Home > Runco > Television > Runco Television XP-65 User Manual

Runco Television XP-65 User Manual

Here you can view all the pages of manual Runco Television XP-65 User Manual. The Runco manuals for Television are available online for free. You can easily download all the documents as PDF.

Page 41

Operation
CinemaWall XP-50/XP-65 Installation/Operation Manual 27 
PREL
IMINARY
Selecting a PIP Target 
Screen or Input Source
Press SELECT () to choose a target 
screen (main or sub) for PIP operations.
The audio signal associated with the target 
screen is heard through the speakers.
Press INPUT () to select an input to 
display on the target screen (main or sub).
Changing the PIP Window 
Position
To change the PIP window position, press 
MOVE/ZOOM (
) repeatedly until the window is in 
the desired...

Page 42

Operation
28 CinemaWall XP-50/XP-65 Installation/Operation Manual
PREL
IMINARY
 The OSD menu closes after 60 seconds of inactivity. 
The CinemaWall OSD menus are arranged hierarchically, as shown in Figure 4-1. 
Depending on the selected input source and signal characteristics, some menu options 
may not be available. 
Figure 4-1. OSD Menu Structure for CinemaWall
POS./SIZE
H-POS
-124, -123 ... 0 ... 123, 124 H-SIZE
V-POS
V-SIZE -62, -61 ... 0 ... 61, 62
DOT CLOCK
(INPUT3/PC INPUT only)-32, -31 ... 0 ......

Page 43

Operation
CinemaWall XP-50/XP-65 Installation/Operation Manual 29 
PREL
IMINARY
Figure 4-1. OSD Menu Structure for CinemaWall (continued)
SET UP
(2/2)
MULTI DISPLAY SETUP
(Note: Must set 
MULTI PIP SETUP -> DISPLAY 
MODE to “-” (normal)MULTI DISPLAY SETUP ON/OFF
HORIZONTAL SCALE x2, x3, x4 or x5
VERTICAL SCALE x1, x2, x3, x4 or x5
SEAM HIDES VIDEO ON/OFF
LOCATION A1, A2, A3, A4, A5, B1, B2 ... E3, E4, E5
AI SYNCHRONIZATION ON/OFF
MULTI PIP SETUPMULTI PIP PIP, ADVANCED PIP, BLEND PIP
DISPLAY MODEMULTI PIP...

Page 44

Operation
30 CinemaWall XP-50/XP-65 Installation/Operation Manual
PREL
IMINARY
PICTUREUse the controls in the PICTURE menu to calibrate your CinemaWall for optimum picture 
quality.
The CinemaWall has been designed to incorporate setup and calibration standards 
established by the Imaging Science Foundation (ISF). The ISF has developed carefully 
crafted, industry-recognized standards for optimal video performance and has 
implemented a training program for technicians and installers to use these...

Page 45

Operation
CinemaWall XP-50/XP-65 Installation/Operation Manual 31 
PREL
IMINARY
PICTURE MENU: The CinemaWall provides four picture memories per input for storing 
and recalling image quality settings. To store settings in a picture memory, highlight 
PICTURE MENU in the PICTURE menu and select STANDARD, ISF DAY, ISF NIGHT or 
MONITOR. The CinemaWall “remembers” any adjustments you make when you switch to 
a different picture memory, then switch back. 
PICTURE: On your external test pattern source, select...

Page 46

Operation
32 CinemaWall XP-50/XP-65 Installation/Operation Manual
PREL
IMINARY
BRIGHTNESS: On your external test pattern source, select a PLUGE pattern. (PLUGE is 
an acronym for “Picture Line-Up Generation Equipment.”) 
Figure 4-3 shows a typical 
PLUGE pattern.
Figure 4-3. Typical PLUGE Pattern for Adjusting Brightness
PLUGE patterns vary but generally consist of some combination of black, white and gray 
areas against a black background. The example above includes two vertical bars and four 
shaded...

Page 47

Operation
CinemaWall XP-50/XP-65 Installation/Operation Manual 33 
PREL
IMINARY
COLOR: On your external test pattern source, select a color bar pattern like the one 
shown in 
Figure 4-4. 
Figure 4-4. Typical Color Bar Pattern for Adjusting Color Saturation and Tint
Select COLOR from the PICTURE menu. While looking at the color bar pattern through a 
blue filter, adjust the color saturation level until the outermost (gray and blue) color bars 
appear to be a single shade of blue: 
TINT: Tint or “hue” is...

Page 48

Operation
34 CinemaWall XP-50/XP-65 Installation/Operation Manual
PREL
IMINARY
SHARPNESS: “Sharpness” is the amount of high-frequency detail in the image. To adjust 
sharpness, select 
SHARPNESS from the PICTURE menu. On your external test pattern 
source, select a pattern like the one shown in Figure 4-5. Adjust as needed, looking for 
white edges around the transitions from black to gray and different sized lines in the 
“sweep” patterns at the top and bottom. Lower the sharpness setting to eliminate...

Page 49

Operation
CinemaWall XP-50/XP-65 Installation/Operation Manual 35 
PREL
IMINARY
GAMMA: The default gamma setting (2.2) is correct for almost all signals and 
conditions. If excess ambient light washes out the image and it becomes difficult or 
impossible to see details in dark areas, lower the gamma setting to compensate. This 
will improve contrast while maintaining good details for blacks. Conversely, if the image 
is washed out and unnatural, with excessive detail in black areas, increase the setting....

Page 50

Operation
36 CinemaWall XP-50/XP-65 Installation/Operation Manual
PREL
IMINARY
AUTO SETUP (PC INPUT only): To automatically adjust the position, size, clock and 
phase of incoming computer signals for optimum picture quality, press 
 or  repeatedly 
to highlight AUTO SETUP in the menu, then press the ACTION () button. 
H-POS/V-POS: Select H-POS or V-POS and use the  or  buttons to fine-tune the 
displayed image position.
H-SIZE/V-SIZE: Select H-SIZE or V-SIZE and use the  or  buttons to fine-tune the...
Start reading Runco Television XP-65 User Manual

Related Manuals for Runco Television XP-65 User Manual

All Runco manuals