Page 41
Operation CinemaWall XP-50/XP-65 Installation/Operation Manual 27 PREL IMINARY Selecting a PIP Target Screen or Input Source Press SELECT () to choose a target screen (main or sub) for PIP operations. The audio signal associated with the target screen is heard through the speakers. Press INPUT () to select an input to display on the target screen (main or sub). Changing the PIP Window Position To change the PIP window position, press MOVE/ZOOM ( ) repeatedly until the window is in the desired...
Page 42
Operation 28 CinemaWall XP-50/XP-65 Installation/Operation Manual PREL IMINARY The OSD menu closes after 60 seconds of inactivity. The CinemaWall OSD menus are arranged hierarchically, as shown in Figure 4-1. Depending on the selected input source and signal characteristics, some menu options may not be available. Figure 4-1. OSD Menu Structure for CinemaWall POS./SIZE H-POS -124, -123 ... 0 ... 123, 124 H-SIZE V-POS V-SIZE -62, -61 ... 0 ... 61, 62 DOT CLOCK (INPUT3/PC INPUT only)-32, -31 ... 0 ......
Page 43
Operation CinemaWall XP-50/XP-65 Installation/Operation Manual 29 PREL IMINARY Figure 4-1. OSD Menu Structure for CinemaWall (continued) SET UP (2/2) MULTI DISPLAY SETUP (Note: Must set MULTI PIP SETUP -> DISPLAY MODE to “-” (normal)MULTI DISPLAY SETUP ON/OFF HORIZONTAL SCALE x2, x3, x4 or x5 VERTICAL SCALE x1, x2, x3, x4 or x5 SEAM HIDES VIDEO ON/OFF LOCATION A1, A2, A3, A4, A5, B1, B2 ... E3, E4, E5 AI SYNCHRONIZATION ON/OFF MULTI PIP SETUPMULTI PIP PIP, ADVANCED PIP, BLEND PIP DISPLAY MODEMULTI PIP...
Page 44
Operation 30 CinemaWall XP-50/XP-65 Installation/Operation Manual PREL IMINARY PICTUREUse the controls in the PICTURE menu to calibrate your CinemaWall for optimum picture quality. The CinemaWall has been designed to incorporate setup and calibration standards established by the Imaging Science Foundation (ISF). The ISF has developed carefully crafted, industry-recognized standards for optimal video performance and has implemented a training program for technicians and installers to use these...
Page 45
Operation CinemaWall XP-50/XP-65 Installation/Operation Manual 31 PREL IMINARY PICTURE MENU: The CinemaWall provides four picture memories per input for storing and recalling image quality settings. To store settings in a picture memory, highlight PICTURE MENU in the PICTURE menu and select STANDARD, ISF DAY, ISF NIGHT or MONITOR. The CinemaWall “remembers” any adjustments you make when you switch to a different picture memory, then switch back. PICTURE: On your external test pattern source, select...
Page 46
Operation 32 CinemaWall XP-50/XP-65 Installation/Operation Manual PREL IMINARY BRIGHTNESS: On your external test pattern source, select a PLUGE pattern. (PLUGE is an acronym for “Picture Line-Up Generation Equipment.”) Figure 4-3 shows a typical PLUGE pattern. Figure 4-3. Typical PLUGE Pattern for Adjusting Brightness PLUGE patterns vary but generally consist of some combination of black, white and gray areas against a black background. The example above includes two vertical bars and four shaded...
Page 47
Operation CinemaWall XP-50/XP-65 Installation/Operation Manual 33 PREL IMINARY COLOR: On your external test pattern source, select a color bar pattern like the one shown in Figure 4-4. Figure 4-4. Typical Color Bar Pattern for Adjusting Color Saturation and Tint Select COLOR from the PICTURE menu. While looking at the color bar pattern through a blue filter, adjust the color saturation level until the outermost (gray and blue) color bars appear to be a single shade of blue: TINT: Tint or “hue” is...
Page 48
Operation 34 CinemaWall XP-50/XP-65 Installation/Operation Manual PREL IMINARY SHARPNESS: “Sharpness” is the amount of high-frequency detail in the image. To adjust sharpness, select SHARPNESS from the PICTURE menu. On your external test pattern source, select a pattern like the one shown in Figure 4-5. Adjust as needed, looking for white edges around the transitions from black to gray and different sized lines in the “sweep” patterns at the top and bottom. Lower the sharpness setting to eliminate...
Page 49
Operation CinemaWall XP-50/XP-65 Installation/Operation Manual 35 PREL IMINARY GAMMA: The default gamma setting (2.2) is correct for almost all signals and conditions. If excess ambient light washes out the image and it becomes difficult or impossible to see details in dark areas, lower the gamma setting to compensate. This will improve contrast while maintaining good details for blacks. Conversely, if the image is washed out and unnatural, with excessive detail in black areas, increase the setting....
Page 50
Operation 36 CinemaWall XP-50/XP-65 Installation/Operation Manual PREL IMINARY AUTO SETUP (PC INPUT only): To automatically adjust the position, size, clock and phase of incoming computer signals for optimum picture quality, press or repeatedly to highlight AUTO SETUP in the menu, then press the ACTION () button. H-POS/V-POS: Select H-POS or V-POS and use the or buttons to fine-tune the displayed image position. H-SIZE/V-SIZE: Select H-SIZE or V-SIZE and use the or buttons to fine-tune the...