Home > Runco > Display > Runco XP-50DHD Plasma Display User Manual

Runco XP-50DHD Plasma Display User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Runco XP-50DHD Plasma Display User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 123 Runco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							External Control
    PlasmaWall XP Series Installation/Operation Manual 65 
    PREL
    IMINARY
    Aspect Ratio Commands
    16:9NAYESSelects the 16:9 aspect ratio
    4:3NAYESSelects the 4:3 aspect ratio
    ASPECT?NANAReturns current aspect ratio
    CINEMANAYESSelects the Cinema aspect ratio
    LETTERBOXNAYESSelects the Letterbox aspect ratio
    NATIVENAYESSelects the Native aspect ratio
    VIRTUALWIDENAYESSelects the VirtualWide aspect ratio
    VIRTUALCINEMANAYESSelects the Virtual Cinema aspect ratio
    Picture Adjust Commands
    BRIGHTNESS-50/50YESSets a value for brightness
    BRIGHTNESS?NANAReturns brightness setting value
    CHROMADELAY-7/7YESSets a value for input color chroma delay
    CHROMADELAY?NANAReturns input color chroma delay setting
    COLOR-50/50YESSets a value for color
    COLOR?NANAReturns color setting value
    CONTRAST-50/50YESSets a value for contrast
    CONTRAST?NANAReturns contrast setting value
    FILMMODE0/1YESSets Film Mode off (0) or on (1)
    FILMMODE?NANAReturns Film Mode setting 
    (0 = off; 1 = on)
    FILTER0/10YESSets a value for input color noise filter
    FILTER?NANAReturns input color noise filter setting
    PHASE0/31YESAdjusts phase
    PHASE?NANAReturns phase setting value
    SHARPNESS-50/50YESSets a value for sharpness
    SHARPNESS?NANAReturns sharpness setting value
    TINT-50/50YESSets a value for tint
    TINT?NANAReturns tint setting value
    Table 6-1. Serial Commands (continued)
    CommandParameter 
    (min/max)Value 
    Stored?Description 
    						
    							External Control
    66 PlasmaWall XP Series Installation/Operation Manual
    PRELI
    MINARY
    Image Preset Commands
    CUSTOM1NAYESLoads “Custom 1” image preset
    CUSTOM2NAYESLoads “Custom 2” (“THX”) image preset
    DAYNAYESLoads “ISF Day” image preset
    NIGHTNAYESLoads “ISF Night” image preset
    PRESET?NANAReturns currently-selected preset 
    (ISF Day, ISF Night, Custom 1 or 
    Custom
     2/THX)
    Input Position Commands
    IHEIGHT0/20YESSets the value for input height
    IHEIGHT?NANAReturns input height value
    IHPOS-50/50YESSets a value for horizontal input position
    IHPOS?NANAReturns input horizontal position value
    IVPOS-50/50YESSets a value for vertical input position
    IVPOS?NANAReturns input vertical position value
    IWIDTH0/50YESSets the value for input width 
    IWIDTH?NANAReturns input horizontal width value
    OVERSCAN 0/20YESSets the overscan percentage
    OVERSCAN?NANAReturns overscan percentage
    OVERSCANMODE 0/1YESSets the overscan mode (0=zoom; 
    1=crop)
    OVERSCANMODE?NANAReturns the overscan mode (0=zoom; 
    1=crop)
    Output Shift Commands
    OHEIGHT-50/50YESSets the value for output height
    OHEIGHT?NANAReturns output height value
    OHPOS-50/50YESSets the value for output horizontal posi-
    tion
    OHPOS?NANAReturns output horizontal position value
    OVPOS-50/50YESSets the value for output vertical position 
    OVPOS?NANAReturns output vertical position value
    OWIDTH-50/50YESSets the value for output width
    OWIDTH?NANAReturns output horizontal width value
    Table 6-1. Serial Commands (continued)
    CommandParameter 
    (min/max)Value 
    Stored?Description 
    						
    							External Control
    PlasmaWall XP Series Installation/Operation Manual 67 
    PREL
    IMINARY
    Miscellaneous Commands
    DISPLAY?NANAReturns display device input source 
    value, as follows:
    1 = Auto
    22 = XP-50DHD
    23 = XP-65DHD
    24 = XP-103DHD
    INRES?NANAReturns input resolution
    MODEL?NANAReturns product model name
    OUTRES?NANAReturns output resolution
    SERNUM?NANAReturns DHD Controller serial number
    SWVER?NANAReturns software version number
    SYSSTATE?0/4NAReturns current system state
    0 = Off
    1 = Initializing
    2 = On
    3 = Powering Down
    4 = Error
    TRIGGER1/3YESAssigns trigger to currently-selected 
    aspect ratio
    The following serial commands are meant to emulate buttons on the remote control or DHD Con-
    troller front panel. Each button has its own serial command, so effectively it is as if you were using 
    the IR remote only you’ll be doing so via serial commands. These commands provide active OSD 
    responses just like the IR remote. 
    DOWNNANADown-Arrow () key
    ENTERNANAENTER key
    EXITNANAEXIT (RETURN) key
    LEFTNANALeft-Arrow () key
    MENUNANAMENU
    RIGHTNANARight-Arrow () key
    UPNANAUp-Arrow () key
    Table 6-1. Serial Commands (continued)
    CommandParameter 
    (min/max)Value 
    Stored?Description 
    						
    							External Control
    68 PlasmaWall XP Series Installation/Operation Manual
    PRELI
    MINARY
    6.2 
    Using Discrete IR 
    Codes
    The DHD Controller accepts commands in the form of IR signals that conform to the 
    Phillips RC5 protocol. Each DHD Controller remote control button has an RC5 control 
    code associated with it. 
    You can use these codes to program a third-party, “universal” remote control unit to work 
    with the DHD Controller. These third-party products usually come with a computer 
    software application for this purpose. For more information, consult the documentation 
    provided with the remote control unit. 
    IR Command ProtocolThe IR control codes have the following characteristics:
     Each code consists of 14 bits:
     Two (2) start bits (always 1);
    A toggle bit. This bit is inverted every time a key is released and pressed again. This 
    allows the DHD Controller to distinguish between a button that remains down or is 
    pressed repeatedly.
     Five (5) address bits. The default address is 17 (binary 10001). To change it, select 
    Remote Control from the Service menu and follow the steps given on page 54. 
     Six (6) data bits. 
     The carrier frequency is 36 kHz, with the modulated pulses having a 25% duty cycle. 
     Commands are sent at a maximum rate of 9 Hz.
    For example, here is the RC5 control code for the ON button on the DHD Controller 
    remote control unit (assuming the default address is used): 
     
    ➤
    With Toggle Bit = 0
    Hex3441
    Binary11010001000001
    With Toggle Bit = 1
    Hex3C41
    Binary11110001000001
    FunctionStart 
    BitsToggle 
    BitAddressCommand 
    						
    							External Control
    PlasmaWall XP Series Installation/Operation Manual 69 
    PREL
    IMINARY
    Figure 6-1 shows the pulse train for this command (with the toggle bit set to zero). 
    Figure 6-1. RC5 Message Format
    IR Command ListTable 6-2 lists the RC5 control codes for the DHD Controller. 
    S1S2TBA4A3A2A1A0C5C4C3C2C1C0
    Start Bits Toggle BitAddress Bits Command Bits
    110100 01000001
    14 cycles, 24.9 ms
    64 cycles,  113.8 ms First Packet Repeated Packet
    Data
    Word
    Encoded
    Data
    Word
    Modulated
    Carrier
    Zoom In
    of Carrier
    RC5 Packet
    Transmission3t
    p
    tp
    1.78 ms
    27.8 µs
    Table 6-2. RC5 Control Codes for the DHD Controller 
    Remote Control 
    Button Name
    RC5 Data 
    from 
    Remote 
    Control 
    (Note)RC5 Data 
    with Toggle 
    Bit = 1 
    (Note)
    Description
    (none)0x346E0x3C6ENative aspect ratio
    (none)0x34570x3C57SCART video input
    16:90x34490x3C4916:9 aspect ratio
    4:30x344A0x3C4A4:3 aspect ratio
    CINEMA0x346C0x3C6CCinema aspect ratio
    COMP0x344E0x3C4EComponent video input
    Note: These codes assume that the default address of 17 is used. If you change it to something 
    other than 17, you will need to modify these codes accordingly.  
    						
    							External Control
    70 PlasmaWall XP Series Installation/Operation Manual
    PRELI
    MINARY
    CUST 10x34720x3C72Custom 1 memory preset
    CUST 20x34730x3C73Custom 2 memory preset
    DOWN0x34460x3C46Down-Arrow ()
    ENTER0x34440x3C44ENTER
    EXIT0x34740x3C74EXIT (RETURN)
    HD 10x34510x3C51HD1 video input
    HD 20x34520x3C52HD2 video input
    HDMI 10x34530x3C53HDMI1 video input
    HDMI 20x34540x3C54HDMI2 video input
    ISF DAY0x34710x3C71ISF Day memory preset
    ISF NIGHT0x34700x3C70ISF Night memory preset
    LEFT0x34470x3C47Left-Arrow ()
    LET BOX0x344B0x3C4BLetterbox aspect ratio
    MENU0x34430x3C43MENU
    OFF0x34420x3C42Power off
    ON0x34410x3C41Power on
    RIGHT0x34480x3C48Right-Arrow ()
    SVC0x346D0x3C6DVirtual Cinema aspect ratio
    S-VID 10x344F0x3C4FS-Video 1 video input
    S-VID 20x34500x3C50S-Video 2 video input
    UP0x34450x3C45Up-Arrow ()
    VIDEO0x344D0x3C4DComposite video input
    V-WIDE0x344C0x3C4CVirtualWide aspect ratio
    Table 6-2. RC5 Control Codes for the DHD Controller (continued)
    Remote Control 
    Button NameRC5 Data 
    from 
    Remote 
    Control 
    (Note)RC5 Data 
    with Toggle 
    Bit = 1 
    (Note)Description
    Note: These codes assume that the default address of 17 is used. If you change it to something 
    other than 17, you will need to modify these codes accordingly.  
    						
    							PlasmaWall XP Series Installation/Operation Manual 71 
    PREL
    IMINARY
    7.1 
    PlasmaWall 
    Specifications
    Table 7-1 lists the PlasmaWall specifications.  
    7. Specifications
    Table 7-1. PlasmaWall Specifications 
    Native Resolution:1920 x 1080
    Screen Size:  XP-50DHD and XP-OPAL50DHD: 
    43.50 in. W x 24.50 in. H (1104.9 x 622.3 mm)
    50 in. (1270.0 mm) diagonal
    XP-65DHD and XP-OPAL65DHD: 
    56.50 in. W x 31.80 in. H (1434.0 x 807.0 mm)
    65 in. (1646.0 mm) diagonal
    XP-103DHD: 
    89.30 in. W x 50.30 in. H (2268.2 x 1277.6 mm)
    103 in. (2616.2 mm) diagonal
    Screen Aspect Ratio:16:9
    Available Aspect Ratios:Refer to Table 7-2
    DTV Compatibility:480p, 720p, 1080i, 1080p
    Contrast Ratio:400:1 (measured at 100 lux); 5,000:1 maximum
    Data/Graphics Compatibility:VGA, SVGA, XGA, SXGA, UXGA (compressed)
    Horiz. scan frequency = 15 to 110 kHz
    Vert. scan frequency = 48 to 120 Hz
    Inputs (from DHD Controller):(1) Digital Video (HDMI 1.2A with HDCP) 
    (1) RS-232 (9-pin, D-sub male) 
    Power Requirements:XP-50DHD / XP-OPAL50DHD / XP-65DHD / 
    XP-OPAL65DHD: 100 to 240 VAC, 50/60Hz
    XP-103DHD: 200 to 240 VAC, 50/60Hz
    Power Consumption:XP-50DHD / XP-OPAL50DHD: 650 W (1.0 W in standby), 
    maximum
    XP-65DHD / XP-OPAL65DHD: 790 W (1.0 W in standby), 
    maximum
    XP-103DHD: 1500 W (1.5 W in standby), maximum
    Operating Environment:40ºF to 95ºF (5ºC to 35ºC); 
    20% to 80% humidity (non-condensing)
    Altitude – up to 9,000 feet (2,743m) 
    Dimensions:XP-50DHD / XP-OPAL50DHD: See Figure 7-1
    XP-65DHD / XP-OPAL65DHD: See Figure 7-2
    XP-103DHD: See Figure 7-3
    Weight 
    (panel only, without stand): XP-50DHD / XP-OPAL50DHD: 93.0 lbs. (42.18 kg) 
    XP-65DHD / XP-OPAL65DHD: 163.1 lbs. (73.98 kg) 
    XP-103DHD: 485.0 lbs. (220.0 kg) 
    Regulatory Approvals:Complies with FCC Part 15 Class B, ICES-003, UL6500 
    Ver.2
    Specifications are subject to change without notice.  
    						
    							Specifications
    72 PlasmaWall XP Series Installation/Operation Manual
    PREL
    IMINARY
    7.2 
    DHD Controller 
    Specifications
    Table 7-2 lists the DHD Controller specifications.  
    Table 7-2. DHD Controller Specifications 
    Aspect Ratios: 4:3, Letterbox, 16:9, VirtualWide, Cinema, Virtual Cinema, 
    Native
    Video Standards:NTSC, PAL, SECAM
    Inputs: (1) Composite
    (2) S-Video
    (1) Component/RGBHV/SCART (5 x RCA)
    (2) Component/RGBHV (5 x BNC)
    (2) HDMI 1.3 with HDCP
    Outputs: HDMI 1.3 with HDCP
    Control Options:- Discrete infrared remote
    - Serial commands via RS-232
    - Front-panel controls 
    RS-232 Communication 
    Parameters: 19200 bps, no parity, 8 data bits, 1 stop bit, no flow control
    Trigger Outputs: (3) +12 VDC, each rated at 250 mA and thermal 
    fuse-protected 
    Bandwidth:150 Mega Samples per Second (MSPS)
    Power Requirements: 100 to 240 VAC (auto-sensing), 50/60 Hz, 160 Watts
    Operating Environment:41°F to 95°F (5°C to 35°C), 0% to 90% humidity 
    (non-condensing) 
    Dimensions:Width = 17.50 inches (444.5 mm)
    Depth = 11.19 inches (284.1 mm)
    Height = 3.75 inches (95.3 mm)
    Weight: 13.0 lbs. (5.90 kg)
    Regulatory Approvals:Complies with FCC, CE C-Tick
    Limited Warranty: Two (2) years parts and labor from the date of delivery to 
    the end user.
    Specifications are subject to change without notice.  
    						
    							Specifications
    PlasmaWall XP Series Installation/Operation Manual 73 
    PREL
    IMINARY
    7.3 
    PlasmaWall 
    Dimensions
    Figure 7-1, Figure 7-2 and Figure 7-3 show the PlasmaWall dimensions (all dimensions 
    are in inches).
     
    Figure 7-1. PlasmaWall Model XP-50DHD and XP-OPAL50DHD Dimensions (with 
    Optional Table Stand)
    30.000 50.42034.000
    8.122 4.5663.490
    15.5000 8.481 10.23014.387 16.13620.29322.042 22.82830.00048.807
    29.574 
    						
    							Specifications
    74 PlasmaWall XP Series Installation/Operation Manual
    PREL
    IMINARY
     
    Figure 7-2. PlasmaWall Model XP-65DHD and XP-OPAL65DHD Dimensions (with 
    Optional Table Stand)
    0
    7.87
    12.371.98
    2.35
    3.69
    62.45 54.60 50.10
    0
    1.63 37.69
    1.34
     IR RECEIVER
    1.262.49
    all around 17.00
    0
    4.34
    8.27 .55
    54.19
    58.12
    61.90
    62.45
    6.39
    4.1910.05
    2.07
    1.504.506.19 1.73 
    						
    All Runco manuals Comments (0)