Page 31
Cancel OK Record Quality & Auto Deletion Cam Normal Event Cam Normal Event 1 Level4 Level4 9 Level4 Level4 2 Level4 Level4 10 Level4 Level4 3 Level4 Level4 11 Level4 Level4 4 Level4 Level4 12 Level4 Level4 5 Level4 Level4 13 Level4 Level4 6 Level4 Level4 14 Level4 Level4 7 Level4 Level4 15 Level4 Level4 8 Level4 Level4 16 Level4 Level4 Off Auto Deletion: 01 Day MENU SETUPSystem Camera Monitoring Record Mode Event Record Schedule Backup...
Page 32
28_ menu setup Record Quality You can set the recording picture quality selecting of Level8(High) ~ Level1(Low). Auto Deletion If you select On, you can set the number of days for access restriction. If it is set to 3, you cannot search the data recorded at the time less than 3 days before. In case of SHR-5082, only 8 channels are displayed. Record Rate & Video Size When you press the RECORD button, the record-related settings are applied. IPS (Images per second) You can set the image...
Page 33
05 MENU SETUP menu setup _29 EVENT RECORD MODE The detailed list for event mode settings is as follows: Alarm Detection Setup Sensor State - Off: Sensor does not operate. - N.O (Normal Open): Sensor remains open all the time. But if it gets closed, an alarm is issued. (A Contact) - N.C (Normal Close): Sensor remains closed all the time. But if it gets open, an alarm is issued. (B Contact) Cam It is used to set a camera that synchronizes with the current sensor. The default setting...
Page 34
30_ menu setup Sensitivity This is used to set the sensitivity for motion detection. Available values are Low, Medium, and Very High. Alarm-Out It is used to set the Alarm-Out location when any alarm occurs. Currently 5 Alarm Outs are available. Select an alarm-out to synchronize w ith the current sensor. But multiple values can be selected. Duration It is used to set the Alarm-Out duration. When an alarm occurs, the alarm is output for the preset time. You can select any of Off, 3sec,...
Page 35
05 MENU SETUP menu setup _31 In case of SHR-5082, only 8 channels are displayed. Alarm Out Schedule You can schedule the automatic output for alarms. The scheduling is enabled by selecting alarms, days and time blocks. The default setting is Event Driven. For each alarm or beep, you can activate or deactivate alarming. In case of Event Driven, the alarm can be sent only when an event is issued. AO >: It indicates Alarm Out. All alarms are changed according to Alarm1 when it pressed. 0...
Page 36
32_ menu setup IP Set the IP address for the main body of the product for connecting to the network. If the connection mode is set to Static IP, type the IP address. If the connection mode is Dynamic IP or ADSL(PPPoE), the IP address allocated by the DHCP server or ADSL company automatically appears. In case of DHCP or ADSL connection failure, the value “000.000.000.000” is displayed. Then, press OK to retry connection for getting the IP address. If the connection failure continues, turn off...
Page 37
If you set up the public DDNS (dyndns. c om, no-ip.com, or changeip.com), it will take approximately 30 to 60 seconds to get the IP address for the host name (URL) to be updated in the DNS. To connect this product to an IP router, you have to designate a port for this product in the setup menu of the router. This product has 4 ports for TCP communication. To use the DHCP function provided by the IP router to allocate the dynamic IP to the product, designate a port for the IP that has been...
Page 38
34_ menu setup CONFIGURING NETWORK Port configuration for connecting Smart Viewer To set the TCP port for DVR registration into Smart Viewer, the value should be the same as that of this product. To use the IP router, you must forward the activated ports. - For TCP, set the assigned 4 ports in the IP Router. - For UDP, set the assigned 4 TCP ports and 160 UDP ports that is set in the IP Router. In case of TCP transfer protocol The ports allocated to the TCP will be used for connection...
Page 39
backup _35 06 BACKUP If there is a predefined device connected, the window displays the device information like the free space and such. You can also use the BACKUP button on the front of your DVR. To configure the related settings 1. Set the start date and time using the Direction buttons and the ENTER button. 2. Set the end date and time using the Direction buttons and the ENTER button. 3. Select a channel for backup using the Direction buttons and the ENTER button. 4. Optional: If you...
Page 40
36_ PTZ camera control PTZ CAMERA CONTROL MODE You have to check that proper PTZ camera settings are allocated for PTZ device setup in the Camera menu. In case of SHR-5082, only 8 channels are displayed. W hen the PTZ configuration is complete, the PTZ sign ( PTZ ) appears on the live screen. If you press the ENTER button in the split screen, a blue bar appears for selection handling. Use the Direction buttons to move this bar until you reach the channel having the PTZ sign, and press the...