External Control PlasmaWall XP Series Installation/Operation Manual 65 PREL IMINARY Aspect Ratio Commands 16:9NAYESSelects the 16:9 aspect ratio 4:3NAYESSelects the 4:3 aspect ratio ASPECT?NANAReturns current aspect ratio CINEMANAYESSelects the Cinema aspect ratio LETTERBOXNAYESSelects the Letterbox aspect ratio NATIVENAYESSelects the Native aspect ratio VIRTUALWIDENAYESSelects the VirtualWide aspect ratio VIRTUALCINEMANAYESSelects the Virtual Cinema aspect ratio Picture Adjust Commands BRIGHTNESS-50/50YESSets a value for brightness BRIGHTNESS?NANAReturns brightness setting value CHROMADELAY-7/7YESSets a value for input color chroma delay CHROMADELAY?NANAReturns input color chroma delay setting COLOR-50/50YESSets a value for color COLOR?NANAReturns color setting value CONTRAST-50/50YESSets a value for contrast CONTRAST?NANAReturns contrast setting value FILMMODE0/1YESSets Film Mode off (0) or on (1) FILMMODE?NANAReturns Film Mode setting (0 = off; 1 = on) FILTER0/10YESSets a value for input color noise filter FILTER?NANAReturns input color noise filter setting PHASE0/31YESAdjusts phase PHASE?NANAReturns phase setting value SHARPNESS-50/50YESSets a value for sharpness SHARPNESS?NANAReturns sharpness setting value TINT-50/50YESSets a value for tint TINT?NANAReturns tint setting value Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
External Control 66 PlasmaWall XP Series Installation/Operation Manual PRELI MINARY Image Preset Commands CUSTOM1NAYESLoads “Custom 1” image preset CUSTOM2NAYESLoads “Custom 2” (“THX”) image preset DAYNAYESLoads “ISF Day” image preset NIGHTNAYESLoads “ISF Night” image preset PRESET?NANAReturns currently-selected preset (ISF Day, ISF Night, Custom 1 or Custom 2/THX) Input Position Commands IHEIGHT0/20YESSets the value for input height IHEIGHT?NANAReturns input height value IHPOS-50/50YESSets a value for horizontal input position IHPOS?NANAReturns input horizontal position value IVPOS-50/50YESSets a value for vertical input position IVPOS?NANAReturns input vertical position value IWIDTH0/50YESSets the value for input width IWIDTH?NANAReturns input horizontal width value OVERSCAN 0/20YESSets the overscan percentage OVERSCAN?NANAReturns overscan percentage OVERSCANMODE 0/1YESSets the overscan mode (0=zoom; 1=crop) OVERSCANMODE?NANAReturns the overscan mode (0=zoom; 1=crop) Output Shift Commands OHEIGHT-50/50YESSets the value for output height OHEIGHT?NANAReturns output height value OHPOS-50/50YESSets the value for output horizontal posi- tion OHPOS?NANAReturns output horizontal position value OVPOS-50/50YESSets the value for output vertical position OVPOS?NANAReturns output vertical position value OWIDTH-50/50YESSets the value for output width OWIDTH?NANAReturns output horizontal width value Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
External Control PlasmaWall XP Series Installation/Operation Manual 67 PREL IMINARY Miscellaneous Commands DISPLAY?NANAReturns display device input source value, as follows: 1 = Auto 22 = XP-50DHD 23 = XP-65DHD 24 = XP-103DHD INRES?NANAReturns input resolution MODEL?NANAReturns product model name OUTRES?NANAReturns output resolution SERNUM?NANAReturns DHD Controller serial number SWVER?NANAReturns software version number SYSSTATE?0/4NAReturns current system state 0 = Off 1 = Initializing 2 = On 3 = Powering Down 4 = Error TRIGGER1/3YESAssigns trigger to currently-selected aspect ratio The following serial commands are meant to emulate buttons on the remote control or DHD Con- troller front panel. Each button has its own serial command, so effectively it is as if you were using the IR remote only you’ll be doing so via serial commands. These commands provide active OSD responses just like the IR remote. DOWNNANADown-Arrow () key ENTERNANAENTER key EXITNANAEXIT (RETURN) key LEFTNANALeft-Arrow () key MENUNANAMENU RIGHTNANARight-Arrow () key UPNANAUp-Arrow () key Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
External Control 68 PlasmaWall XP Series Installation/Operation Manual PRELI MINARY 6.2 Using Discrete IR Codes The DHD Controller accepts commands in the form of IR signals that conform to the Phillips RC5 protocol. Each DHD Controller remote control button has an RC5 control code associated with it. You can use these codes to program a third-party, “universal” remote control unit to work with the DHD Controller. These third-party products usually come with a computer software application for this purpose. For more information, consult the documentation provided with the remote control unit. IR Command ProtocolThe IR control codes have the following characteristics: Each code consists of 14 bits: Two (2) start bits (always 1); A toggle bit. This bit is inverted every time a key is released and pressed again. This allows the DHD Controller to distinguish between a button that remains down or is pressed repeatedly. Five (5) address bits. The default address is 17 (binary 10001). To change it, select Remote Control from the Service menu and follow the steps given on page 54. Six (6) data bits. The carrier frequency is 36 kHz, with the modulated pulses having a 25% duty cycle. Commands are sent at a maximum rate of 9 Hz. For example, here is the RC5 control code for the ON button on the DHD Controller remote control unit (assuming the default address is used): ➤ With Toggle Bit = 0 Hex3441 Binary11010001000001 With Toggle Bit = 1 Hex3C41 Binary11110001000001 FunctionStart BitsToggle BitAddressCommand
External Control PlasmaWall XP Series Installation/Operation Manual 69 PREL IMINARY Figure 6-1 shows the pulse train for this command (with the toggle bit set to zero). Figure 6-1. RC5 Message Format IR Command ListTable 6-2 lists the RC5 control codes for the DHD Controller. S1S2TBA4A3A2A1A0C5C4C3C2C1C0 Start Bits Toggle BitAddress Bits Command Bits 110100 01000001 14 cycles, 24.9 ms 64 cycles, 113.8 ms First Packet Repeated Packet Data Word Encoded Data Word Modulated Carrier Zoom In of Carrier RC5 Packet Transmission3t p tp 1.78 ms 27.8 µs Table 6-2. RC5 Control Codes for the DHD Controller Remote Control Button Name RC5 Data from Remote Control (Note)RC5 Data with Toggle Bit = 1 (Note) Description (none)0x346E0x3C6ENative aspect ratio (none)0x34570x3C57SCART video input 16:90x34490x3C4916:9 aspect ratio 4:30x344A0x3C4A4:3 aspect ratio CINEMA0x346C0x3C6CCinema aspect ratio COMP0x344E0x3C4EComponent video input Note: These codes assume that the default address of 17 is used. If you change it to something other than 17, you will need to modify these codes accordingly.
External Control 70 PlasmaWall XP Series Installation/Operation Manual PRELI MINARY CUST 10x34720x3C72Custom 1 memory preset CUST 20x34730x3C73Custom 2 memory preset DOWN0x34460x3C46Down-Arrow () ENTER0x34440x3C44ENTER EXIT0x34740x3C74EXIT (RETURN) HD 10x34510x3C51HD1 video input HD 20x34520x3C52HD2 video input HDMI 10x34530x3C53HDMI1 video input HDMI 20x34540x3C54HDMI2 video input ISF DAY0x34710x3C71ISF Day memory preset ISF NIGHT0x34700x3C70ISF Night memory preset LEFT0x34470x3C47Left-Arrow () LET BOX0x344B0x3C4BLetterbox aspect ratio MENU0x34430x3C43MENU OFF0x34420x3C42Power off ON0x34410x3C41Power on RIGHT0x34480x3C48Right-Arrow () SVC0x346D0x3C6DVirtual Cinema aspect ratio S-VID 10x344F0x3C4FS-Video 1 video input S-VID 20x34500x3C50S-Video 2 video input UP0x34450x3C45Up-Arrow () VIDEO0x344D0x3C4DComposite video input V-WIDE0x344C0x3C4CVirtualWide aspect ratio Table 6-2. RC5 Control Codes for the DHD Controller (continued) Remote Control Button NameRC5 Data from Remote Control (Note)RC5 Data with Toggle Bit = 1 (Note)Description Note: These codes assume that the default address of 17 is used. If you change it to something other than 17, you will need to modify these codes accordingly.
PlasmaWall XP Series Installation/Operation Manual 71 PREL IMINARY 7.1 PlasmaWall Specifications Table 7-1 lists the PlasmaWall specifications. 7. Specifications Table 7-1. PlasmaWall Specifications Native Resolution:1920 x 1080 Screen Size: XP-50DHD and XP-OPAL50DHD: 43.50 in. W x 24.50 in. H (1104.9 x 622.3 mm) 50 in. (1270.0 mm) diagonal XP-65DHD and XP-OPAL65DHD: 56.50 in. W x 31.80 in. H (1434.0 x 807.0 mm) 65 in. (1646.0 mm) diagonal XP-103DHD: 89.30 in. W x 50.30 in. H (2268.2 x 1277.6 mm) 103 in. (2616.2 mm) diagonal Screen Aspect Ratio:16:9 Available Aspect Ratios:Refer to Table 7-2 DTV Compatibility:480p, 720p, 1080i, 1080p Contrast Ratio:400:1 (measured at 100 lux); 5,000:1 maximum Data/Graphics Compatibility:VGA, SVGA, XGA, SXGA, UXGA (compressed) Horiz. scan frequency = 15 to 110 kHz Vert. scan frequency = 48 to 120 Hz Inputs (from DHD Controller):(1) Digital Video (HDMI 1.2A with HDCP) (1) RS-232 (9-pin, D-sub male) Power Requirements:XP-50DHD / XP-OPAL50DHD / XP-65DHD / XP-OPAL65DHD: 100 to 240 VAC, 50/60Hz XP-103DHD: 200 to 240 VAC, 50/60Hz Power Consumption:XP-50DHD / XP-OPAL50DHD: 650 W (1.0 W in standby), maximum XP-65DHD / XP-OPAL65DHD: 790 W (1.0 W in standby), maximum XP-103DHD: 1500 W (1.5 W in standby), maximum Operating Environment:40ºF to 95ºF (5ºC to 35ºC); 20% to 80% humidity (non-condensing) Altitude – up to 9,000 feet (2,743m) Dimensions:XP-50DHD / XP-OPAL50DHD: See Figure 7-1 XP-65DHD / XP-OPAL65DHD: See Figure 7-2 XP-103DHD: See Figure 7-3 Weight (panel only, without stand): XP-50DHD / XP-OPAL50DHD: 93.0 lbs. (42.18 kg) XP-65DHD / XP-OPAL65DHD: 163.1 lbs. (73.98 kg) XP-103DHD: 485.0 lbs. (220.0 kg) Regulatory Approvals:Complies with FCC Part 15 Class B, ICES-003, UL6500 Ver.2 Specifications are subject to change without notice.
Specifications 72 PlasmaWall XP Series Installation/Operation Manual PREL IMINARY 7.2 DHD Controller Specifications Table 7-2 lists the DHD Controller specifications. Table 7-2. DHD Controller Specifications Aspect Ratios: 4:3, Letterbox, 16:9, VirtualWide, Cinema, Virtual Cinema, Native Video Standards:NTSC, PAL, SECAM Inputs: (1) Composite (2) S-Video (1) Component/RGBHV/SCART (5 x RCA) (2) Component/RGBHV (5 x BNC) (2) HDMI 1.3 with HDCP Outputs: HDMI 1.3 with HDCP Control Options:- Discrete infrared remote - Serial commands via RS-232 - Front-panel controls RS-232 Communication Parameters: 19200 bps, no parity, 8 data bits, 1 stop bit, no flow control Trigger Outputs: (3) +12 VDC, each rated at 250 mA and thermal fuse-protected Bandwidth:150 Mega Samples per Second (MSPS) Power Requirements: 100 to 240 VAC (auto-sensing), 50/60 Hz, 160 Watts Operating Environment:41°F to 95°F (5°C to 35°C), 0% to 90% humidity (non-condensing) Dimensions:Width = 17.50 inches (444.5 mm) Depth = 11.19 inches (284.1 mm) Height = 3.75 inches (95.3 mm) Weight: 13.0 lbs. (5.90 kg) Regulatory Approvals:Complies with FCC, CE C-Tick Limited Warranty: Two (2) years parts and labor from the date of delivery to the end user. Specifications are subject to change without notice.
Specifications PlasmaWall XP Series Installation/Operation Manual 73 PREL IMINARY 7.3 PlasmaWall Dimensions Figure 7-1, Figure 7-2 and Figure 7-3 show the PlasmaWall dimensions (all dimensions are in inches). Figure 7-1. PlasmaWall Model XP-50DHD and XP-OPAL50DHD Dimensions (with Optional Table Stand) 30.000 50.42034.000 8.122 4.5663.490 15.5000 8.481 10.23014.387 16.13620.29322.042 22.82830.00048.807 29.574
Specifications 74 PlasmaWall XP Series Installation/Operation Manual PREL IMINARY Figure 7-2. PlasmaWall Model XP-65DHD and XP-OPAL65DHD Dimensions (with Optional Table Stand) 0 7.87 12.371.98 2.35 3.69 62.45 54.60 50.10 0 1.63 37.69 1.34 IR RECEIVER 1.262.49 all around 17.00 0 4.34 8.27 .55 54.19 58.12 61.90 62.45 6.39 4.1910.05 2.07 1.504.506.19 1.73