4.4.1.139 EXT_INT7CON 
 Base Address: 0x1140_0000 
 Address = Base Address + 0x0718, Reset Value = 0x0000_0000 
Name Bit Type Description Reset Value 
RSVD [31:16] –=Reserved=0x0000=
RSVD=[15]=–=Reserved=0x0=
EXT_INT7=
_CON[3]=[14:12]=RW=
Setting the signaling method=of EXT_INT7[3]=
0x0 = Sets Low level=
0x1 = Sets High level=
0x2 = Triggers Falling edge =
0x3 = Triggers Rising edge==
0x4 = Triggers Both edge==
0x5 to 0x7 = Reserved=
0x0=...

Page 152

Samsung Confidential  
Exynos 5250_UM 4 Pad Control 
 4-98  
4.4.1.140 EXT_INT8CON 
 Base Address: 0x1140_0000 
 Address = Base Address + 0x071C, Reset Value = 0x0000_0000 
Name Bit Type Description Reset Value 
RSVD [31:28] –=Reserved=0x0=
RSVD=[27]=–=Reserved=0x0=
EXT_INT8=
_CON[6]=[26:24]=RW=
Setting the signaling method=of EXT_INT8[6]=
0x0 = Sets Low level=
0x1 = Sets High level=
0x2 = Triggers Falling edge =
0x3 = Triggers Rising edge==
0x4 = Triggers Both edge==
0x5 to 0x7 = Reserved=
0x0=...

Page 153

Samsung Confidential  
Exynos 5250_UM 4 Pad Control 
 4-99  
Name Bit Type Description Reset Value 
EXT_INT8 
_CON[1] [6:4] RW 
Setting the signaling method of EXT_INT8[1] 
0x0 = Sets Low level 
0x1 = Sets High level 
0x2 = Triggers Falling edge  
0x3 = Triggers Rising edge  
0x4 = Triggers Both edge  
0x5 to 0x7 = Reserved 
0x0 
RSVD [3] – Reserved 0x0 
EXT_INT8 
_CON[0] [2:0] RW 
Setting the signaling method of EXT_INT8[0] 
0x0 = Sets Low level 
0x1 = Sets High level 
0x2 = Triggers Falling edge  
0x3...

Page 154

Samsung Confidential  
Exynos 5250_UM 4 Pad Control 
 4-100  
4.4.1.141 EXT_INT9CON 
 Base Address: 0x1140_0000 
 Address = Base Address + 0x0720, Reset Value = 0x0000_0000 
Name Bit Type Description Reset Value 
RSVD [31:16] –=Reserved=0x0000=
RSVD=[15]=–=Reserved=0x0=
EXT_INT9=
_CON[3]=[14:12]=RW=
Setting the signaling method=of EXT_INT9[3]=
0x0 = Sets Low level=
0x1 = Sets High level=
0x2 = Triggers Falling edge =
0x3 = Triggers Rising edge==
0x4 = Triggers Both edge==
0x5 to 0x7 = Reserved=
0x0=...

Page 155

Samsung Confidential  
Exynos 5250_UM 4 Pad Control 
 4-101  
4.4.1.142 EXT_INT10CON 
 Base Address: 0x1140_0000 
 Address = Base Address + 0x0724, Reset Value = 0x0000_0000 
Name Bit Type Description Reset Value 
RSVD [31:28] –=Reserved=0x0=
RSVD=[27]=–=Reserved=0x0=
EXT_INT10=
_CON[6]=[26:24]=RW=
Setting the signaling method=of EXT_INT10[6]=
0x0 = Sets Low level=
0x1 = Sets High level=
0x2 = Triggers Falling edge =
0x3 = Triggers Rising edge==
0x4 = Triggers Both edge==
0x5 to 0x7 = Reserved=
0x0=...

Page 156

Samsung Confidential  
Exynos 5250_UM 4 Pad Control 
 4-102  
Name Bit Type Description Reset Value 
EXT_INT10 
_CON[1] [6:4] RW 
Setting the signaling method of EXT_INT10[1] 
0x0 = Sets Low level 
0x1 = Sets High level 
0x2 = Triggers Falling edge  
0x3 = Triggers Rising edge  
0x4 = Triggers Both edge  
0x5 to 0x7 = Reserved 
0x0 
RSVD [3] – Reserved 0x0 
EXT_INT10 
_CON[0] [2:0] RW 
Setting the signaling method of EXT_INT10[0] 
0x0 = Sets Low level 
0x1 = Sets High level 
0x2 = Triggers Falling edge...

Page 157

Samsung Confidential  
Exynos 5250_UM 4 Pad Control 
 4-103  
4.4.1.143 EXT_INT11CON 
 Base Address: 0x1140_0000 
 Address = Base Address + 0x0728, Reset Value = 0x0000_0000 
Name Bit Type Description Reset Value 
RSVD [31:28] –=Reserved=0x0=
RSVD=[27]=–=Reserved=0x0=
EXT_INT11=
_CON[6]=[26:24]=RW=
Setting the signaling method=of EXT_INT11[6]=
0x0 = Sets Low level=
0x1 = Sets High level=
0x2 = Triggers Falling edge =
0x3 = Triggers Rising edge==
0x4 = Triggers Both edge==
0x5 to 0x7 = Reserved=
0x0=...

Page 158

Samsung Confidential  
Exynos 5250_UM 4 Pad Control 
 4-104  
Name Bit Type Description Reset Value 
EXT_INT11 
_CON[1] [6:4] RW 
Setting the signaling method of EXT_INT11[1] 
0x0 = Sets Low level 
0x1 = Sets High level 
0x2 = Triggers Falling edge  
0x3 = Triggers Rising edge  
0x4 = Triggers Both edge  
0x5 to 0x7 = Reserved 
0x0 
RSVD [3] – Reserved 0x0 
EXT_INT11 
_CON[0] [2:0] RW 
Setting the signaling method of EXT_INT11[0] 
0x0 = Sets Low level 
0x1 = Sets High level 
0x2 = Triggers Falling edge...

Page 159

Samsung Confidential  
Exynos 5250_UM 4 Pad Control 
 4-105  
4.4.1.144 EXT_INT12CON 
 Base Address: 0x1140_0000 
 Address = Base Address + 0x072C, Reset Value = 0x0000_0000 
Name Bit Type Description Reset Value 
RSVD [31:16] –=Reserved=0x0000=
RSVD=[15]=–=Reserved=0x0=
EXT_INT12=
_CON[3]=[14:12]=RW=
Setting the signaling method=of EXT_INT12[3]=
0x0 = Sets Low level=
0x1 = Sets High level=
0x2 = Triggers Falling edge =
0x3 = Triggers Rising edge==
0x4 = Triggers Both edge==
0x5 to 0x7 = Reserved=...

Page 160

Samsung Confidential  
Exynos 5250_UM 4 Pad Control 
 4-106  
4.4.1.145 EXT_INT13CON 
 Base Address: 0x1140_0000 
 Address = Base Address + 0x0730, Reset Value = 0x0000_0000 
Name Bit Type Description Reset Value 
RSVD [31] –=Reserved=0x0=
EXT_INT13=
_CON[7]=[30:28]=RW=
Setting the signaling method=of EXT_INT13[7]=
0x0 = Sets Low level=
0x1 = Sets High level=
0x2 = Triggers Falling edge =
0x3 = Triggers Rising edge==
0x4 = Triggers Both edge==
0x5 to 0x7 = Reserved=
0x0=
RSVD=[27]=–=Reserved=0x0=...
Start reading Samsung Exynos 5 User Manual
All Samsung manuals