    Input screen for keycode To cancel the keycode that you have already
    set
    •Press R on the projector for four times in steps
    4 and 5 above.
    When the System Lock is set•When System Lock is set, the keycode input
    screen appears after the power is turned on.
    When it appears, enter the right keycode to
    start projection.
    Enter the same keycode in “Re-
    confirm”.
    System Lock––––
    5
    Locking the Operation
    Buttons on the Projector
    Use this function to lock the operation buttons
    on the projector.
    a Taking the Keylock offHold down ENTER on the projector for about 5
    seconds.
    On-screen display
    a Locking the Operation ButtonsHold down ENTER on the projector for about 5
    seconds while the projector is being turned on.
    On-screen display
    •The keylock function does not affect the opera-
    tion with the remote control buttons.
    •You cannot use the keylock function while the
    projector is warming up.
    •When the projector is in standby mode, you can
    release the keylock by holding down ENTER
    and STANDBY/ON on the projector simulta-
    neously for about 5 seconds.
    Keylock Function
    •Keylock cannot be set while the projector is:
    displaying the “Setup Guide” or “Menu”
    screens, in standby mode, warming up, chang-
    ing input signals, operating “Auto Sync” func-
    tion, in “FREEZE” mode or on the “System
    Lock” screen during warming up.
    Info
    Checking the Lamp Life
    Status
    You can confirm the cumulative lamp usage time
    and the remaining lamp life (percentage).
    Lamp usage condition
    Operated exclusively
    with Lamp Setting set to
    “Eco +Quiet”
    Operated exclusively
    with Lamp Setting set to
    “Bright”100%
    Approx.
    X,XXX
    hours
    Approx.
    X,XXX
    hours
    5%
    Approx.
    XXX hours
    Approx.
    XXX hours Remaining lamp life“Life”
    Note
    •It is recommended that the lamp be changed
    when the remaining lamp life becomes 5%.
    •The lamp life may vary depending on the us-
    age condition. 
    						
    							48
    Troubleshooting with the “Help” Menu
    Utilizing the “Help” Menu
    Functions
    This function advises you to solve the problems during usage.
    •You can adjust the items with check marks (✔).
    •The items in the “Help” menu change, de-
    pending on the input signal or setting that you
    have selected.
    •If the problem is not solved, refer to
    “Troubleshooting” (see pages 63 and 64).
    •When selecting “sRGB” in “Picture Mode”, the
    item “Color is faded or poor” is not displayed.
    This means you cannot change input signal
    types.
    Press O or Q to adjust. If the image is not improved, se-
    lect “Adjust horizontal noise”,
    then press ENTER. Select “Initiate “Auto Sync” Ad-
    justments”, then press ENTER.
    Press P or R to select “Vertical
    stripes or flickering image ap-
    pears” on Help menu, then press
    ENTER.
    Example: When image flickering appears
    Operation to solve image flickering when pro-
    jecting the computer RGB signal.
    34
    5
    6
    Note
    Press MENU/HELP.1
    2
    Press O or Q to select “Help”, then
    press ENTER.
    Adjustment buttons
    (P/R/O/Q) ENTER button
    MENU/HELP
    button
    0 PhaseSEL./ADJ. Rtn. Menu ENDHelp
    If there is no change after performing Auto Sync
    adjustments, adjust the following items.Initiate “Auto Sync” Adjustments. Vertical stripes or flickering image appear
    Adjust vertical noise
    Adjust horizontal noise
    Reset the 2 items above
    Return
    Signal Info 1024768
    H48.3  kHz  /  V   59.9  Hz
    SEL. ENTER END There is no picture or audio
    Vertical stripes or flickering image appear
    Data image is not centered
    Color is faded or poor
    Picture is dark
    The image is distorted
    Reset all adjustments to default settings
    SEL. ENTER END
    Picture SCR - ADJ PRJ - ADJHelp
    Help Vertical stripes or flickering image appear
    Press ENTER. 
    						
    							49
    Appendix
    Cleaning the lens■Use a commercially available blower or lens
    cleaning paper (for glasses and camera lenses)
    for cleaning the lens. Do not use any liquid type
    cleaning agents, as they may wear off the
    coating film on the surface of the lens.
    ■As the surface of the lens can easily get
    damaged, be careful not to scrape or hit the
    lens.
    Cleaning the exhaust and intake vents■Use a vacuum cleaner to clean dust from the
    exhaust vent and the intake vent.
    Cleaning the projector■Ensure that you have unplugged the power
    cord before cleaning the projector.
    ■The cabinet as well as the operation panel is
    made of plastic. Avoid using benzene or
    thinner, as these can damage the finish on the
    cabinet.
    ■Do not use volatile agents such as insecticides
    on the projector.
    Do not attach rubber or plastic items to the
    projector for long periods.
    The effects of some of the agents in the plastic
    may cause damage to the quality or finish of the
    projector.
    ■Wipe off dirt gently with a soft flannel cloth.
    ■When the dirt is hard to remove, soak a cloth in
    a mild detergent diluted with water, wring the
    cloth well and then wipe the projector.
    Strong cleaning detergents may discolor, warp
    or damage the coating on the projector. Make
    sure to test on a small, inconspicuous area on
    the projector before use.
    Maintenance
    •If you want to clean the air vents during projec-
    tor operation, ensure you press STANDBY/ON
    on the projector or STANDBY on the remote
    control and put the projector into standby
    mode. After the cooling fan has stopped, clean
    the vents.
    Info
    Wax
    Mild detergent
    Mild detergent diluted
    with water
    Thinner 
    						
    							50
    Maintenance Indicators
    About the lamp indicator
    ■When the remaining lamp life becomes 5% or less,  (yellow) and “Change The Lamp” will be
    displayed on the screen. When the percentage becomes 0%, it will change to  (red), the lamp will
    automatically turn off and then the projector will automatically enter standby mode. At this time, the
    lamp indicator will illuminate in red.
    ■If you try to turn on the projector a fourth time without replacing the lamp, the projector will
    not turn on.
    About the temperature warning indicator
    If the temperature inside the projector increases, due to blockage of the air vents, or the setting location,
    “” will illuminate in the lower left corner of the picture. If the temperature keeps on rising, the lamp
    will turn off and the temperature warning indicator will blink, the cooling fan will run, and then the projec-
    tor will enter standby mode. After “
    ” appears, ensure you perform the measures described on
    page 51.
    ■The warning lights (power indicator, lamp indicator and temperature warning indicator) on the
    projector indicate problems inside the projector.
    ■If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate
    red, and the projector will enter standby mode. After the projector has entered standby mode,
    follow the procedures given below.
    Red on
    Green on
    Red blinks
    Green blinks
    Green on
    Green blinks
    Red on
    Off
    Red on Power indicator
    Lamp indicator
    Temperature warning
    indicator
    Indicators on the Projector
    Normal (Standby)
    Normal (Power on)
    Abnormal (See page 51.)
    Normal (Cooling)
    Normal
    The lamp is warming up.
    The lamp is shut down abnormally or requires to be
    changed. (See page 51.)
    Normal
    The internal temperature is abnormally high. (See page 51.)
    Top View
    Lamp indicator Temperature warning
    indicator
    Power indicator 
    						
    							51
    Appendix
    •If the temperature warning indicator illuminates, and the projector enters standby mode, follow the
    possible solutions above and then wait until the projector has cooled down completely before plug-
    ging in the power cord and turning the power back on. (At least 10 minutes.)
    •If the power is turned off for a brief moment due to power outage or some other cause while using
    the projector, and the power supply recovers immediately after that, the lamp indicator will illumi-
    nate in red and the lamp may not be lit. In this case, unplug the power cord from the AC outlet,
    replace the power cord in the AC outlet and then turn the power on again.
    •The cooling fan keeps the internal temperature of the projector constant and this function is con-
    trolled automatically. The sound of the cooling fan may change during operation because the fan
    speed may change and this is not a malfunction.
    Maintenance indicator
    Problem
    The internal
    temperature is
    abnormally
    high.
    The lamp does
    not illuminate.
    Time to change
    the lamp.
    The lamp does
    not illuminate.
    The power
    indicator blinks
    in red when the
    projector is on.Cause
    •Blocked air intake
    •Cooling fan
    breakdown
    •Internal circuit
    failure
    •Clogged air intake
    •The lamp is shut
    down abnormally.
    •Remaining lamp life
    becomes 5% or
    less.
    •Burnt-out lamp
    •Lamp circuit failure
    •The lamp unit cover
    is open.Possible Solution
    •Relocate the projector to
    an area with proper
    ventilation. (See page 8.)
    •Take the projector to your
    nearest Sharp Authorized
    Projector Dealer or Service
    Center (see page 65) for
    repair.
    •Disconnect the power cord
    from the AC outlet, and
    then connect it again.
    •Carefully replace the lamp.
    (See page 52.)
    •Take the projector to your
    nearest Sharp Authorized
    Projector Dealer or Service
    Center (see page 65) for
    repair.
    •Please exercise care when
    replacing the lamp.
    •Securely install the cover.
    •If the power indicator blinks
    in red even when the lamp
    unit cover are securely
    installed, contact your
    nearest Sharp Authorized
    Projector Dealer or Service
    Center (see page 65) for
    advice.Abnormal
    Red on
    (Standby)
    Red on
    Red on
    (Standby)
    Red
    blinks
    Tempera-
    ture
    warning
    indicator
    Lamp
    indicator
    Power
    indicatorNormal
    Off
    Green on
    (Green
    blinks
    when the
    lamp is
    warming
    up or
    turning
    off.)
    Green on/
    Red on
    Green
    blinks
    (Cooling)
    Info 
    						
    							52
    Regarding the Lamp
    Lamp■It is recommended that the lamp (sold separately) be replaced when the remaining lamp life becomes
    5% or less, or when you notice a significant deterioration in the picture and color quality. The lamp life
    (percentage) can be checked with the on-screen display. (See page 47.)
    ■Purchase a replacement lamp of type AN-F212LP from your place of purchase, nearest Sharp
    Authorized Projector Dealer or Service Center.
    Caution Concerning the Lamp■This projector utilizes a pressurized mercury lamp. A loud sound may indicate lamp failure. Lamp
    failure can be attributed to numerous sources such as: excessive shock, improper cooling, surface
    scratches or deterioration of the lamp due to a lapse of usage time.
    The period of time up to failure largely varies depending on the individual lamp and/or the condition
    and the frequency of use. It is important to note that failure can often result in the bulb cracking.
    ■When the lamp replacement indicator and on-screen display icon are illuminated, it is recommended
    that the lamp be replaced with a new one immediately, even if the lamp appears to be operating
    normally.
    ■Should the lamp break, there is also a possibility that glass particles may spread inside of the
    projector. In such a case, it is recommended you contact your nearest Sharp Authorized Projector
    Dealer or Service Center to assure safe operation.
    ■Should the lamp break, the glass particles may spread inside the lamp cage or gas contained in the
    lamp may be vented into the room from the exhaust vent. Because the gas in this lamp includes
    mercury, ventilate the room well if the lamp breaks and avoid all exposure to the released gas. In case
    of exposure to the gas, consult a doctor as soon as possible.
    Replacing the Lamp
    Caution
    •Do not remove the lamp unit from the projector right after use. The lamp will be very hot and may
    cause burns or injury.
    •Wait at least one hour after the power cord is disconnected to allow the surface of the lamp unit to fully
    cool before removing the lamp unit.
    ■Carefully change the lamp by following the instructions described in this section. * If you wish,
    you may have the lamp replaced at your nearest Sharp Authorized Projector Dealer or Service
    Center.
    *If the new lamp does not light after replacement, take your projector to the nearest Sharp Authorized
    Projector Dealer or Service Center for repair.
    IMPORTANT NOTE TO U.S. CUSTOMERS:
    The lamp included with this projector is backed by a 90-day parts and labor limited
    warranty. All service of this projector under warranty, including lamp replacement,
    must be obtained through a Sharp Authorized Projector Dealer or Service Center.
    For the name of the nearest Sharp Authorized Projector Dealer or Service Center,
    please call toll-free: 1-888-GO-SHARP (1-888-467-4277).
    Hg LAMP CONTAINS MERCURY For State Lamp Disposal
    Information
    www.lamprecycle.org or 1-800-BE-SHARP
    U.S.A. ONLY 
    						
    							53
    Appendix
    Removing and Installing
    the Lamp Unit
    •Do not touch the glass surface of the lamp
    unit or the inside of the projector.
    •To avoid injury to yourself and damage to the
    lamp, make sure you carefully follow the steps
    below.
    •Do not loosen other screws except for the
    lamp unit cover and lamp unit.
    Press STANDBY/ON on the projec-
    tor or STANDBY on the remote
    control to put the projector into
    standby mode.
    •Wait until the cooling fan stops.
     Warning!
    •Do not remove the lamp unit from the projec-
    tor right after use. The lamp and parts around
    the lamp will be very hot and may cause burns
    or injury.
    Disconnect the power cord.•Unplug the power cord from the AC
    socket.
    •Leave the lamp until it has fully cooled
    down (about 1 hour).
    Remove the lamp unit cover.•Turn the projector over. Loosen the user
    service screw (1) that secures the lamp
    unit cover. Remove the lamp unit cover
    (2).
    Lamp unit
    AN-F212LP
    Info
    Optional
    accessory
    AC socket
    User service screw
    (for lamp unit cover)1
    2
    3
    STANDBY/ON button
    1
    2 
    						
    							54
    Remove the lamp unit.•Loosen the securing screws from the
    lamp unit. Hold the lamp unit and pull it
    in the direction of the arrow. At this time,
    keep the lamp unit horizontal and do not
    tilt it.
    Resetting the Lamp Timer
    Reset the lamp timer after replacing the lamp.
    Insert the new lamp unit.•Press the lamp unit firmly into the lamp
    unit compartment. Fasten the securing
    screws.
    Replace the lamp unit cover.•Align the tab on the lamp unit cover
    (1) and place it while pressing the tab
    (2) to close it. Then tighten the user ser-
    vice screw (3) to secure the lamp unit
    cover.
    4
    5
    6
    Connect the power cord.•Plug the power cord into the AC socket
    of the projector.
    Reset the lamp timer.•While simultaneously holding down
    MENU/HELP, ENTER and R on the pro-
    jector, press STANDBY/ON on the pro-
    jector.
    •“LAMP 0000H” is displayed, indicating
    that the lamp timer is reset. •Make sure to reset the lamp timer only when
    replacing the lamp. If you reset the lamp timer
    and continue to use the same lamp, this may
    cause the lamp to become damaged or ex-
    plode.
    1
    2
    Info
    AC socket
    •If the lamp unit and lamp unit cover are
    not correctly installed, the power will not
    turn on, even if the power cord is con-
    nected to the projector.
    Info
    Regarding the Lamp (Continued)
    Securing screws
    ENTER button
    MENU/HELP
    buttonR button STANDBY/ON
    button 
    						
    							55
    Appendix
    COMPUTER/COMPONENT input and COMPUTER/COMPONENT output Terminals : mini D-
    sub 15 pin female connector
    COMPUTER Input/Output
    Pin No. Signal
      1. Video input (red)
      2. Video input (green/sync on green)
      3. Video input (blue)
      4. Not connected
      5. Not connected
      6. Earth (red)
      7. Earth (green/sync on green)
      8. Earth (blue)
      9. Not connected
    10. GND
    11. Not connected
    12. Bi-directional data
    13. Horizontal sync signal: TTL level
    14. Vertical sync signal: TTL level
    15. Data clockCOMPONENT Input/Output
    Pin No. Signal
      1. PR (CR)
      2. Y
      3. PB (CB)
      4. Not connected
      5. Not connected
      6. Earth (PR)
      7. Earth (Y)
      8. Earth (PB)
      9. Not connected
    10. Not connected
    11. Not connected
    12. Not connected
    13. Not connected
    14. Not connected
    15. Not connected
    510 15
    1
    11
    6
    DVI-D Terminal  : 24 pin connector (XR-32X only)
    Pin No. SignalPin No. Signal
      1. T.M.D.S data 2–16. Hot plug detection
      2. T.M.D.S data 2+17. T.M.D.S data 0–
      3. T.M.D.S data 2 shield18. T.M.D.S data 0+
      4. Not connected19. T.M.D.S data 0 shield
      5. Not connected20. Not connected
      6. DDC clock21. Not connected
      7. DDC data22. T.M.D.S clock shield
      8. Not connected23. T.M.D.S clock+
      9. T.M.D.S data 1–24. T.M.D.S clock–
    10. T.M.D.S data 1+
    11. T.M.D.S data 1 shield
    12. Not connected
    13. Not connected
    14. +5V power
    15. Ground17 24
    1
    9
    168
    Connecting Pin Assignments 
    						
    							56
    RS-232C Terminal  : mini DIN 9 pin female connector
    RD
    SD
    SG
    RS
    CS Signal Name
    8
    9
    6
    5
    2143 7Pin No.
    1.
    2.
    3.
    4.
    5.
    6.
    7.
    8.
    9.I/O Reference
    Not connected
    Connected to internal circuit
    Connected to internal circuit
    Not connected
    Connected to internal circuit
    Not connected
    Connected to CS in internal circuit
    Connected to RS in internal circuit
    Not connected Receive Data
    Send Data
    Signal Ground
    Request to Send
    Clear to SendInput
    Output
    RS-232C Terminal  : D-sub 9 pin male connector of the DIN-D-sub RS-232C adaptor
    RD
    SD
    SG
    RS
    CS Signal Name Pin No.
    1.
    2.
    3.
    4.
    5.
    6.
    7.
    8.
    9.I/O Reference
    Not connected
    Connected to internal circuit
    Connected to internal circuit
    Not connected
    Connected to internal circuit
    Not connected
    Connected to CS in internal circuit
    Connected to RS in internal circuit
    Not connected Receive Data
    Send Data
    Signal Ground
    Request to Send
    Clear to SendInput
    Output
    CD
    RD
    SD
    ER
    SG
    DR
    RS
    CS
    CI Signal Pin No.
    1.
    2.
    3.
    4.
    5.
    6.
    7.
    8.
    9.
    RS-232C Cable recommended connection : D-sub 9 pin female connector
    CD
    RD
    SD
    ER
    SG
    DR
    RS
    CS
    CI Signal Pin No.
    1.
    2.
    3.
    4.
    5.
    6.
    7.
    8.
    9.51
    96
    USB Terminal  : Type B USB connector
    VCC
    USB–
    USB+
    SG Signal Name Pin No.
    1.
    2.
    3.
    4.USB power
    USB data–
    USB data+
    Signal Ground
    15
    69
    12 43
    Projector
    Pin No.
    4
    5
    6Computer
    Pin No.
    4
    5
    6
    •Depending on the controlling device used, it may be necessary to connect Pin 4 and Pin 6 on the
    controlling device (e.g. computer).
    Note
    Connecting Pin Assignments (Continued) 
    						