Smeg A3-6 Manual
Here you can view all the pages of manual Smeg A3-6 Manual. The Smeg manuals for Cooker are available online for free. You can easily download all the documents as PDF.
Page 1
Contents 1. INSTRUCTIONS FOR SAFE AND PROPER USE _______________ 44 2. INSTALLING TH E APPLIANCE _____________________________ 46 3. ADAPTATION TO DIFFERENT TYPES OF GAS _______________ 50 4. FINAL OPERATIONS _____________________________________ 52 5. DESCRIPTION OF CONTROLS ____________________________ 54 6. USING THE COOKING HOB _______________________________ 61 7. USING THE OVENS______________________________________ 63 8. AVAILABLE ACC ESSORIES _______________________________ 65 9....
Page 2
Introduction 1. INSTRUCTIONS FOR SAFE AND PROPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE COOKER. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE COOKER. ALSO KEEP THE SERIES OF NOZZLES SUPPLIED. INSTALLATION MUST BE CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN FORCE. THIS APPLIANCE IS INTENDED FOR DOMESTIC USES...
Page 3
Introduction DURING USE THE APPLIANCE BECOMES VERY HOT. TAKE CARE NOT TO TOUCH THE HEATING ELEMENTS INSIDE THE OVEN. DO NOT INSTALL THIS APPLIANCE ON A RAISED PLATFORM. DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE COOKING HOB PAN STANDS. DO NOT USE CONTAINERS OR BROILERS THAT EXTEND BEYOND THE OUTER PERIMETER OF THE HOB. THE USE OF THIS APPLIANCE IS NOT PERMITTED TO PEOPLE (INCLUDING CHILDREN) OF REDUCED PHYSICAL AND MENTAL ABILITY, OR LACKING IN...
Page 4
Instructions for the installer 46 2. INSTALLING THE APPLIANCE It is the law that all gas appliances are installed by competent persons. Corgi gas installers are approved to work to safe and satisfactory standards. All gas installation, servicing and repair work must be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990. It can be placed against walls higher th an the hob, at a distance of at least 50 mm from the side of the appliance, as shown in the...
Page 5
Instructions for the installer 2.2 Electrical connection Make sure the voltage and the cross-section of the power supply line match the specifications indicated on the identification plate positioned in the storage compartment. Do not remove this plate for any reason. The plug at the end of the power cabl e and the wall socket must be the same type (conforming to regulations in force). Check that the power line is adequately grounded. Do not us e reducers, adapters or shunts....
Page 6
Instructions for the installer 48 For operation on 380-415V3N∼: use a H05RR-F-type five-core cable (5 x 1.5 mm2). For operation on 380-415V2N∼: use a H05RR-F-type four-core cable (4 x 2.5 mm2). For operation on 220-240V∼:use n H05RR-F-type three-core cable (3 x 4 mm2). The cable end to be connected to the appliance must be provided with a ground wire (yellow-green) at least 20 mm longer. The manufacturer cannot be held liable for damage to persons...
Page 7
Instructions for the installer 2.3 Ventilation requirements The room containing the appliance should ha ve an air supply in accordance with B.S. 5440 part 2 1989. 1. All rooms require an opening window or equivalent, and some rooms will require a permanent vent as well. 2. For room volumes up to 5 m3 an air vent of 100 cm2 is required. 3. If the room has a door that opens directly to the outside, and the room exceeds 1 m3 no air vent is required. 4. For room volumes between 5 m3 and 10...
Page 8
Instructions for the installer 50 3. ADAPTATION TO DIFFERENT TYPES OF GAS Before carrying out the following operations, disconnect the appliance from the electricity supply. The cooking hob of the co oker is preset for G20 natural gas at a pressure of 20 mbar. In the case of functioning with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. Replace the burner nozzles as indicated in the table of the gas to be used. 3.1...
Page 9
Instructions for the installer 3.2 Burner and nozzle characteristics table Burner Rated heating capacity (kW) LPG – G30/G31 28/37 mbar (drawing ref. X238) Nozzle diameter1/100 mm Reduced capacity (W) Capacity g/h G30 Capacity g/h G31 Auxiliary 1.05 50 400 76 75 Semi rapid 1.8 65 500 131 129 Rapid 3.0 85 800 218 214 Fish Burner 1.9 68 800 138 136 Ultra rapid 3.9 100 1600 284 279 Burner Rated heating capacity (kW) NATURAL GAS – G20 20 mbar Nozzle diameter 1/100...
Page 10
Instructions for the installer 52 4. FINAL OPERATIONS After replacing the nozzles, repositi on the flame-spreader crowns, the burner caps and the pan stands. Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the appliance with the one corresponding to the new gas. This label is in the packet together with the nozzles. 4.1 Adjustment of minimum for natural gas Light the burner and turn it to the minimum position . Extract the...