Sharp Mx 2310u Owners Manual
Have a look at the manual Sharp Mx 2310u Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 615 Sharp manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
MX-3610N ADJUSTMENTS AND SETTINGS 4 – 5 2) Close the front cabinet. 3) Select a developing unit to be adjusted. 4) When [EXECUTE] key is press ed, it is highlighted. The DV roller rotates, and the toner density sensor detects toner den- sity, and the output value is displayed. The above operation is executed for 1.5 minutes, and the aver- age value of the toner density sensor detection level is set (saved) as the reference toner density control value. When the reference toner density control adjustment operation is completed, [EXECUTE] key returns to normal from highlight. This makes known about whether the adjustment operation is completed or not. The above operation is executed each of the lower speed mode and the middle speed mode, and the reference toner density control value is set for each of them. If the operation is interrupted within 1.5 minutes, the adjust- ment result is not reflected. When [EXECUTE] key is pressed during the operation, the operation is stopped and [EXECUTE] key returns to the normal display. If [EE-EU], [EE-EL], or [EE-EC] is displayed, setting of the ref- erence toner density control value is not completed normally. Troubleshoot the cause, remove the cause, and perform set- ting again. 5) Cancel SIM 25-2. 6) Confirm that Install the toner cartridge is displayed, and install the toner cartridge by the following procedures. 7) Shake the toner cartridge horizontally several times. 8) Open the front cabinet, and insert each toner cartridge. Be sure to install the color cartridges to their proper positions. Avoid installation to a different color position. Do not forcibly insert the toner cartridge. Push it in until the cartridge is securely locked in place. Developing units removed, be sure to remove the toner car- tridges as well to prevent toner clogging. Color toner cartridge positions 9) Close the front cabinet. 10) Confirm that Toner replenishment in progress is displayed, and wait until the display disappears. (It takes 30 sec - 6 min.) This procedure is for checking the toner supply operation from the toner cartridge to the DV unit. The operation time differs depending on the toner quantity in the toner cartridge, uneven distribution of toner, and the internal state of the toner car- tridge. Do not perform operations which interrupt the above operation, such as opening the front cover, entering the SIM mode, and turning OFF/ON the power. If this precaution is ignored, Trou- ble codes F2-40 - 43 or F2-64 - 67 or a over-toned condition may occur. When replacing developer, always r eplace all the three colors of Yellow, Magenta, and Cyan. If only one color is replaced, color balance may be adversely affected. Black developer can be replaced individually. When developer is replaced, be sure to perform the color balance adjustment. When not replacing the developer, do not execute SIM25-2. Error display Error name Detail of error EE-EL EL abnormality Sensor output level less than 1.0V, or control voltage over 8.0V. EE-EU EU abnormality Sensor output level over 2.3V, or control voltage less than 2.0V. EE-EC EC abnormality Sensor output level: other than 1.65 0.13V YMCBK
MX-3610N ADJUSTMENTS AND SETTINGS 4 – 6 ADJ 2Adjusting high voltage values 2-AAdjust the main charger grid voltage This adjustment must be performed in the following cases: * When the MC/DV high voltage power PWB is replaced. * U2 trouble has occurred. * The PCU PWB has been replaced. * The EEPROM of the PCU PWB has been replaced. 1) Enter the SIM 8-2 mode. 2) Select an output mode and an item to be adjusted. 3) Enter the adjustment value (s pecified value) in the middle speed mode, and press [OK] key. Enter the adjustment value of each mode which is specified on the label attached on the MC/DV high voltage power PWB. When [EXECUTE] key is pressed, the voltage entered in the procedure 3) is outputted for 30sec and the set value is saved. When [EXECUTE] key is pressed again, the output is stopped. Note that the adjustment value may differ depending on the MC/DV high voltage power PWB. Since the adjustment value label is attached on the MC/DV high voltage PWB, the PWB must be removed in order to check the adjustment value. This is a troublesome procedure. T herefore, it is advisable to put down the adjustment value in advance. When the adjustment value (specified value) of the middle speed mode is set, the adjustment values of the other modes are auto- matically set according to the middle speed mode setting in a cer- tain relationship. Since the high voltage output cannot be checked with a digital multi meter in this model, a judgment of the output must be made by checking the print image quality. EXECUTE EXECUTE or after 30 sec.
MX-3610N ADJUSTMENTS AND SETTINGS 4 – 7 2-BAdjust the developing bias voltage This adjustment must be performed in the following cases: * When the MC/DV high voltage power PWB is replaced. * U2 trouble has occurred. * The PCU PWB has been replaced. * The EEPROM of the PCU PWB has been replaced. 1) Enter the SIM 8-1 mode. 2) Select an output mode and an item to be adjusted. 3) Enter the adjustment value (s pecified value) in the middle speed mode, and press [OK] key. Enter the adjustment value of each mode which is specified on the label attached on the MC/DV high voltage power PWB. When [EXECUTE] key is pressed, the voltage entered in the procedure 3) is outputted for 30s ec and the set value is saved. When [EXECUTE] key is pressed again, the output is stopped. Note that the adjustment value may differ depending on the MC/DV high voltage power PWB. Since the adjustment value label is attached on the MC/DV high voltage PWB, the PWB must be removed in order to check the adjustment value. This is a troublesome procedure. T herefore, it is advisable to put down the adjustment value in advance. When the adjustment value (specified value) of the middle speed mode is set, the adjustment values of the other modes are auto- matically set according to the middle speed mode setting in a cer- tain relationship. Since the high voltage output cannot be checked with a digital multi meter in this model, a judgment of the output must be made by checking the print image quality. Item/Display (Mode) Content Adjustment range Actual voltage MIDDLE A MIDDLE SPEED DVB_KDeveloping bias voltage (Middle speed mode) K 0 - 600 –450V 5V B MIDDLE SPEED DVB_C Developing bias voltage (Middle speed mode) C 0 - 600 –450V 5V C MIDDLE SPEED DVB_M Developing bias voltage (Middle speed mode) M 0 - 600 –450V 5V D MIDDLE SPEED DVB_Y Developing bias voltage (Middle speed mode) Y 0 - 600 –450V 5V EXECUTE EXECUTE
MX-3610N ADJUSTMENTS AND SETTINGS 4 – 8 2-CTransfer current and voltage adjustment This adjustment must be performed in the following cases: * When the TC high voltage PWB is replaced. * U2 trouble has occurred. * The PCU PWB has been replaced. * The EEPROM of the PCU PWB has been replaced. 1) Enter the SIM 8-6 mode. 2) Select an item to be adjusted. EXECUTE EXECUTE
MX-3610N ADJUSTMENTS AND SETTINGS 4 – 9 3) Enter the adjustment value (specified value), and press [OK] key. When [EXECUTE] key is pressed, the voltage entered in the pr ocedure 3) is outputted for 30sec and the set value is saved. When [EXECUTE] key is pressed again, the output is stopped. By setting the default value (specified value), the specified output is provided. K TC2 PLAIN CL SPX Secondary transfer bias adjustment valueColor Standard paperFront surface 51 - 255 96 –35 A 103 –40 A 110 –45 A L TC2 PLAIN CL DPX Back surface 51 - 255 76 –20A90–30 A 96 –35 A M TC2 PLAIN BW SPX Black/WhiteFront surface 51 - 255 96 –35 A 103 –40 A 110 –45 A N TC2 PLAIN BW DPX Back surface 51 - 255 76 –20A90–30 A 96 –35 A O TC2 HEAVY1 CL SPX Color Heavy paper 1Front surface 51 - 255 83 –25 A83–25 A 83 –25 A P TC2 HEAVY1 CL DPX Back surface 51 - 255 76 –20A76–20 A 76 –20 A Q TC2 HEAVY1 BW SPX Black/WhiteFront surface 51 - 255 69 –15 A69–15 A 69 –15 A R TC2 HEAVY1 BW DPX Back surface 51 - 255 69 –15A69–15 A 69 –15 A S TC2 HEAVY2 CL Color Heavy paper 2 51 - 255 83 –25 A83–25 A 83 –25 A T TC2 HEAVY2 BW Black/White51 - 255 69 –15A69–15 A 69 –15 A U TC2 OHP CL ColorOHP51 - 255 69 –15 A69–15 A 69 –15 A V TC2 OHP BW Black/White51 - 255 69 –15A69–15 A 69 –15 A W TC2 ENVELOPE CL ColorEnvelope 51 - 255 69 –15 A69–15 A 69 –15 A X TC2 ENVELOPE BW Black/White51 - 255 69 –15A69–15 A 69 –15 A Y TC2 THIN CL ColorThin paper 51 - 255 96 –35 A 103 –40 A 110 –45 A Z TC2 THIN BW Black/White51 - 255 96 –35A 103 –40 A 110 –45 A AA TC2 GLOSSY CL ColorGloss paper 51 - 255 83 –25 A83–25 A 83 –25 A AB TC2 GLOSSY BW Black/White51 - 255 69 –15A69–15 A 69 –15 A AC TC2 CLEANING Secondary transfer cleaning bias adjustment valueCleaning process (negative pole) 51 - 255 59 –8 A59–8 A59–8 A AD TC2 CLEAN LOW SPD Low speed print mode0 - 255 26 0V 26 0V 26 0V AE TC2 CLEAN MIDDLE SPD Middle speed print mode 0 - 255 26 0V 26 0V 26 0V AF TC2 CLEAN CLEANING Cleaning bias (positive pole) 0 - 255 102 500V 102 500V 102 500V AG PTC LOW SPEED CL PTC current adjustment valueColor Low speed 51 - 255 73 –200 A 73 –200A 73 –200 A AH PTC MIDDLE SPEED CL Middle speed 51 - 255 73 –200 A 73 –200 A 73 –200 A AI PTC LOW SPEED BW Black/White Low speed 51 - 255 73 –200 A 73 –200A 73 –200 A AJ PTC MIDDLE SPEED BW Middle speed 51 - 255 73 –200 A 73 –200 A 73 –200 A AK CASE VOLT LOW CL PTC voltage adjustment valueColor Low speed 0 - 255 0 0V 0 0V 0 0V AL CASE VOLT MID CL Middle speed 0 - 255 0 0V 0 0V 0 0V AM CASE VOLT LOW BW Black/White Low speed 0 - 255 0 0V 0 0V 0 0V AN CASE VOLT MID BW Middle speed 0 - 255 0 0V 0 0V 0 0V Item/Display ContentSetting range 18cpm/20cpm/ 23cpm machine 26cpm/31cpm machine 36cpm machine Default value Actual output value Defaul t value Actual output value Default value Actual output value
MX-3610N ADJUSTMENTS AND SETTINGS 4 – 10 ADJ 3Image density sensor adjustment Before executing this adjustment, check to confirm the following items. * Check to confirm that the colo r image density sensor (image reg- istration sensor F) and the bl ack image density sensor (image registration sensor R) are clean. * Check to confirm that the image density sensor calibration plate is clean. * Check to confirm that the tr ansfer belt is clean and free from scratches. 3-A Image density sensor calibration There are some parts variations in the image density sensor sec- tion. Therefore, the absolute image density detection level differs in each machine. To correct this, calibration is executed. This adjustment must be performed in the following cases: * When the color image density sens or (image registration sensor F) is replaced. * When the image registration sensor unit is replace. * U2 trouble has occurred. * The PCU PWB has been replaced. * The EEPROM of the PCU PWB has been replaced. * The image density sensor and the standard reflection plate are cleaned. Perform the color image density sensor (image registration sensor F) calibration in one of the following methods. Method 1 Color image density sensor (Image r egistration sensor F) calibra- tion (SIM44-61) When the image density sensor unit is replaced, perform the adjustment by this procedure. When the registration sensor unit is replaced, the calibration value is set manually with this method. The calibration jig is not required. Method 2 Color image density sensor (Image r egistration sensor F) calibra- tion (SIM44-13) When the color image density sens or (image registration sensor F) is solely replaced, be sure to perfo rm the adjustment by this proce- dure. A calibration jig is required for this procedure. The adjustment by this method must be performed in the following cases: • The SIM44-2 PCS_CL LED ADJ value is increased by aging and dirt of the image density sensor and the standard reflection plate. • When the density of an output image is decreased and the differ- ence between the SIM44-2 PCS_CL LED ADJ value and the SIM44-13 PCS_CL LED ADJ value is 30 or more, the image den- sity sensor, the registration s ensor, and the standard reflection plate may be dirtied. In this case, clean the image dens ity sensor, the registration sen- sor, and the standard reflection plate with dry cloth, and perform calibration with SIM44-13 by using the calibration tool (UKOG- 0318FCZZ). a. Procedure by calibration (SIM44-61) of the color image density sensor (image registration sensor F) 1) Enter the SIM44-61 mode. 2) Select an adjustment item. 3) Enter the adjustment value with 10 key. As the adjustment value, enter the value on the label attached to the slot section of the toner cartridge (BK) of the sensor unit. 4) Press [OK] key. Item/Display ContentSetting range Default value A PCS_CL CARB OUT Calibration plate sensor value 1 - 255 108 B PCS_CL LED ADJ Color sensor light emitting quantity adjustment value 1 - 255 21
MX-3610N ADJUSTMENTS AND SETTINGS 4 – 11 b. Color image density sensor (Image registration sensor F) calibration (Method by SIM44-13) 1) Enter the SIM44-13 mode. 2) Open the front cover, and remove the waste toner box. Check to confirm that the belt tensi on of the primary transfer unit is released (the separation lever of the primary transfer unit is as shown in the figure). If the belt tension is not released, turn the separation lever to the state shown in the figure. When the transfer belt tension of the primary transfer unit is released manually, turn on the power again after completion of the work. This procedure initializes the transfer roller to return it to the home position. 3) Open the right paper transport unit, and remove the BK devel- oping unit, the BK OPC drum unit, and the primary transfer unit. 4) Install the color image density sensor (image registration sen- sor F) calibration jig (UKOG-0318FCZZ) to the sensor housing section. Engage the calibration jig with the projection of the sensor housing, and slide it to the rear frame side. 5) Close the right paper transport unit, and manually turn ON the front door switch. 6) Press [EXECUTE] key. Color image density sensor (image registration sensor F) cali- bration is automatically exec uted. When the operation is com- pleted, the adjustment result is displayed and [EXECUTE] key returns to the normal display. If the adjustment is not completed normally, ERROR is dis- played. When an error occurs, the adjustment result is not revised. In that case, check the following sections for any abnormality. If any abnormality is found, repair and execute calibration again. * Color image density sensor (image registration sensor F) * PCU PWB * Image sensor calibration jig (dirt, scratch, discoloration) * Image density sensor standard reflection plate (dirt, scratch, discoloration) The message is displayed, indicating that the jig is removed and the primary transfer unit is installed. 7) Remove the jig and install the BK developing unit, the BK OPC drum unit, and the primary transfer unit, and close the right paper transport unit. 8) [EXECUTE] key is pressed again. The image sensor calibration jig must be stored at lower tempera- tures and low humidity without external lights. When this adjustment is execut ed, perform the ADJ10B copy/ printer color balance adjustment with SIM46-74.
MX-3610N ADJUSTMENTS AND SETTINGS 4 – 12 3-BImage density sensor adjustment The image density sensor standard reflection plate and the transfer belt surface are used to make the sensitivity adjustment of the color image density sensor (image regist ration sensor F) and the black image density sensor (image registration sensor R). This adjustment executes automatical ly at the outset of registration adjustment operation and process control operation as well as SIM44-2. Normally, therefore, it is not r equired to perform this adjustment. It is performed only when the sensor is replaced or when the adjust- ment result is checked. 1) Enter SIM44-2 mode. 2) Press [EXECUTE] key. The sensitivity adjustments of the color image density sensor (image registration sensor F) and the black image density sen- sor (image registration sensor R) are automatically performed. After completion of the adjustment, the adjustment result is displayed and [EXECUTE] key returns to the normal display. If the adjustment is not completed normally, ERROR is dis- played. When an error occurs, check the fo llowing sections for any abnor- mality. • Color image density sensor (image registration sensor F) • Black image density sensor (i mage registration sensor R) •PCU PWB • Transfer belt (dirt, scratch) • Transfer belt cleaner • Image density sensor standard reflection plate (dirt, scratch, dis- coloration) If any abnormality is found, repair and adjust again. If an error occurs, the adjustment result is not revised. ADJ 4Image lead edge position, image loss, void area, image off-center, image magnification ratio adjustment (Automatic adjustment) The following adjustment items can be executed automatically with SIM50-28. *ADJ 15 Print image position, image magnification ratio, void area, off- center adjustment (Print engine) (Manual adjustment) *ADJ 16 Scan image magnification ratio adjustment (Manual adjustment) *ADJ 17 Scan image off-center adjustment (Manual adjustment) *ADJ 18 Copy image position, image loss adjustment (Manual adjustment) (Menu in SIM50-28 mode) 4-A Print image main scanning direction automatic magnification ratio adjustment (Print engine) 1) Enter the SIM50-28 mode. 2) Select [BK-MAG ADJ] with the key. Mode Error display Error content Adjustment value for process control operation mode BK_SEN_ ADJ_ERR Black image density sensor adjustment abnormality PCS_K LED ADJ error (The target value is not obtained after retried three times.) CL_SEN_ ADJ_ERR Color image density sensor adjustment abnormality PCS_CL LED ADJ error (The target value is not obtained after retried three times.) BELT_READ_ ERR Transfer belt surface reading abnormality PCS_K GRND error (The surface detection level is maximum or the minimum value difference is outside a reference range.) Adjustment value for image registration operation mode REG_SEN_ F_ADJ_ERR Registration sensor F adjustment abnormality REG_F LED ADJ error (The target value is not obtained after retried three times.) REG_SEN_ R_ADJ_ERR Registration sensor R adjustment abnormality REG_R LED ADJ error (The target value is not obtained after retried three times.) REG_BELT_ F_READ_ ERR F side transfer belt surface reading abnormality REG_F GRND error (The surface detection level is maximum or the minimum value difference is outside a reference range.) REG_BELT_ R_READ_ ERR R side transfer belt surface reading abnormality REG_R GRND error (The surface detection level is maximum or the minimum value difference is outside a reference range.)
MX-3610N ADJUSTMENTS AND SETTINGS 4 – 13 3) Select the paper feed tray with paper in it with the key. (Any paper size will do.) 4) Press [EXECUTE] key. The adjustment pattern is printed out. 5) Set the adjustment pattern on the document table. Fit the adjustment pattern correctly with the document guide. In this case, put 5 sheets of white paper on the printed adjust- ment pattern. 6) Press [EXECUTE] key. The following item is automatically adjustment. * Print image main scanning direction image magnification ratio. 7) Press [OK] key. The adjustment result becomes valid. 4-B Print image off-center automatic adjustment (Print engine) (Each paper feed tray) 1) Enter the SIM50-28 mode. 2) Select [SETUP/PRINT ADJ] with the key. 3) Select [ALL] with the key. By pressing [LEAD] or [OFFSET] key, the following items can be executed individually. * [LEAD]: Print image lead edge image position adjustment * [OFFSET]: Print image off-center adjustmentWhen [ALL] is selected, both of the above two items are executed simultaneously.
MX-3610N ADJUSTMENTS AND SETTINGS 4 – 14 4) Select a paper feed tray to be adjusted. 5) Press [EXECUTE] key. The adjustment pattern is printed out. 6) Set the adjustment pattern on the document table. Fit the adjustment pattern correctly with the document guide. In this case, put 5 sheets of white paper on the printed adjust- ment pattern. 7) Press [EXECUTE] key. The following item is automatically adjustment. * Print image lead edge image position adjustment * Print image off-center adjustment 8) Press [OK] key. The adjustment result becomes valid. Perform procedures 4) to 7) for each paper feed tray. 4-C Copy mode image lead edge position, image loss, void area, image off-center, sub scanning direction image magnification ratio automatic adjustment (Scanner) (Document table mode) 1) Enter the SIM50-28 mode. 2) Select [OC ADJ] with the key. 3) Select the paper feed tray with paper in it with the key. (Any paper size will do.) 4) Press [EXECUTE] key. The adjustment pattern is printed out. 5) Set the adjustment pattern on the document table. Fit the adjustment pattern correctly with the document guide. In this case, put 5 sheets of white paper on the printed adjust- ment pattern. 6) Press [EXECUTE] key. The following item is automatically adjustment. * Copy lead edge image reference position adjustment, imageoff-center, sub scanning direct ion image magnification ratio automatic adjustment