    Set the VMD areas [VMD area]
    Click the [VMD area] tab on the Alarm setup page. (page 28)
    The video motion detection areas can be set on this page. 
    When a motion is detected in the set area, the alarm action will be perf\
    ormed. 
    Note:
    It will take around 5 minutes to start detection after the power is turn\
    ed on.
    Set the VMD areas
    Step 1
    Set the video motion detection area by dragging the
    mouse on the screen. When the [All areas] button is
    clicked, the whole area will become the VMD area, and
    1 (White) will be automatically applied to Area. → The designated area will become the VMD area and
    the outline will be displayed. When 2 - 4 VMD areas
    are set, each area will be numbered in order. The
    areas will be identified by the respective outline col-
    ours.
    Step 2
    Select ON or OFF for Status of each VMD area.
    When the [SET] button is clicked after selecting OFF,
    the outline will become the broken line and no alarm
    action will be performed even when a motion is detected
    in the area.
    Step 3
    Select Detect or Mask for Type of each VMD area. 
    When Mask is selected, the respective VMD area will
    be shaded. Any motion will not be detected in the VMD
    area for which Mask is selected. Select Mask for the
    area where any motion is not to be detected.
    Step 4
    Select the detection sensitivity from the following. 
    When Mask is selected for Type, this setting will be
    invalid for the respective VMD area.
    High/Middle/Low
    Default: Middle
    Step 5
    Select the direction from the following. Only a motion
    that moves to the selected direction will be detected.
    When Mask is selected for Type, this setting will be
    invalid for the respective VMD area.
    None/Up/Down/Left/Right
    Default: None 
    						
    							32
    Step 6
    Select ON or OFF for Light detection control. 
    When ON is selected, detection errors caused by turn-
    ing lighting on/off can be diminished.
    Notes:
    •Complete prevention of detection error is not guar-
    anteed even if using this function. 
    •When ON is selected, performance of the motion
    detection may be lower. 
    Step 7
    Click the [SET] button after completing the settings.
    Important:
    The setting will not be applied unless the [SET] but-
    ton is clicked.
    Delete the set VMD area
    Step 1
    Click the [DEL] button respective to the area to be delet-
    ed. 
    →The outline of the area will disappear and the select-
    ed area will be deleted. 
    Step 2
    Click the [SET] button after completing settings. 
    						
    							33
    Configure the settings relating to the mail notification [Notification]
    Click the [Notification] tab on the Alarm setup page. (page 28)
    The settings relating to the alarm mail can be configured on this page. To notify of an alarm occurrence by e-mail, it
    is necessary to configure the settings of the mail server. (page 37)
    [E-mail notification]
    Select ON or OFF to determine whether or not to
    notify of an alarm occurrence by e-mail at an alarm
    occurrence. 
    Default:OFF
    [Address]
    Enter the destination mail address. Up to 4 destination
    addresses can be registered.
    To notify by e-mail, check the Notification setup check-
    box respective to the desired address. To delete the
    registered address, click the [DEL] button respective to
    the desired address. 
    Number of characters for the destination mail
    address:3 - 128 characters
    [Mail subject]
    Enter the mail subject. 
    Number of characters for the mail subject:0 - 50
    characters
    [Mail body]
    Enter the mail body. 
    Number of characters for the mail body:0 - 200 char-
    acters 
    						
    							34
    Configure the settings relating to Panasonic alarm protocol
    [Panasonic alarm protocol setup]
    Click the [Notification] tab on the Alarm setup page. (page 28)
    The settings relating to Panasonic alarm protocol can be configured on this page. 
    [Panasonic alarm protocol]
    Select ON or OFF to determine whether or not to
    notify of an alarm occurrence by Panasonic alarm proto-
    col when an alarm is detected. 
    Default:OFF
    [Destination port]
    Select a destination port of the Panasonic alarm proto-
    col from the following.
    Available port number:1 - 65535
    Default:1818
    [Retry times]
    Select a retry time of Panasonic alarm protocol.  
    Available retry times:1 - 30
    Default:2
    [IP address]
    Enter the destination IP address of the Panasonic alarm
    protocol from the following. Up to 8 destination address-
    es can be registered.
    To notify by Panasonic alarm protocol, check the
    Notification setup checkbox respective to the desired
    IP address. To delete the registered IP address, click
    the [DEL] button respective to the desired IP address.  
    						
    							35
    Configure the settings relating to the authentication
    [Authentication setup]
    The settings relating to the authentication such as users and PCs (IP addresses) restrictions for accessing the cam-
    era can be configured on the Authentication setup page. 
    The Authentication setup page has 2 tabs of the [User] tab and the [Host] tab.
    Configure the settings relating to the user authentication [User]
    Click the [User] tab on the Authentication setup page.
    The settings relating to the user authentication can be configured on this page. Up to 16 users can be registered. 
    [User authentication]
    Select ON or OFF to determine whether or not to
    authenticate the user.
    Default:OFF
    [User name]
    Enter a user name.
    Number of characters for the user name:1 - 32 char-
    acters
    Default:(blank)
    [Password] [Retype password]
    Enter the password.
    Number of characters for the password:4 - 32 char-
    acters
    Default:(blank)
    Note:
    When the user name already in use is entered and
    the [REG] button is clicked, the respective user infor-
    mation will be overwritten. 
    [Access level]
    Select the access level of the host from the following. 
    1. Administrator:Allowed all available operations of
    the camera. 
    2. Camera control:Allowed to display images from the
    camera and to control the camera. The camera set-
    ting configuration is unavailable. 
    3. Live only:Only displaying live images is available.
    The camera setting configuration and camera con-
    trol are unavailable. 
    Default:3. Live only
    Note:
    By clicking [i] of User name check, the registered
    user can be selected and the selected user’s infor-
    mation can be checked. 
    The registered user will be displayed with the access
    level. (Example: admin [1])
    To delete the registered user, click the [DEL] button
    after selecting the user to be deleted. 
    						
    							36
    Configure the settings relating to the host authentication [Host]
    Click the [Host] tab on the Authentication setup page. (page 35)
    The settings to restrict PCs (IP address) to access the camera can be configured on this page.
    [Host authentication]
    Select ON or OFF to determine whether or not to
    authenticate the host.
    Default:OFF
    Important:
    Before configuring the host authentication, it is nec-
    essary to register IP addresses of the PCs to be
    allowed to access the camera and determine their
    access levels. If ON is selected for Host authenti-
    cation before registering the hosts (IP addresses), it
    will be impossible to access the camera. 
    [IP Address]
    Enter the IP address of the PC to be allowed to access
    the camera.
    Notes:
    •When IP address/subnet mask is entered, it is pos-
    sible to restrict PCs in each subnet. 
    •When the IP address already in use is entered and
    the [REG] button is clicked, the respective host infor-
    mation will be overwritten. 
    [Access level]
    Select the access level of the host from the following. 
    1. Administrator/2. Camera control/3. Live only
    Refer to page 35 for further information about the
    access level.
    Default:3. Live only
    Note:
    By clicking [i] of Host check, the registered host
    can be selected and the selected host’s IP address
    can be checked. 
    The registered IP address will be displayed with the
    access level. (Example: 192.168.0.21 [1])
    To delete the registered host, click the [DEL] button
    after selecting the IP address to be deleted. 
    						
    							37
    Configure the settings of the servers [Server setup]
    The settings relating to the mail server and the FTP server can be configured on this page. 
    The Server setup page has 2 tabs of the [Mail] tab and the [FTP] tab.
    Configure the settings relating to the mail server [Mail]
    Click the [Mail] tab on the Server setup page.
    The settings relating to the mail server used to send the alarm mail can be configured on this page. 
    [SMTP server address]*
    Enter the IP address or the host name of the SMTP
    server used to send e-mails.
    Number of characters for the SMTP server address:
    1 - 128 characters
    [POP server address]*
    When POP before SMTP is selected for
    Authentication, enter the IP address or the host name
    of the POP server.
    Number of characters for the POP server address:
    1 - 128 characters
    * Important:
    When entering the host name for POP server
    address, it is necessary to configure the DNS set-
    tings on the [Network] tab of the Network setup
    page. (page 39)
    [Authentication]
    Select the authentication method to send e-mails from
    the following. 
    None:It is unnecessary to clear any authentication to
    send e-mails.
    POP before SMTP:It is necessary to clear the POP
    server authentication first to use the SMTP server to
    send e-mails. 
    SMTP:It is necessary to clear the SMTP server authen-
    tication to send e-mails.
    Default:None
    [User name]
    Enter the user name to access the server. 
    Number of characters for the user name:1 - 32 char-
    acters
    [Password]
    Enter the password to access the server. 
    Number of characters for the password:0 - 32 char-
    acters
    [Sender mail address]
    Enter the mail address of a sender.
    Entered mail address will be displayed in the From
    (sender) line of the sent mails.
    Number of characters for the sender address:
    3 - 128 characters 
    						
    							38
    Configure the settings relating to the FTP server [FTP]
    Click the [FTP] tab on the Server setup page. (page 37)
    The settings relating to the FTP server used to transmit the alarm images can be configured on this page. 
    [FTP server address]
    Enter the IP address or the host name of the FTP serv-
    er. 
    Number of characters for the FTP server address:
    1 - 128 characters
    Important:
    When entering the host name for FTP server
    address, it is necessary to configure the DNS set-
    tings on the [Network] tab of the Network setup
    page. (page 39)
    [User name]
    Enter the user name (login name) to access the FTP
    server. 
    Number of characters for the user name:1 - 32 char-
    acters
    [Password]
    Enter the password to access the FTP server. 
    Number of characters for the password:0 - 32 char-
    acters
    [Control port]
    Enter a control port number to be used for the FTP serv-
    er.
    Available port number:1 - 65535
    Default:21[FTP mode]
    Select Passive or Active for the FTP mode.
    Normally, select Passive. When failed to establish the
    connection, select Active.
    Default:Passive 
    						
    							39
    Configuring the network settings [Network setup]
    The network settings and the settings relating to DDNS (Dynamic DNS) and SNMP (Simple Network management
    Protocol) can be configured on this page. 
    The Network setup page has 3 tabs of the [Network] tab, the [DDNS] tab, the [SNMP] tab and the [FTP] tab. 
    Configure the network settings [Network]
    Click the [Network] tab on the Network setup page.
    The following information is required to configure the network settings. 
    Contact the network administrator or your Internet service provider.
    •IP address
    •Net mask
    •Default gateway (when using the gateway server/router)
    •HTTP port
    •Primary DNS, Secondary DNS (when using DNS)
    [DHCP]
    Select ON or OFF to determine whether or not to use
    the DHCP function.
    Default:OFF
    [IP address]
    When not using the DHCP function, enter the IP
    address of the camera. Do not enter the IP address
    already in use (for the PCs and the other network cam-
    eras). 
    Default:192.168.0.10
    
    0.*.*.*
    *.*.*.0
    255.*.*.*
    *.*.*.255
    127.0.0.1
    Class D address (224.0.0.0 - 239.255.255.255)
    Class E address (240.0.0.0 - 255.255.255.255)
    [Net mask]
    When not using the DHCP function, enter the net mask
    of the camera. 
    Default:255.255.255.0
    [Default gateway]
    When not using the DHCP function, enter the default
    gateway of the camera. 
    Default:192.168.0.1
    
    0.*.*.*
    *.*.*.0
    255.*.*.*
    *.*.*.255
    127.0.0.1
    Class D address (224.0.0.0 - 239.255.255.255)
    Class E address (240.0.0.0 - 255.255.255.255) 
    						
    							40
    [HTTP port]
    Assign the port numbers independently. 
    The following port numbers are unavailable since they
    are already in use.
    Available port number:1 - 65535
    Default:80
    
    20, 21, 23, 25, 42, 53, 67, 68, 69, 110, 123, 161,
    162, 995, 10669, 10670
    [DNS]
    Select AUTO or MANUAL to determine whether or
    not to use the DNS. When MANUAL is selected, it is
    necessary to configure the settings for the DNS.
    When using the DHCP function, it is possible to obtain
    the DNS address automatically by selecting AUTO.
    Refer to the network administrator for further information
    about the settings. 
    Default:MANUAL
    [Primary DNS], [Secondary DNS]
    When MANUAL is selected for DNS, enter the IP
    address of the DNS. Refer to the network administrator
    about the IP address of the DNS.
    [Line speed]
    Select the line speed for data transmission from the fol-
    lowings. It is recommended to use with the default set-
    ting AUTO. 
    AUTO/100MF (Mbps full-duplex)/100MH (Mbps half-
    duplex)/10MF (Mbps full-duplex)/10MH (Mbps half-
    duplex)
    Default:AUTO
    [FTP access]
    Select Allow or Forbid to determine whether to allow
    or forbid the FTP access.
    Default:Allow
    [Total bit rate]
    Select the total bit rate for data transmission from the
    followings.
    64 kbps/128 kbps/256 kbps/512 kbps/1024 kbps/
    2048 kbps/4096 kbps/10 Mbps/Unlimited
    Default:Unlimited
    Notes:
    •When selecting 64 kbps, select OFF for Mic
    mode on the Audio tab. (page 26)
    •When 64 kbps is selected, it is impossible to carry
    out the live-transmission of JPEG images and the
    FTP periodic transmission simultaneously. 
    						