Home > Ricoh > Camera > Ricoh Kr5 Instruction Manual

Ricoh Kr5 Instruction Manual

Here you can view all the pages of manual Ricoh Kr5 Instruction Manual. The Ricoh manuals for Camera are available online for free. You can easily download all the documents as PDF.

Page 311

309
Appendix11 [A Custom Setting] Menu
*1 The adjustment values are reset only for [Reset] in the [21. AF Fine Adjustment] screen.
ItemDefault SettingReset 
SettingPage
1. EV Steps 1/3 EV Steps Yes p.118
2. Sensitivity Steps 1 EV Step Yes p.99
3. Expanded Sensitivity Off Yes p.99
4. Meter Operating Time 10 sec. Yes p.116
5. AE-L with AF Locked Off Yes p.133
6. Link AE to AF Point Off Yes p.115
7. Auto Bracketing Order 0 - + Yes p.118
8. Superimpose AF Area On Yes p.130
9. AF.S Setting Focus-priority Yes...

Page 312

310
Appendix11
Resetting the Menus
Settings in the [ARec. Mode] menu, [QPlayback] menu, [RSet-up] 
menu, direct keys and playback mode palette can be reset to default 
settings.
1Select [Reset] in the [R Set-up 3] menu and press the four-
way controller (5).
The [Reset] screen appears.
2Press the four-way controller (2) 
to select [Reset] and press the 
4 button.
The settings are reset, and the screen 
that was displayed before selecting the 
menu appears again.
Resetting the Rec. Mode/Playback/Set-up...

Page 313

311
Appendix11 Reset settings in [ACustom Setting] menu to default values.
1Select [Reset Custom Functions] in the [ACustom 
Setting 4] menu and press the four-way controller (5).
The [Reset Custom Functions] screen appears.
2Press the four-way controller (2) 
to select [Reset] and press the 
4 button.
The settings are reset, and the screen 
that was displayed before selecting the 
menu appears again.
Resetting the Custom Menu
Reset Custom Functions
CancelReset Returns the custom function
settings to...

Page 314

312
Appendix11
Functions Available with Various 
Lens Combinations
Only DA, DA L and FA J lenses and D FA/FA/F/A lenses which have an s 
(Auto) position on the aperture ring can be used with factory default 
settings. Refer to “Notes on [22. Using Aperture Ring]” (p.314) for other 
lenses and D FA/FA/F/A lenses with aperture ring set to a position other 
than s.
z : Functions are available when the aperture ring is set to the s position.
# : Some functions are restricted.
× : Functions are unavailable....

Page 315

313
Appendix11
*1 Lenses with a maximum aperture of F2.8 or faster. Only available at the s position.
*2 Lenses with a maximum aperture of F5.6 or faster.
*3 When using the built-in flash and AF540FGZ, AF360FGZ, AF200FG or AF160FC.
*4 Aberration correction is available in [Lens Correction] of the [A Rec. Mode 3] menu. The 
[Distortion Correction] setting is disabled when using a DA 10-17mm FISH-EYE lens.
*5 Only available with compatible lenses.
*6 To use an FA/F SOFT 85 mm F2.8 lens or FA SOFT 28 mm...

Page 316

314
Appendix11When [22. Using Aperture Ring] is set to 
[Permitted] in the [ACustom Setting 4] 
menu, the shutter can be released even if the 
aperture ring of the D FA, FA, F or A lens is 
not set to the s (Auto) position or a lens 
without an s position is attached. However, 
some features will be restricted as shown 
below.
Restrictions on using lenses with aperture ring set to a position other than s
Notes on [22. Using Aperture Ring]
Lens UsedExposure 
ModeRestriction
D FA, FA, F, A, M (lens 
only...

Page 317

315
Appendix11
Cleaning the CMOS Sensor
If the CMOS sensor becomes dirty or dusty, shadows may appear in the 
image in certain situations such as when shooting against a white 
background. This indicates that the CMOS sensor must be cleaned.
Shaking the CMOS sensor removes dust that has collected.
1Select [Dust Removal] in the [RSet-up 4] menu and press 
the four-way controller (5).
The [Dust Removal] screen appears.
2Press the 4 button.
The Dust Removal function is activated 
by shaking the CMOS...

Page 318

316
Appendix11Dust Alert is a function that detects dust adhering to the CMOS sensor and 
visually displays the location of the dust.
You can save an image indicating the dust location and display it when 
performing sensor cleaning (p.318).
The following conditions must be met before using the Dust Alert function:
- A DA, DA L, FA J lens or a D FA, FA or F lens that has an s (Auto) 
position is attached.
- The aperture is set to the s position when using a lens with an 
aperture ring.
- The mode dial is...

Page 319

317
Appendix11
2Fully display a white wall or other 
bright subject with no detail in 
the viewfinder and press the 
shutter release button fully.
After image processing is performed, the 
Dust Alert image appears.
If the message [The operation could not 
be completed correctly] is displayed, 
press the 4 button and take another picture.
3Check the sensor for dust.
Available operations
4Press the 4 button.
The Dust Alert image is saved and the camera returns to the [R Set-up 
4] menu.
E-dial/
M...

Page 320

318
Appendix11Raise the mirror up and open the shutter when cleaning the CMOS sensor 
with a blower.
Please contact a PENTAX Service Center for professional cleaning 
because the CMOS sensor is a precision part. Cleaning services involve 
a fee.
You can use the optional Imagesensor Cleaning kit O-ICK1 (p.324) when 
cleaning the CMOS sensor.
1Turn the camera off and remove the lens.
2Turn the camera on.
3Select [Sensor Cleaning] in the [RSet-up 4] menu and 
press the four-way controller (5).
The [Sensor...
Start reading Ricoh Kr5 Instruction Manual