Page 111

5-8
Address
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
Initial value
NTSC
80
80
D5
EC
20
20
PA L
80
80
D5
EC
20
20
Remark
Fixed data-1
(Initialized data)
PSD sensor gain adj.
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Color reproduction adj. (2)
(ND filter ON)
Fixed data-1
Fixed...

Page 112

5-9
Address
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C to FF
Initial value
NTSCPA LRemark
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Table. 5-1-2 

Page 113

5-10 1-3. CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified value of ÒComposite Output Y Level AdjustmentÓ and
ÒComposite Output Chroma Level AdjustmentÓ of ÒBase band Block
AdjustmentÓ of ÒVIDEO SYSTEM ADJUSTMENTÓ are satisfied.
1. 27 MHz Origin Oscillation Adjustment (VC-208 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject Not required
Measurement...

Page 114

5-11
3. Offset Adjustment
Adjust so that the AGC OUT potential lies within the specified value
of the digital clamp.
Subject Not required
Measurement Point DDS display data of LCD or TV
monitor (Note 1)
Measuring Instrument
Adjustment Page E
Adjustment Address 2D, 2E, 2F
Specified Value 50 to B0
Note 1: DDS display data of LCD or TV monitor.
CA 00 0000
CA 00 00
XX
         Object data
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 11, set data: 02, and...

Page 115

5-12
Address
24
25
26
27
28
29
36
PA L
2C
17
78
1D
FB
12
D6
Address
37
38
39
3A
3B
3C
3D
PA L
E6
23
00
19
00
27
A8
4. Flange Back Adjustment
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
4-1. Flange Back Adjustment(1)
Subject Flange back adjustment chart
(2.0 m from the front of the lens)
(Luminance: 230 ± 30 lux)
Measurement Point Check operation on TV monitor
Measuring Instrument
Adjustment...

Page 116

5-13
A=B
C=D
ABC
D
t=0 ± 0.1msec
V
Color bar chart picture frame
TV monitor picture frame
5. Flange Back Check
Subject Siemens star
(2.0 m from the front of the lens)
(Luminance: 300 ± 50 lux)
Measurement Point Check operation on TV monitor
Measuring Instrument
Specified Value Focused at the TELE end and WIDE
end.
Switch setting:
1) DIGITAL ZOOM (Menu display) ................................... OFF
Checking method:
1) Place the Siemens star 2.0m from the front of the lens.
3) Shoot the Siemens star with...

Page 117

5-14
7. Pre White Balance Data Input
At 3200k, input the pre white balance standard data.
Subject Clear chart
(Color bar standard picture frame)
Adjustment Page E
Adjustment Address 2A, 2B
Switch setting:
1) ND filter ........................................................................... OFF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 1C, and set data: 02.
3) Select page: F, address: 20, and set data: 00, and press the
PAUSE button of the...

Page 118

5-15
9. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject Clear chart
(Color bar standard picture frame)
(95cm from the front of the lens)
Adjustment Page F
Adjustment Address 2C
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 96, and set data: 00.
3) Select page: 6, address: 97, and set data: 2C.
4) Select page: 6, address: 01,...

Page 119

5-16
11. White Balance ND Filter Compensation Adjustment
Compensate the white balance deviation when ND filter is ON.
Subject Clear chart
(Color bar standard picture frame)
Adjustment Page F
Adjustment Address 4A, 4B
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 1C, and set data: 03.
3) Wait for 2 seconds.
4) Select page: 6, address: 01, and set data: 11, and press the
PAUSE button of the adjustment remote commander.
5) Select page: 6, address: 01, and...

Page 120

5-17
13. Color Reproduction Adjustment (ND Filter OFF)
When the ND filter is off, adjust the color difference matrix
coefficient so that proper color reproduction is produced.
Subject Color bar chart standard picture frame
Measurement Point Video output terminal
Measuring Instrument Vectorscope
Adjustment Page F
Adjustment Address 44, 45, 46, 47
Specified Value All color luminance points should
settle within each color reproduction
frame.
Adjusting method:
1) Select page: 0, address: 01, and set data:...
Start reading Sony Dcrtrv890e Manual