) Select page: C, address: AC, set data: 21, and press the PAUSE button. 3) Select page: C, address: AD, set data: 01, and press the PAUSE button. 4) Select page: 3, address: 11, set data: 04, and press the PAUSE button. 5) Select page: 3, address: 12, set data: 08, and press the PAUSE button. 6) Select page: 3, address: 12, set data: 00, and...
Page 153
5-50 ¥ UPY Cr BIST(PB) Check 14) Select page: 3, address: 10, set data: 89, and press the PAUSE button. 15) Select page: 3, address: 12, set data: 10, and press the PAUSE button. 16) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 17) Select page: 3, address: 13, set data: 04, and press the PAUSE button. 18) When the playback system from IC1501(VFD) to IC5001,5502 (LCD DRIVER) is normal, the display data (combination data) of page: 3, address: 16 and 17 agrees with any combination...
Page 154
5-51 Address 1A 1B Data D5 0B C2 42 A7 DD DataAddress 41 42 Address 1A 1B Data 34 8A 55 B5 1A 04 DataAddress 41 42 2D F5 A2 7B DataAddress 16 17 6C C7 23 76 DataAddress 18 19 2. Recording System Check 2-1. Preparations for recording 1) Playback the BIST check tape.(XH5-6(NTSC), XH5-6P(PAL)) 2) Select page: 3, address: 10, set data: C0, and press the PAUSE button. 3) Select page: 3, address: 11, set data: 07, and press the PAUSE button. 4) Enter the stop mode. 5) While keep the HOLD switch of the...
Page 155
5-52 13) Select page: 3, address: 40, set data: 01, and press the PAUSE button. 14) Select page: 3, address: 40, set data: 00, and press the PAUSE button. 15) When the recording system from IC1601 (TFD) to IC1900 (TRX) is normal, the display data (combination data) of page: 3, address: 43 and 44 agrees with any combination as shown below. NTSC model PAL model 2-5. IC1900(TRX) BIST(REC) Check 1) Select page: 3, address: 12, set data: 04, and press the PAUSE button. 2) Select page: 3, address: 12, set...
Page 156
5-53 3-6. IR TRANSMITTER ADJUSTMENTS Adjust using a IR receiver jig (J-6082-383-A). Switch setting: LASER LINK ................................... ON (Red LED is lit) 1. IR Video Carrier Frequency Adjustment (VI-151 board) Mode VTR stop Signal Arbitrary Measurement PointPin 5 of CN003 of IR receiver jig (RF) (Or Pin !¤ of IC1403) Measuring Instrument Frequency counter Adjustment Page C Adjustment Address 28 Specified Value f = 11.85 ± 0.05 MHz Connection of Equipment Connect the measuring device as...
Page 157
5-54 3. IR Audio Deviation Adjustment (VI-151 board) Mode VTR stop Signal Video : No signal Audio : Ð400Hz, Ð7.5dBs, Audio left and right terminal of AUDIO/VIDEO jack Measurement Point AUDIO L terminal and AUDIO R terminal of IR receiver jig (Terminated at 47kW) Measuring Instrument Audio level meter Adjustment Page C Adjustment Address 2A Specified Value Signal level: Ð7.5 ± 1.0 dBs Level difference of L and R: Below 2dB Connection of Equipment: Connect the measuring device as shown in the following...
Page 158
5-55 3-7. AUDIO SYSTEM ADJUSTMENTS [Connection of Audio System Measuring Devices] Connect the audio system measuring devices as shown in Fig. 5-3-13. Fig. 5-3-13 Recording (Camera mode) Audio oscillator Attenuator600 ½Left RightMain unit MIC 600 ½: 270 ½ (1-249-410-11) + 330 ½ (1-249-411-11) Main unit AUDIO/ VIDEO OUTLeft (White) Right 47k ½ 47k ½ Video (Yellow)TV monitor Audio level meter or Distortion meter 47k ½ (1-249-437-11) Playback (Red)
Page 159
5-56 1. Playback Level Check Mode VTR playback Signal Alignment tape: For audio operation check (XH5-3 (NTSC)) (XH5-3P (PAL)) Measurement Point Audio left or right terminal of AUDIO VIDEO jack Measuring Instrument Audio level meter and frequency counter Specified Value 32 kHz mode: 1 kHz, +3.0 ± 2.0dBs 48 kHz mode: 1 kHz, +3.0 ± 2.0dBs 44.1 kHz mode: The 7.35kHz signal level during EMP OFF is +2.0 ± 2.0dBs. The 7.35kHz signal level during EMP ON is Ð6 ± 2 dB from the signal level during EMP OFF. Checking...
Page 160
5-57 5-4. SERVICE MODE 4-1. ADJUSTMENT REMOTE COMMANDER The adjustment remote commander is used for changing the calculation coefficient in signal processing, EVR data, etc. The adjustment remote commander performs bi-directional communication with the unit using the remote commander signal line (LANC). The resultant data of this bi-directional communication is written in the non-volatile memory. 1. Using the adjustment remote commander 1) Connect the adjustment remote commander to the LANC terminal. 2)...