Page 14
- 14 - RCI-6900F HP RCI-6900F TB CHAPTER 4 ALIGNMENT 4.0 REQUIRED TEST EQUIPMENT ! DC Power Supply (13.8VDC, 20A) RF Wattmeter (25~60 MHz, 100W) # Multimeter (Digital) $ Automatic Modulation Meter % Audio Signal Generator & Frequency Counter (100 MHz) RF Signal Generator (100 MHz) ( Automatic Distortion Meter ) Oscilloscope (50 MHz) * Sinad Meter 4.1 ALIGNMENT PROCEDURES This transceiver has been aligned at the factory and does not require any adjustments at...
Page 15
- 15 - ITEM U.U.T. SETTING ADJUST POINT MEASUREMENT TX Power Set radio to Fr. Pool 2, CH 19 AM TX mode. Modulation Off. Set radio to Fr. Pool 2, CH 19 USB TX mode. AF signal 30mV, 1 KHz to microphone. Connect Oscilloscope to TP12. Set RF PWR Fully Clockwise. Set FINE/COARSE Control to 12 o’clock. L18,L37,L35, L34 L35,L34 Maximum Output. Maximum Output and Balance. AM APC Set radio to Fr. Pool 2, CH 19 AM TX mode. Connect Multimeter to TP8. VR15 6VDC SSB APC Set...
Page 16
- 16 - ITEM U.U.T. SETTING ADJUST POINT MEASUREMENT AM Sensitivity Set radio to Fr. Pool 2, CH 19 AM RX mode. Set RF Gain Fully Clockwise. Set SQ Fully Counter Clockwise. Set VOL Control at 2 o’clock. Set NB/ANL/OFF switch to OFF position. Connect RF SG to antenna jack Frequency 28.915 MHz, 1uV. Mod 30%. Set radio to Fr. Pool 6, CH 40 AM RX mode. RF SG setting 29.655 MHz. Set radio to Fr. Pool 1, CH 1 AM RX mode. RF SG setting 28.245 MHz. L2,3,5,6,7,8, 9,10 L5,L6 L5,L6...
Page 18
- 18 - Figure 4-3 Main PCB Adjustment Location RCI-6900F HP RCI-6900F TB CHAPTER 5 MAINTENANCE
Page 19
- 19 - 5.0 PRECAUTIONS The inherent quality of the solid-state components used in this transceiver will provide many years of continuous use. Taking the following precautions will prevent damage to the transceiver. (i) Never key the transmitter unless an antenna or suitable dummy load is connected to the antenna receptacle. (ii) Ensure that the input voltage does not exceed 16 VDC or fall below 11 VDC. (iii) During alignment, do not transmit for more than 10 seconds at a time....
Page 20
- 20 - 6.0 GENERAL Information on most electrical and mechanical parts is included in the parts list. The reference designators are in alphanumeric order. 6.1 ORDERING REPLACEMENT PARTS Parts orders should be referred to the parts department at: • Ranger Communications, Inc. 3377 Carmel Mountain Road San Diego, CA 92121 Tel: 858-259-0287 Fax: 858-259-0437