    Useful Features
    This function allows you to select the input signal type
    (COMPUTER/RGB or COMPONENT) for INPUT 1 port.
    (Slide the MOUSE/ADJUSTMENT switch
    on the remote control to the ADJ. position.)
    1Press MENU.
    2Press ß/© to select “Options”.
    3Press ∂/ƒ to select “Signal Type”, and then
    press©.
    4Press ∂/ƒ to select “Computer/RGB” or
    “Component”.
    5Press ENTER to save the setting.
    6To exit from the GUI, press MENU.
    Selecting the Signal Type
    MOUSEADJ.
    5 2, 3, 4 1, 6
    Projector
    (GUI) On-screen Display
    (Slide the MOUSE/ADJUSTMENT switch
    on the remote control to the ADJ. position.)
    1Press MENU.
    2Press ß/© to select “Options”.
    3Press ∂/ƒ to select “Signal Info” to display the
    current input signal.
    4To exit from the GUI, press MENU.
    • In VIDEO mode, the resolution and frequency settings will
    not be displayed.
    This function allows you to check the current input signal
    information.
    2, 3 1, 4
    Projector
    Checking the Input Signal
    (GUI) On-screen Display
    MOUSEADJ.
    Remote control
    Remote control   
    						
    							E-41
    Useful Features
    (GUI) On-screen Display
    Setting a Background Image
    This function allows you to select the image displayed
    when no signal is being sent to the projector.
    Description of Background Images
    (Slide the MOUSE/ADJUSTMENT switch
    on the remote control to the ADJ. position.)
    1Press MENU.
    2Press ß/© to select “Options”.
    3Press ∂/ƒ to select “Background”, and then press
    ©.
    4Press ∂/ƒ to select the background image you want
    to display on the screen.
    5Press ENTER to save the setting.
    6To exit from the GUI, press MENU.
    •By selecting “Custom”, the projector can display a custom
    image (i.e. your company logo) as the background image.
    Custom image must be 256-color BMP file with a picture
    size of 1,024  768 or lower. Please see the Sharp
    Advanced Presentation Software operation manual for how
    to save (or change) a custom image.
    Selected item
    Sharp
    Custom
    Blue
    NoneBackground image
    SHARP default image
    User customized image (i.e. company logo)
    Blue screen
    Black screen
    5 2, 3, 4 1, 6
    Projector
    MOUSEADJ.
    Remote control  
    						
    							E-42
    Useful Features
    •This function allows you to specify the image to be
    displayed upon the projector’s startup.
    •A custom image (i.e. your company logo) can be
    loaded on the projector via IrCOM or an RS-232C
    cable. See pages 14 and 25 in this operation manual,
    and also the supplied Sharp Advanced Presentation
    Software operation manual for detailed instructions.
    Description of Startup Images
    (Slide the MOUSE/ADJUSTMENT switch
    on the remote control to the ADJ. position.)
    1Press MENU.
    2Press ß/© to select “Options”.
    3Press ∂/ƒ to select “Startup Image”, and then press
    ©.
    4Press ∂/ƒ to select the startup image you want to
    display on the screen.
    5Press ENTER to save the setting.
    6To exit from the GUI, press MENU.
    •By selecting “Custom”, the projector can display a custom
    image (i.e. your company logo) as the startup image.
    Custom image must be 256-color BMP file with a picture
    size of 1,024  768 or lower. Please see the Sharp
    Advanced Presentation Software operation manual for how
    to save (or change) a custom image.
    Selected item
    Sharp
    Custom
    NoneStartup image
    SHARP default image
    User customized image (i.e. company logo)
    Black screen5 2, 3, 4 1, 6
    Projector
    (GUI) On-screen Display
    MOUSEADJ.
    Remote control
    Selecting a Startup Image  
    						
    							E-43
    Useful Features
    Reverse/Invert Image Function
    This projector is equipped with a reverse/invert image
    function which allows you to reverse or invert the pro-
    jected image for various applications.
    Description of Projected Images
    (GUI) On-screen Display
    Selected item
    Front
    CeilingFront
    Rear
    CeilingRearProjected image
    Normal image
    Inverted image
    Reversed image
    Reversed and inverted image
    (Slide the MOUSE/ADJUSTMENT switch
    on the remote control to the ADJ. position.)
    1Press MENU.
    2Press ß/©  to select “PRJ Mode”.
    3Press ∂/ƒ to select the desired projection mode.
    4Press ENTER to save the setting.
    5To exit from the GUI, press MENU. Projector
    When Selecting “Front”
    When Selecting “CeilingFront”
    When Selecting “Rear”
    When Selecting “CeilingRear”
    MOUSEADJ.
    •This function is used for the reversed image and ceiling-
    mount setups. See page 20 for these setups.
    Remote control
    4 2, 3 1, 5     
    						
    							E-44
    Useful Features
    Using the Presentation Tools
    Red Green Blue Yellow Orange White Black
    When selecting Sharp default image
    Menu Window
    1
    3 2, 4
    This projector is equipped with presentation tools. These
    will help you emphasize keypoints within your
    presentation.
    (Slide the MOUSE/ADJUSTMENT switch
    on the remote control to the ADJ. position.)
    1Press TOOLS to display the presentation tools
    menu window on the screen.
    2Press ∂/ƒ/ß/© to select the desired tool and
    color.
    3Press ENTER to select it.
    4Once the tool is displayed on the screen, press
    ∂/ƒ/ß/© to move it around the screen.
    5Press ENTER to stamp the tool on the screen.
    6Use UNDO to individually delete tools stamped
    on the screen.
    •You can stamp each tool as many times as you want on the
    screen.
    •To clear all the stamped presentation tools on the screen,
    press ∂/ƒ/ß/© to select “
    ” and ENTER.
    MOUSEADJ.
    Displaying the break time
    (Slide the MOUSE/ADJUSTMENT switch
    on the remote control to the ADJ. position.)
    1Press TOOLS to display the presentation tools
    menu window on the screen.
    2Press ∂/ƒ/ß/© to select “
    ” in the menu
    window.
    3Press ENTER to start counting down the break
    time.
    4Press ∂ to increase or ƒ to decrease the break
    time.
    •The break time is displayed against the background image
    selected in “Selecting a Startup Image”. (See page 42.)
    MOUSEADJ.
    16
    3, 5 2, 4
    On-screen DisplayProjector
    ProjectorRemote control
    Remote control   
    						
    							E-45
    Useful Features
    Status Function
    This function can be used to display all the adjusted
    settings on the screen simultaneously.
    (Slide the MOUSE/ADJUSTMENT switch
    on the remote control to the ADJ. position.)
    1Press MENU.
    2Press ß/© to select “Status”.
    3Press ENTER to display all the adjusted settings.
    4To exit from the GUI, press MENU.
    3 2 1, 4
    Projector
    (GUI) On-screen Display
    MOUSEADJ.
    2
    3Remote control   
    						
    							E-46
    Maintenance &
    Troubleshooting
    Maintenance &
    Troubleshooting 
    						
    							E-47
    Maintenance &
    Troubleshooting
    Problem
    •Blocked air intake.
    •Cooling fan breakdown.
    •Internal circuit failure.
    •Burnt-out lamp.
    •Lamp circuit failure.
    Lamp/Maintenance Indicators
    Maintenance Indicator
    The internal
    temperature is
    abnormally high.
    The lamp does
    not light up. TEMPERATURE
    WARNING indicator
    LAMP REPLACE-
    MENT indicatorCondition Possible Solution
    •Relocate the projector to an area with
    proper ventilation.
    •Take the projector to your nearest
    Authorized Sharp Industrial LCD Products
    Dealer or Service Center for repair.
    •Carefully replace the lamp. (See pages 48
    and 49.)
    •Take the projector to your nearest
    Authorized Sharp Industrial LCD Products
    Dealer or Service Center for repair.
    Maintenance Indicators
    •The warning lights on the projector indicate problems
    inside the projector.
    •There are two warning lights: a TEMPERATURE
    WARNING indicator which warns that the projector is
    too hot, and a LAMP REPLACEMENT indicator which
    lets you know when to change the lamp.
    •If a problem occurs, either the TEMPERATURE
    WARNING indicator or the LAMP REPLACEMENT
    indicator will light up red. After turning off the power,
    follow the procedures given below.
    TEMPERATURE
    WARNING
    indicator LAMP
    REPLACEMENT
    indicator
    •If the TEMPERATURE WARNING indicator lights up, follow the above possible solutions and then wait until the projector has
    cooled down completely before turning the power back on. (At least 5 minutes.)
    •If the power is turned off and then turned on again, as during a brief rest, the LAMP REPLACEMENT indicator may be
    triggered, preventing the power from going on. Should this occur, take the power cord out of the wall outlet and put it back
    in again.
    Lamp
    The lamp in this projector operates for approximately 1,500 cumulative hours, depending on the usage environ-
    ment. It is recommended that the lamp be replaced after 1,400 cumulative hours of use or when you notice a
    significant deterioration of the picture and color quality. The lamp usage time can be checked with the On-screen
    Display (see page 39).
    CAUTION
    •Intense light hazard. Do not attempt to look into the aperture and lens while the projector is operating.
    •As the usage environment can vary significantly, the projector lamp may not operate for 1,500 hours. 
    						
    							E-48
    Maintenance &
    Troubleshooting
    Replacing the Projection Lamp
    46Remove the lamp
    cage.5Replace the lamp cage
    (after changing the lamp).
    13Turn off the power.2Disconnect the power
    cord.
    Unplug the power cord from the
    AC socket.
    Slide the lamp cage
    cover out.
    Slide the lamp cage
    cover in.
    Slide the lamp cage cover in the
    direction of the arrow. Then
    fasten the user service screw. Remove the securing screws
    from the lamp cage. Hold the
    lamp cage by the handle and
    pull it towards you.
    Turn over the projector and un-
    fasten the user service screw
    that secures the lamp cage
    cover. Then slide the cover in the
    direction of the arrow.Press POWER OFF. Wait until
    the cooling fan stops.
    Press the lamp cage firmly into
    the lamp cage compartment.
    Fasten the securing screws.
    It is recommended that the lamp be replaced after approximately 1,500 cumulative hours of use or when you
    notice a significant deterioration of the picture and color quality. Carefully change the lamp by following the steps
    below.
    If the new lamp does not light after replacement, take your projector to the nearest Authorized Sharp Industrial
    LCD Products Dealer or Service Center for repair. Purchase a replacement lamp unit (lamp/cage module) of the
    current type BQC-XGNV7XU/1 from your nearest Authorized Sharp Industrial LCD Products Dealer or Service
    Center. Then carefully change the lamp by following the instructions below. If you wish, you may have the lamp
    replaced at your nearest Authorized Sharp Industrial LCD Products Dealer or Service Center.
    IMPORTANT NOTE TO U.S. CUSTOMERS:
    The lamp included with this projector is backed by a 90-day parts and labor limited warranty. All service of this
    projector under warranty, including lamp replacement, must be obtained through an Authorized Sharp Industrial LCD
    Products Dealer or Service Center. For the name of the nearest Authorized Sharp Industrial LCD Products Dealer or
    Service Center, please call toll-free: 1-800-BE-SHARP (1-800-237-4277).   
                                                                  U.S.A. ONLY
    Removing and installing the lamp unit
    CAUTION
    •Do not remove the lamp cage directly after operation of the projector. The lamp may be extremely hot. Wait at least one
    hour after the power cord is disconnected to allow the surface of the lamp cage to fully cool before removing the lamp
    cage.
    •Be sure to remove the lamp cage by the handle. Be sure not to touch the glass surface of the lamp cage or the inside of
    the projector.
    •To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below.
    User service screw
    or
    User service screw
    Securing
    screwSecuring
    screw 
    						
    							E-49
    Maintenance &
    Troubleshooting
    Replacing the Projection Lamp
    1Connect the power
    cord.Reset the lamp timer.
    While pressing ƒ, © and
    ENTER on the projector, press
    POWER ON on the projector. Plug the power cord into the AC
    socket of the projector.
    Resetting the lamp timer
    Using the Kensington Lock
    This projector has a Kensington Security Standard
    connector for use with a Kensington MicroSaver Security
    System. Refer to the information that came with the
    system for instructions on how to use it to secure the
    projector.
    •Reset the lamp timer only after replacing the lamp.
    Problem
    No picture and no sound.
    Sound is heard but no picture
    appears.
    Color is faded or poor.
    Picture is blurred.
    Picture appears but no sound is
    heard.
    An unusual sound is occasionally
    heard from the cabinet.
    Maintenance indicator lights up.
    Data cannot be received via
    IrCOM.
    Picture noise appears.
    480P images do not appear.
    Color is distorted (except for
    VIDEO mode).
    Lens comes off.
    Troubleshooting
    “LAMP 0000H” is displayed,
    indicating that the lamp timer is
    reset.
    2
    Check
    •Projector power cord is not plugged into the wall outlet.
    •Selected input is wrong. (See page 17.)
    •Cables improperly connected to side panel of the projector. (See pages 11–15.)
    •Remote control batteries have run down. (See page 8.)
    •Remote control’s MOUSE/ADJUSTMENT switch is set to MOUSE.
    •Cables improperly connected to side panel of the projector. (See pages 11–15.)
    •“Contrast” and “Bright” adjustments are set to minimum position. (See page 27.)
    •On-screen Display (“BLACK SCREEN”) is turned off and Black Screen function is turned on,
    creating a black image. (See page 37.)
    •“Color” and “Tint” adjustments are not correct. (See page 27.)
    •Adjust the focus. (See page 17.)
    •Projection distance is too long or too short to allow for proper focus. (See page 18.)
    •Cables improperly connected to side panel of the projector. (See pages 11–15.)
    •Volume is set to minimum. (See page 17.)
    •If the picture is normal, the sound is due to cabinet shrinkage caused by temperature changes.
    This will not affect operation or performance.
    •Refer to “Lamp/Maintenance Indicators” on page 47.
    •Distance and angle between the projector and transmitting device are out of the designated range.
    (See page 25.)
    •Refer to the operation manual of the transmitting device.
    •Refer to the section “Troubleshooting” in the operation manual of the supplied software.
    •Adjust the phase setting. (See page 29.)
    •Noise may appear when used with certain computers. Set the NOISE FILTER to ON using the RS-
    232C command. (See pages 53 and 54.)
    •Set the resolution mode to 480P. (See page 32.)
    •Change the input signal type. (See page 40.)