29 
  
3.2 Burner and nozzle characteristics table 
 Burner Rated heating capacity (kW) 
 LPG – G30/G31  30/37 mbar 
  Nozzle diameter 1/100 mm 
By-pass mm 1/100 
Reduced flow rate (W) 
Flow rate  g/h G30 Flow rate g/h G31 
Auxiliary (1) 1.05 50 30 * 27/28 ** 400 76 75 
Semi rapid (2) 1.75 63 30 * 32/33 ** 500 127 125 
Ultra Rapid (3) 3.9 100 65 *63/65 ** 1600 284 279 
*/**: diameters marked * and ** must be fitted respectively on valves marked * and 
**shown in...

Page 12

 
 
Instructions for the installer 
  
30   
4 FINAL OPERATIONS 
After carrying out the above adjustments, remount in reverse order to the 
instructions given in paragraph “3.1 Replacement of nozzles on the hob”. 
  
 
 After having regulated the device with gas other than the one tested, 
replace the label located on the guard with the one that corresponds to 
the new gas. 
The label is available from your nearest Authorised Assistance Centre.   
 
4.1 Regulation of minimum for town gas and natural gas...

Page 13

 
 
Instructions for the user  
 
31   
5 USING THE  HOB 
 5.1 Ignition of the burners 
  
Before turning on the burners, make sure that the flame-spreader crowns 
and respective caps are properly fitted in their housings. Ensure the 
flame-spreader holes A are aligned with the ignition plugs and the 
thermocouples.
  
To prevent damage to the work top, the hob comes complete with a 
raised pan stand H. This must be placed under pans with a diameter 
bigger than those indicated in the table in paragraph...

Page 14

 
 
Instructions for the user 
  
32 
5.2 Practical advice for using the burners 
 
For better use of the burners and lower gas consumption, use covered 
cooking receptacles that have a flat, smooth bottom and are proportional 
in size to the burner to prevent the flame from licking the sides (see 
paragraph “5.3 Pan diameters”). When water reaches boiling point, lower 
the flame so that it does not boil over.  
 
To avoid burns or damage to the worktop, all receptacles must be placed 
within the...

Page 15

 
 
Instructions for the user  
 
33   
6 CLEANING AND MAINTENANCE 
 
 
Before any intervention, disconnect the appliance from the mains. 
 
 
Never use a steam jet to clean the appliance. 
 
6.1 Cleaning the stainless steel 
 
 To keep stainless steel in good condition it should be cleaned regularly 
after use. Let it cool first. 
6.1.1 Routine daily cleaning 
To clean and preserve the stainless steel surfaces, always use only 
specific products that do not contain abrasives or chlorine-based acids....

Page 16

 
 
Instructions for the user 
  
34 
  
 
  In models with central pan stand, fit this piece, taking care that its centre is
perfectly aligned with the centre of the burner 
  