ENGLISH FU-S51EFU-S51A AIR PURIFIER OPERATION MANUAL R Free Standing *Plasmacluster is a trademark ofSharp Corporation. *Plasmacluster 是聲寶公司的商標
Please read before operating your new Air Purifier The air purifier draws in room air from its air intake, lets the air pass through a Active Carbon Filter (deodorization filter) and a HEPA Filter (dust collection filter) inside of the unit, then discharges the air from its air outlet. The air purifier unit repeats this process by moving its internal fan. As air passes through, a new HEPA Filter can remove 99.97% of dust parti- cles, of as small as 0.3 microns. The Active Carbon Filter gradually absorbs odour elements as they repeatedly pass through the filter. (Odour elements are absorbed by HEPA Filter as well.) Some odour ingredients absorbed by the filters may become separated and may be discharged through the air outlet and result in additional odour. De- pending on the usage environment, especially when the product is used in a condition significantly more severe than household use, this odour may be- come strong in a shorter period than expected. If the odour persists, then the filters are fully expended and it is necessary to purchase the optional replacement filter. NOTE •The air purifier is designed to remove air-suspended dust and odour, but not harmful gases (for example, carbon monoxide contained in cigarette smoke). If the odour sources still exist, it cannot completely remove the odour. (for example, odours from construction materials and pet odours). •It is suggested to open the window a bit when you are smoking in order to facilitate ventilation.
ENGLISH FEATURES ION SHOWER E-1 ENGLISH Thank you for purchasing the SHARP Air Puri- fier. Please read this manual carefully for the cor- rect usage information. Before using this prod- uct, be sure to read the section: “Important Safety Instructions.” After reading this manual, retain it in a conven- ient location for future reference. IMPORTANT SAFETY INSTRUCTIONS ....E-2 •WARNING ....................................................E-2 •CAUTIONS CONCERNING OPERATION ...E-3 •INSTALLATION GUIDELINES .....................E-3 •FILTER GUIDELINES ..................................E-3 PART NAMES ..........................................E-4 •MAIN UNIT DISPLAY ...................................E-4 •ILLUSTRATIVE DIAGRAM ..........................E-4 •BACK ...........................................................E-5 •INCLUDED ...................................................E-5 PREPARATION ........................................E-6 •FILTER INSTALLATION ...............................E-6 OPERATION ............................................E-8 •MAIN UNIT OPERATION .............................E-8 CARE AND MAINTENANCE .................E-10 •MAIN UNIT ................................................E-10 •FILTER ......................................................E-10 •SENSORS ................................................E-10 •WASHABLE ACTIVE CARBON FILTER CARE ....E-11 •FILTER REPLACEMENT GUIDELINES ............................................E-12 SPECIFICATIONS .................................E-12 TROUBLESHOOTING ...........................E-13 CONTENTS New ION SHOWER Operation Mode releases the concentrated Plasmacluster Ions, and effectively removes the pollen and mold, and also controls the activity of airborne virus, mold, and allergen. Plasmacluster Ion Control Your new air purifier will control the ratio of negative ions and positive ions de- pending on the condition of the room. •Clean Mode Approximately the same numbers of positive and negative ions are dis- charged. •AUTO Plasmacluster Ion Mode The unit will switch between Clean Mode and Ion Control Mode* automatically depending on the amount of impurities in the air detected by the odour and dust sensors. *Ion Control Mode Negative ions will be released in an increased rate and controls the ion balance. •Filters 1) Washable Active Carbon Filter Absorbs odour elements. Washable to maintain optimum deodorization performance. 2)HEPA (High Efficiency Particulate Air) Filter with Microbial Control High-efficiency particle collection in- cluding pollen and dust.
E-2 IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, basic safety precautions should be followed, including the following: WARNING - To reduce the risk of electrical shock, fire or injury to persons: •Read all instructions before using the air purifier. •Use only a 220 volt outlet with a polarized receptacle. •Do not use the air purifier if the power cord or plug is damaged or the connection to the wall outlet is loosened. •Periodically remove dust from the power plug. •Do not insert fingers or foreign objects into the intake or air outlet. •When removing the power plug, always hold the plug and never pull the cord. Electrical shock and/or fire from short circuit may occur as a result. •Do not remove the plug when your hands are wet. •Do not use this air purifier near gas appliances or fireplaces. •Remove the power plug from the wall outlet before cleaning the unit and when not using the unit. Electrical shock from bad insulation and/or fire from short circuit may occur as a result. •If the power cord is damaged, it must be replaced by the manufacturer, its service agent, Sharp authorized Service Centre or similarly qualified person in order to avoid a hazard. •Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense, sparks from lit cigarettes, chemical fumes in the air or in very high humidity condition, such as a bathroom. •Be cautious when cleaning the air purifier. Strong corrosive cleansers may damage the exterior. •Only Sharp Authorized Service Centre should service this air purifier. Contact the nearest Service Centre for any problems, adjustments, or repairs. NOTE - Radio or TV Interference If this air purifier should cause interference to radio or television reception, try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation distance between the air purifier and radio/TV receiver. •Connect the equipment into an outlet on a circuit different from that to which the receiver is con- nected. •Consult the dealer or an experienced radio/TV technician for help.
ENGLISH E-3 CAUTIONS CONCERNING OPERATION •Do not block the intake and air outlet. •Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam. •Do not lay the unit down when using. •Always hold the handle on the back of the unit when moving it. Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in bodily injury. •Do not operate the unit without the filter. •Do not wash and reuse HEPA filter . It not only does not improve filter performance, it may cause electric shock or malfunction. •Clean the exterior with a soft cloth only. The unit surface may be damaged or cracked. In addition, the sensors may malfunction as a result. IMPORTANT SAFETY INSTRUCTIONS INSTALLATION GUIDELINES •During the operation of the product, please place the unit at least 2m away from equipments which involve electric wave such as televisions, radios or wave clocks, in case electrical interference occurs to such equipment. •Avoid a location where the sensor is exposed to direct wind. The unit may not operate properly. •Avoid locations where curtains, etc., come into contact with the intake or air outlet. Curtains, etc., may become dirty or a malfunction may occur. •Avoid locations where the unit is exposed to condensation, due to drastic temperature changes. (Use under appropriate conditions between 0 and 35˚C in the room.) •Place on a stable surface with sufficient air circulation. When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly. •Do not install when there is generation of lampblack, such as in a kitchen, etc. The unit surface may crack or the sensor may malfunction as a result. •Leave about 60cm of space from the wall. The wall behind the air outlet may become dirty as time passes. When using the unit for extended period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In addition, periodically clean the wall. FILTER GUIDELINES •Follow the instructions in this manual for correct care and maintenance of the filters.
E-4 PART NAMES MAIN UNIT DISPLAY ILLUSTRATIVE DIAGRAM Odour Sensor Date Label Main Unit HEPA Filter (blue / white) Filter Support Front Panel Washable Active Carbon Filter AUTO Operation Indicator Light Pollen Mode Indicator Light Fan Speed Indicator Lights Plasmacluster Ion Mode Indicator Lights Plasmacluster Ion Mode Selection Button Mode Selection Button ION SHOWER Indicator Light ION SHOWER Mode Button POWE
ENGLISH E-5 INCLUDED •Operation manual BACK Blue light When the Plasmacluster ion operation is in Clean Mode, or in AUTO Plasmaclus- ter Ion Mode and the air in the room is impure, the light will be activated and the unit will operate in Clean Mode. Green light When the Plasmacluster ion operation is in the Ion Control Mode during AUTO Plasmacluster Ion Mode and the air in the room is clean, this light will be activated and the unit will operate in Ion Control Mode. Cycles of blue and green When the Plasmacluster ion operation is in the ION SHOWER Mode , Plasmacluster Indicator Light will repeat its colour cycles between blue and green. The colour changes according to the air condition. ABOUT THE CLEAN-SIGN •The condition of the CLEAN-SIGN depends on the room air condition detected by the Dust and Odour Sensors when the plug is inserted into the wall outlet. •It is possible to have a green CLEAN-SIGN with impurities in the air at the time that the air purifier was just introduced to the room environment. After a while, however, the base impurity rate will be adjusted to detect room air condition correctly. DETERMINING THE BASE IMPURITY RATE For the first 30 seconds after the power plug is inserted into the wall outlet, the unit will check the conditions of the air. If operation is set to ON during this time, the CLEAN-SIGN LIGHT will alternately flash in green, yellow and red. Plasmacluster Indicator Light (Please refer page E-9) CLEAN - SIGN Light POWER ON/OFF Button ENGLISH GreenClean Slightly Impure Very Impure Yellow Red Air Outlet Air Inlet Rating Label Power Cord Power Plug Handle Dust Sensor
PREPARATION To maintain the quality of the filters, they are installed in the main unit and packed in plastic bags. Be sure to remove the filters from the plastic bags before using the unit. Remove the filters Remove the Front Panel. E-6 Be sure to remove the power plug from the wall outlet. FILTER INSTALLATION Remove the Filter Support. Pull the Front Panel on the lower sides, and lift up. 4 2 1 3 Front Panel (At open)1 5 Push in the hooks on top, then pull the Filter Support. Remove the HEPA Filter. Remove the HEPA Filter from the plastic bag. Remove the Active Carbon Filter from the carton box, and also remove from the plastic bag. Filter Support HEPA Filter HEPA Filter Active Carbon Filter
ENGLISH Ta b (blue) E-7 2 1 3 4 5 ) 2Install the filters Place the HEPA Filter into the main unit. Do not install the filter backwards or the unit will not operate properly. Place the Filter Support through the bands (2 places) located at the corners of the Active Carbon Filter. Replace the Filter Support and Active Carbon Filter back to the main unit. Fill in the usage start date on the Date Label. Use the date as a guide for the Filter Replacement schedule. Replace the Front Panel. Date Label HEPA Filter Filter SupportBand(blue) Active Carbon Filter Filter Support Front PanelPlace the Front Panel from the obliquely upward, then mount the hooks at the bottom. Please make sure that the HEPA Filter(blue) and the tab is placed in proper direction.
OPERATION MAIN UNIT OPERATION E-8 Power ON/OFF Button •Used to start operation (short beep) and stop operation (long beep) •Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off. •Unless unplug the power cord, the operation starts in the previous mode the unit was operated in. •When stop operation during ION SHOWER Operation, the unit will back to the prior operation of ION SHOWER Operation. MODE Selection Button •The operation mode can be switched. AUTO operation The fan speed is automatically switched (HIGH*, MEDIUM, SILENT) depending on the amount of impurities in the air. The sensors detect the impurities for efficient air purification. POLLEN mode operation The unit will operate at HIGH* fan speed for 10 minutes, then will alternate be- tween MEDIUM and HIGH* for 20 min- utes. 10 minutes: HIGH fan speed 20 minutes: MEDIUM fan speed 20 minutes: HIGH fan speed SILENT operation The unit will operate quietly using minimal air intake. MEDIUM operation The unit will operate at a fan speed of MEDIUM. MAX operation The unit will operate at a fan speed of MAX. *HIGH fan speed is an intermediate speed between MEDIUM and MAX. Plasmacluster Ion Mode Selection Button Mode Selection Button