Ricoh B230 Service Manual
Here you can view all the pages of manual Ricoh B230 Service Manual. The Ricoh manuals for Printer are available online for free. You can easily download all the documents as PDF.
Page 151
SM 3-23 B230/B237 Replacement Adjustment ƒ SP4–688 (DF: Density Adjustment): Use this to adjust the density level if the ID of outputs made in the DF and Platen mode is different. 3.5.6 EXPOSURE LAMP STABILIZER 1. Rear cover ( Rear Cover) 2. Exposure lamp stabilizer [A] ( x 2, x 2) 3.5.7 FRONT SCANNER WIRE 1. Exposure glass ( Exposure Glass) 2. Front frame ( Exposure Lamp) 3. Front scanner wire clamp [A] 4. Front scanner wire bracket [B] ( x 1) 5. Front scanner wire and...
Page 152
B230/B237 3-24 SM Reinstalling the Front Scanner Wire 1. Position the center ball [A] in the middle of the forked holder. 2. Pass the right end (with the ball) [B] through the square hole. Pass the left end (with the ring) [C] through the notch. 3. Wind the right end counterclockwise (shown from the machine’s front) five times. Wind the left end clockwise twice. ƒ The two red marks [D] come together when you have done this. Stick the wire to the pulley with tape. This lets you easily...
Page 153
SM 3-25 B230/B237 Replacement Adjustment ƒ Do not attach the pulley to the shaft with the screw at this time. 5. Insert the left end into the slit [F]. The end should go via the rear track of the left pulley [G] and the rear track of the movable pulley [H]. 6. Hook the right end onto the front scanner wire bracket [I]. The end should go via the front track of the right pulley [J] and the front track of the movable pulley [K]. ƒ Do not attach the scanner wire bracket with the screw at...
Page 154
B230/B237 3-26 SM the 1st carriage hole [P] and the right holes in the front rail [Q]. 9. Insert two more scanner positioning pins through the holes in the rear rail. 10. Screw the drive pulley to the shaft [R]. 11. Screw the scanner wire bracket to the front rail [S]. 12. Install the scanner wire clamp [T]. 13. Pull out the positioning pins. ƒ Make sure the 1st and 2nd carriages move smoothly after you remove the positioning pins. Do steps 8 through 13 again if they do not. 3.5.8...
Page 155
SM 3-27 B230/B237 Replacement Adjustment be the same as the winding on the three pulleys at the front. This must show as a mirror image. Example: At the front of the machine, the side of the drive pulley with the three windings must face the front of the machine. At the rear of the machine, it must face the rear. 6. Do steps 7 through 13 again in the “” Section. 3.5.9 TOUCH PANEL POSITION ADJUSTMENT ƒ It is necessary to calibrate touch panel at the following times: ƒ When you replace...
Page 156
B230/B237 3-28 SM 8. Touch [#] Exit on the screen to close the Self-Diagnostic menu. Save the calibration settings.
Page 157
SM 3-29 B230/B237 Replacement Adjustment 3.6 LASER OPTICS ƒ Turn off the main switch and unplug the machine before beginning any of the procedures in this section. Laser beams can cause serious eye injury. 3.6.1 CAUTION DECAL LOCATION Caution decals are placed as shown below. ƒ Be sure to turn off the main switch and disconnect the power plug from the power outlet before beginning any disassembly or adjustment of the laser unit. This copier uses a class IIIb laser beam with a...
Page 158
B230/B237 3-30 SM Preparing the new laser optics housing unit 1. Shutter [A] of the laser optics housing unit ( x 3) 2. Polygon motor cover [B] of the laser optics housing unit ( x 4) 3. Sponge padding [C] 4. Tag [D] 5. Reinstall the polygon motor cover [B]. Before removing the old laser optics housing unit Do the following settings before removing the laser optics housing unit. These are adjustments for skew adjustment motors in the laser optics housing unit. 1. Plug in and turn...
Page 159
SM 3-31 B230/B237 Replacement Adjustment 7. Turn off the main power switch and disconnect the power cord of the copier. Recovery procedure for SC285 and no replacement preparation of laser optics housing unit If SC285 occurs or you did not do the procedure in ‘Before removing the old laser optics housing’ before removing the old laser optics housing unit, you must do the following. 1. Turn off the main power switch and disconnect the power cord of the copier. 2. Remove the left cover and...
Page 160
B230/B237 3-32 SM 2. Harness cover bracket [B] ( x 4). 3. Rear fan bracket [C] for the laser housing optics unit ( x 3, x 7) 4. Front fan bracket [D] for the laser housing optics unit ( x 2) 5. Remove the old laser optics housing unit [E] ( x 2, x 2)