    							ENGLISH
    FU-S51EFU-S51A
    AIR PURIFIER
    OPERATION MANUAL
    R
    Free Standing
    *Plasmacluster is a trademark ofSharp Corporation.
    *Plasmacluster 是聲寶公司的商標 
    						
    							     Please read before operating your new Air Purifier
    The air purifier draws in room air from its air intake, lets the air pass through a
    Active Carbon Filter (deodorization filter) and a HEPA Filter (dust collection
    filter) inside of the unit, then discharges the air from its air outlet. The air
    purifier unit repeats this process by moving its internal fan.
    As air passes through, a new HEPA Filter can remove 99.97% of dust parti-
    cles, of as small as 0.3 microns. The Active Carbon Filter gradually absorbs
    odour elements as they repeatedly pass through the filter. (Odour elements
    are absorbed by HEPA Filter as well.)
    Some odour ingredients absorbed by the filters may become separated and
    may be discharged through the air outlet and result in additional odour. De-
    pending on the usage environment, especially when the product is used in a
    condition significantly more severe than household use, this odour may be-
    come strong in a shorter period than expected.
    If the odour persists, then the filters are fully expended and it is necessary to
    purchase the optional replacement filter.
    NOTE
    •The air purifier is designed to remove air-suspended dust and odour, but not harmful gases (for
    example, carbon monoxide contained in cigarette smoke).  If the odour sources still exist, it cannot
    completely remove the odour. (for example, odours from construction materials and pet odours).
    •It is suggested to open the window a bit when you are smoking in order to facilitate ventilation. 
    						
    							ENGLISH
    FEATURES
    ION SHOWER
    E-1
    ENGLISH
    Thank you for purchasing the SHARP Air Puri-
    fier. Please read this manual carefully for the cor-
    rect usage information. Before using this prod-
    uct, be sure to read the section: “Important Safety
    Instructions.”
    After reading this manual, retain it in a conven-
    ient location for future reference.
    IMPORTANT SAFETY INSTRUCTIONS ....E-2
    •WARNING ....................................................E-2
    •CAUTIONS CONCERNING OPERATION ...E-3
    •INSTALLATION GUIDELINES .....................E-3
    •FILTER GUIDELINES ..................................E-3
    PART NAMES ..........................................E-4
    •MAIN UNIT DISPLAY ...................................E-4
    •ILLUSTRATIVE DIAGRAM ..........................E-4
    •BACK ...........................................................E-5
    •INCLUDED ...................................................E-5
    PREPARATION ........................................E-6
    •FILTER INSTALLATION ...............................E-6
    OPERATION ............................................E-8
    •MAIN UNIT OPERATION .............................E-8
    CARE AND MAINTENANCE .................E-10
    •MAIN UNIT ................................................E-10
    •FILTER ......................................................E-10
    •SENSORS ................................................E-10
    •WASHABLE ACTIVE CARBON FILTER CARE ....E-11
    •FILTER  REPLACEMENT
    GUIDELINES ............................................E-12
    SPECIFICATIONS .................................E-12
    TROUBLESHOOTING ...........................E-13
    CONTENTS
    New ION SHOWER Operation Mode
    releases the concentrated Plasmacluster
    Ions, and effectively removes the pollen
    and mold, and also controls the activity of
    airborne virus, mold, and allergen.
    Plasmacluster Ion Control
    Your new air purifier will control the ratio
    of negative ions and positive ions de-
    pending on the condition of the room.
    •Clean Mode
    Approximately the same numbers of
    positive and negative ions are dis-
    charged.
    •AUTO Plasmacluster Ion
    Mode
    The unit will switch between Clean Mode
    and Ion Control  Mode*  automatically
    depending on the amount of impurities
    in the air detected by the odour and dust
    sensors.
    *Ion Control Mode
    Negative ions will be released in an
    increased rate and controls the ion
    balance.
    •Filters
    1) Washable Active Carbon Filter
    Absorbs odour elements.
    Washable to maintain optimum
    deodorization performance.
    2)HEPA (High Efficiency
    Particulate Air) Filter with
    Microbial Control
    High-efficiency particle collection in-
    cluding pollen and dust. 
    						
    							E-2
    IMPORTANT SAFETY INSTRUCTIONS
    When using electrical appliances, basic safety precautions should be followed, including the
    following:
    WARNING - To reduce the risk of electrical shock, fire or injury to persons:
    •Read all instructions before using the air purifier.
    •Use only a 220 volt outlet with a polarized receptacle.
    •Do not use the air purifier if the power cord or plug is damaged or the connection to the wall
    outlet is loosened.
    •Periodically remove dust from the power plug.
    •Do not insert fingers or foreign objects into the intake or air outlet.
    •When removing the power plug, always hold the plug and never pull the cord.
    Electrical shock and/or fire from short circuit may occur as a  result.
    •Do not remove the plug when your hands are wet.
    •Do not use this air purifier near gas appliances or fireplaces.
    •Remove the power plug from the wall outlet before cleaning the unit and when not using the
    unit.
    Electrical shock from bad insulation and/or fire from short circuit may occur as a result.
    •If the power cord is damaged, it must be replaced by the manufacturer, its service agent,
    Sharp authorized Service Centre or similarly qualified person in order to avoid a hazard.
    •Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,
    sparks from lit cigarettes, chemical fumes in the air or in very high humidity condition, such as a
    bathroom.
    •Be cautious when cleaning the air purifier. Strong corrosive cleansers may damage the exterior.
    •Only Sharp Authorized Service Centre should service this air purifier. Contact the nearest Service
    Centre for any problems, adjustments, or repairs.
    NOTE - Radio or TV Interference
    If this air purifier should cause  interference to radio or television reception, try to correct the interference
    by one or more of the following measures:
    •Reorient or relocate the receiving antenna.
    •Increase the separation distance between the air purifier and radio/TV receiver.
    •Connect the equipment into an outlet on a circuit different from that to which the receiver is con-
    nected.
    •Consult the dealer or an experienced radio/TV technician for help. 
    						
    							ENGLISH
    E-3
    CAUTIONS CONCERNING OPERATION
    •Do not block the intake and air outlet.
    •Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into
    contact with steam.
    •Do not lay the unit down when using.
    •Always hold the handle on the back of the unit when moving it.
    Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in
    bodily injury.
    •Do not operate the unit without the filter.
    •Do not wash and reuse HEPA filter .
    It not only does not improve filter performance, it may cause electric shock or malfunction.
    •Clean the exterior with a soft cloth only.
    The unit surface may be damaged or cracked.
    In addition, the sensors may malfunction as a result.
    IMPORTANT SAFETY INSTRUCTIONS
    INSTALLATION GUIDELINES
    •During the operation of the product, please place the unit at least 2m away from equipments
    which involve electric wave such as televisions, radios or wave clocks, in case electrical
    interference occurs to such equipment.
    •Avoid a location where the sensor is exposed to direct wind.
    The unit may not operate properly.
    •Avoid locations where curtains, etc., come into contact with the intake or air outlet.
    Curtains, etc., may become dirty or a malfunction may occur.
    •Avoid locations where the unit is exposed to condensation, due to drastic temperature changes.
    (Use under appropriate conditions between 0 and 35˚C in the room.)
    •Place on a stable surface with sufficient air circulation.
    When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly.
    •Do not install when there is generation of lampblack, such as in a kitchen, etc.
    The unit surface may crack or the sensor may malfunction as a result.
    •Leave about  60cm of space from the wall.
    The wall behind the air outlet may become dirty as time passes. When using the unit for  extended
    period of time  in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In
    addition, periodically clean the wall.
    FILTER GUIDELINES
    •Follow the instructions in this manual for correct care and maintenance of the filters. 
    						
    							E-4
    PART NAMES
    MAIN UNIT DISPLAY
    ILLUSTRATIVE  DIAGRAM
    Odour Sensor Date Label
    Main Unit
    HEPA Filter
    (blue / white)
    Filter Support
    Front Panel
    Washable Active 
    Carbon Filter
    AUTO Operation Indicator Light
    Pollen Mode Indicator Light
    Fan Speed  Indicator Lights
    Plasmacluster Ion Mode 
    Indicator Lights
    Plasmacluster Ion Mode 
    Selection Button
    Mode Selection Button
    ION SHOWER Indicator Light
    ION SHOWER Mode Button
    POWE 
    						
    							ENGLISH
    E-5
    INCLUDED
    •Operation manual
    BACK
    Blue light
    When the Plasmacluster ion operation is in Clean Mode, or in AUTO Plasmaclus-
    ter Ion Mode and the air in the room is impure, the light will be activated and the
    unit will operate in Clean Mode.
    Green light
    When the Plasmacluster ion operation is in the Ion Control  Mode during AUTO
    Plasmacluster Ion Mode and the air in the room is clean, this light will be activated
    and the unit will operate in Ion Control Mode.
    Cycles of blue and green
    When the Plasmacluster ion operation is in the ION SHOWER Mode ,
    Plasmacluster Indicator Light will repeat its colour cycles between blue and green.
    The colour changes according to
    the air condition.
    ABOUT THE CLEAN-SIGN
    •The condition of the CLEAN-SIGN depends on the room air condition detected
    by the Dust and Odour Sensors when the plug is inserted into the wall outlet.
    •It is possible to have a green CLEAN-SIGN with impurities in the air at the time
    that the air purifier was just introduced to the room environment. After a while,
    however, the base impurity rate will be adjusted to detect room air condition
    correctly.
    DETERMINING THE BASE IMPURITY RATE
    For the first 30 seconds after the power plug is inserted into the wall outlet, the
    unit will check the conditions of the air. If operation is set to ON during this time,
    the CLEAN-SIGN LIGHT will alternately flash in green, yellow and red.
    Plasmacluster Indicator Light
    (Please refer page E-9)
    CLEAN - SIGN Light
    POWER ON/OFF Button
    ENGLISH
    GreenClean Slightly Impure Very Impure
    Yellow Red
    Air Outlet
    Air Inlet Rating Label
    Power Cord 
    Power Plug Handle 
    Dust Sensor 
    						
    							PREPARATION
    To maintain the quality of the filters, they are installed in the main unit and packed in
    plastic bags. Be sure to remove the filters from the plastic bags before using the unit.
    Remove the filters
    Remove the Front Panel.
    E-6
    Be sure to remove the power plug from the wall outlet.
    FILTER INSTALLATION
    Remove the Filter Support.
    Pull the Front Panel on the
    lower sides, and lift up.
    4 2 1
    3
    Front Panel
    (At open)1
    5
    Push in the hooks on top, then pull the Filter Support.
    Remove the HEPA Filter.
    Remove the HEPA Filter from the
    plastic bag.
    Remove the Active Carbon Filter from
    the carton box, and also remove from
    the plastic bag.
    Filter Support
    HEPA Filter
    HEPA Filter
    Active Carbon Filter 
    						
    							ENGLISH
    Ta b
    (blue)
    E-7
    2 1
    3
    4
    5
    )
    2Install the filters
    Place the HEPA Filter into the
    main unit.
    Do not install the filter backwards or the
    unit will not operate properly.
    Place the Filter Support
    through the bands (2 places)
    located at the corners of the
    Active Carbon Filter.
    Replace the Filter Support and Active
    Carbon Filter back to the main unit.
    Fill in the usage start date on the
    Date Label.
    Use the date as a guide for the Filter
    Replacement schedule.
    Replace the Front Panel.
    Date Label
    HEPA Filter
    Filter SupportBand(blue)
    Active Carbon Filter
    Filter Support
    Front PanelPlace the Front Panel from the obliquely upward,
    then mount the hooks at the bottom.
    Please make sure that the  HEPA
    Filter(blue) and the tab  is placed in
    proper direction. 
    						
    							OPERATION
    MAIN UNIT OPERATION
    E-8
    Power ON/OFF Button
    •Used to start operation (short beep) and stop operation (long beep)
    •Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off.
    •Unless unplug the power cord, the operation starts in the previous mode the
    unit was operated in.
    •When stop operation during ION SHOWER Operation, the unit will back to the
    prior operation of ION SHOWER Operation.
    MODE Selection Button
    •The operation mode can be switched.
    AUTO operation
    The fan speed is automatically switched
    (HIGH*, MEDIUM, SILENT) depending
    on the amount of impurities in the air. The
    sensors detect the impurities  for efficient
    air purification.
    POLLEN mode operation
    The unit will operate at HIGH* fan speed
    for 10 minutes, then will alternate   be-
    tween MEDIUM and HIGH* for 20 min-
    utes.
    10 minutes: HIGH fan speed
    20 minutes: 
    MEDIUM fan speed
    20 minutes: HIGH fan speed
    SILENT operation
    The unit will operate quietly
    using minimal air intake.
    MEDIUM operation
    The unit will operate at a fan
    speed of MEDIUM.
    MAX operation
    The unit will operate at a fan
    speed of MAX.
    *HIGH fan speed is an intermediate speed
    between MEDIUM  and MAX.
    Plasmacluster Ion Mode 
    Selection Button Mode Selection Button 
    						
    All Sharp manuals Comments (0)

    Related Manuals for Sharp Fus51aw Manual