Smeg Pgf75-4 Manual
Have a look at the manual Smeg Pgf75-4 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 81 Smeg manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Contents 19 1 INSTRUCTIONS FOR SAFE AND PROPER USE _______________ 20 2 POSITIONING OF THE HOB _______________________________ 22 3 ADJUSTMENT TO DIFFERENT TYPES OF GAS _______________ 28 4 FINAL OPERATIONS _____________________________________ 30 5 USING THE HOB ________________________________________ 31 6 CLEANING AND MAINTENANCE ___________________________ 33 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL. INSTRUCTIONS FOR THE INSTALLER: these are for the qualified technician who must carry out a suitable check of the gas system, install the appliance, set it functioning and carry out an inspection test. INSTRUCTIONS FOR THE USER : these contain user advice, description of the commands and the correct procedures for cleaning and maintenance of the appliance.
Introduction 20 1 INSTRUCTIONS FOR SAFE AND PROPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE HOB. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE HOB. ALSO KEEP THE SERIES OF NOZZLES SUPPLIED. INSTALLATION MUST BE CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN FORCE. THIS APPLIANCE IS INTENDED FOR DOMESTIC USES AND CONFORMS TO EEC DIRECTIVES CURRENTLY IN FORCE. THE APPLIANCE IS DESIGNED TO CARRY OUT THE FOLLOWING FUNCTIONS: COOKING AND HEATING FOOD; ALL OTHER USES ARE TO BE CONSIDERED IMPROPER. THE MANUFACTURER DECLINES ALL LIABILITY FOR IMPROPER USE . DO NOT LEAVE THE PACKAGING MATERIALS UNATTENDED IN THE HOME ENVIRONMENT. SEPARATE THE DIFFERENT WASTE MATERIALS FROM THE PACKAGING AND DELIVER THEM TO THE NEAREST COLLECTION CENTRE FOR RECYCLABLE WASTE. REGULATIONS REQUIRE THAT THE APPLIANCE IS EARTHED IN ACCORDANCE WITH ELECTRICAL SAFETY REGULATIONS. THE PLUG TO BE CONNECTED TO THE POWER SUPPLY CABLE AND THE SOCKET MUST BE OF THE SAME TYPE AND MUST CONFORM TO CURRENT REGULATIONS. THE POWER SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN. NEVER UNPLUG THE APPLIANCE BY PULLING THE POWER SUPPLY CABLE. IMMEDIATELY AFTER INSTALLATION, CARRY OUT A BRIEF INSPECTION TEST OF THE APPLIANCE, FOLLOWING THE INSTRUCTIONS BELOW. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE POWER SUPPLY AND CONTACT YOUR NEAREST TECHNICAL ASSISTANCE CENTRE. NEVER ATTEMPT TO REPAIR THE APPLIANCE YOURSELF. ALWAYS CHECK THAT THE CONTROL KNOBS ARE IN THE POSITION (OFF) WHEN YOU FINISH USING THE HOB.
Introduction 21 THE APPLIANCE DATA PLATE, WITH TECHNICAL DATA, REGISTRATION NUMBER AND BRAND NAME, IS POSITIONED AT A VISIBLE POINT UNDER THE SAFETY COVER. THE DATA PLATE ON THE PROTECTIVE COVER MUST NEVER BE REMOVED. DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE HOB PANSTAND GRIDS. DO NOT USE COOKING RECEPTACLES THAT EXTEND BEYOND THE OUTSIDE PERIMETER OF THE HOB. THE APPLIANCE IS DESIGNED FOR USE BY ADULTS. DO NOT ALLOW CHILDREN TO GO NEAR OR PLAY WITH IT. THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002/96/EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE). THIS GUIDELINE IS THE FRAME OF A EUROPEAN-WIDE VALIDITY OF RETURN AND RECYCLING ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT. The manufacturer declines all liability for injury to persons or animals and for damage to property resulting from non-observance of the above prescriptions or from tampering with any part of the appliance or for the use of non-original spare parts.
Instructions for the installer 22 2 POSITIONING OF THE HOB The following operation requires building and/or carpentry work so must be carried out by a competent tradesman. Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminated wood, as long as they are heat-resistant (T 90°C). 2.1 Attachment to support structure, traditional built-in model Create an opening with the dimensions shown in the figure in the work surface. A (mm) B (mm) C (mm) D (mm) E (mm) L (mm) X (mm) Y (mm) min 110 min 460 min 750 20÷50 min 50 700 492 700 Carefully position the gasket provided all around the outer edge of the hole in the work surface as shown in figure 2, pressing it down lightly to ensure it adheres properly. The front and rear sides of the gasket must skim the hole. Now place the hob on the insulating gasket and use the screws and fixing brackets (fig. 4) to secure the hob to the supporting structure, adjusting it until perfectly horizontal. Carefully trim off the excess edge of the gasket C (Fig.3). The dimensions in figure 2 below refer to the distance between the hole and the inside edge of the gasket. Do not fit the brackets shown in fig. 4 until the hob has been set in place.
Instructions for the installer 23 2) 3) 4) 2.2 Attachment to support structure, flush-mounting model Create an opening with the dimensions shown in the figure. A (mm) B (mm) C (mm) D (mm) E (mm) L (mm) X (mm) Y (mm) min 110 min 460 min 750 20÷40 min 50 700 492 700 This type of appliance also requires a cut 3 mm deep in the work-top with the dimensions shown in figure 4 (detail A, figure 2). Before positioning the hob, position the adhesive sponge material “E” supplied over the milled surface (fig. 2). Now place the hob on the cut in the work-top and use the screws and fixing brackets (sequence shown in Fig. 3) to secure the hob to the supporting structure, adjusting it until perfectly horizontal. Do not fit the brackets shown in fig. 3 until the hob has been set in place.
Instructions for the installer 24 2) 3) 4) 3A Apply a layer of “waterproof primer” to the milled surface. Important: Other types of installation will only be possible under the manufacturers supervision. Overall dimensions: location of gas and electrical connection points (all measures in mm). Warning: the bottom surface of the hob can become very hot. To avoid a hazard, under-bench access must be restricted. Refer to installation instruction
Instructions for the installer 25 IMPORTANT: when installing the appliance above a cupboard, a dividing shelf, as shown above, must be installed. If installed above an under-bench oven, this is not required. Installation of an oven without cooking fan underneath the hob is forbidden. 2.3 Electrical connection Make sure that the voltage and capacity of the power supply cable conform to the data shown on the plate located under the protective cover. Do not remove this plate for any reason. The power supply cable plug and the wall socket must be of the same type and conform to the current electrical system regulations. Check that the power line is adequately earthed. On the power line, install an all-pole disconnect switch with minimum contact gap of 3 mm located at an easily accessible position near the appliance. Do not use reducers, adapters or shunts.
Instructions for the installer 26 If the power cable is to be replaced, the wire section on the new cable must not be less than 0.75 mm2 (3 x 0.75 cable), bearing in mind that the end to be connected to the appliance must have the earth wire (yellow-green) at least 20 mm longer. Use only H05V2V2-F cable or similar which has a maximum temperature of 90°C. Any replacement needed should be carried out by a specialised technician who should make the mains connections according to the following diagram. L = brown N = blue = yellow-green The manufacturer declines all liability for injury to persons or animals and for damage to property resulting from non-observance of the above prescriptions or from tampering with any part of the appliance. 2.4 Ventilation requirements The appliance may be installed only in rooms with permanent ventilation, as required by standards regulations in force. The room in which the appliance is installed must have sufficient air flow to satisfy the requirements of normal gas combustion and of necessary air exchange in the room. The air intakes, protected by grills, must be appropriately sized and placed so as not to be blocked in any way. The room must be suitably ventilated to avoid overheating or excess humidity produced by cooking; after any prolonged use, a window should be opened or the speed of any fans should be increased. 2.5 Discharge of combustion products Discharge of combustion products must be guaranteed by means of hoods connected to a natural draught flue with certain efficiency, or by means of forced aspiration. An efficient aspiration system requires careful planning by a qualified specialist, respecting the positions and distances prescribed by standards. After installation, the installer must issue a certificate of conformity.
Instructions for the installer 27 2.6 Gas connection Connection to the gas mains may be made with a rigid copper pipe or with a flexible pipe conforming to the provisions defined by standard regulations in force. After connection operations, check for leaks using a soapy solution. The hob has been inspected for G20 natural gas (2H) at a pressure of 20 mbar. For use with other types of gas, see chapter “3. ADJUSTMENT TO DIFFERENT TYPES OF GAS. The hose connection at the rear of the appliance has a ½” internal thread (ISO 228-1). Connection with rigid copper pipe: the connection to the gas mains must not provoke stress of any kind on the appliance. Connection may be made by using biconical adapter D with insertion of gasket C supplied. Connection with flexible steel pipe: use only flexible stainless steel pipes conforming to standard regulations, in force inserting gasket C supplied between the fitting A and the flexible pipe B. The flexible pipe must be installed so that pipe length does not exceed 2 meters of maximum extension. Make sure that the pipes do not touch any moving parts or become crushed. 2.7 Connection to LPG Use a pressure regulator and make the connection to the tank according to the provisions of standard regulations in force. Make sure that feed pressure conforms to the levels shown in the table in paragraph “3.2 Burner and nozzle characteristics table
Instructions for the installer 28 3 ADJUSTMENT TO DIFFERENT TYPES OF GAS Before performing any cleaning or maintenance work, unplug the appliance from the mains. The hob is set for natural gas G20 (2H) at a pressure of 20 mbar. In the case of functioning with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described below. 3.1 Replacement of nozzles on the hob 1. Remove the grids and all the caps and flame-spreader crowns; 2. Unscrew the burner nozzles with a 7 mm socket wrench; 3. Replace the nozzles according to the type of gas to be used (see paragraph “3.2 Burner and nozzle characteristics table”). 4. Replace the burners in the correct position. Nozzles for town gas (G110 – 8 mbar) are available from authorized assistance centres.