Page 21
-18- Playback Picture of CH 1Playback Picture of CH 2 Playback Picture of CH 3Playback Picture of CH 4 Playback Picture of CH 5Playback Picture of CH 6 Playback Picture of CH 7Playback Picture of CH 8 Example of quad playback picture sequence C. Single Spot or Quad Playback Picture Sequences 1. Repeat procedures A (Single Spot Picture) to moni- tor a single spot playback picture or procedures B (Multi Spot Picture) to monitor quad playback pic- tures. Note:To monitor quad multi spot pictures, press...
Page 22
-19- Note:Two or more pictures on the monitor can be selected in multi picture mode. 6. Press the camera selection button whose indicator is blinking. The selected picture is displayed again for normal monitoring. 7. To release STILL ON mode, set the MODE SELECT/ CAMERA SELECT switch to MODE SELECT, then press button 16 (STILL ON). The STILL ON indicator goes out. Notes: • If you press the camera selection button for a cam- era whose picture is not displayed on the monitor screen, the operation is...
Page 23
-20- MULTISCR Mode Select this mode to monitor the camera pictures. Selection of MULTISCR mode permits the following operations. Monitoring the camera picture A. Single Spot Picture Proceed as described in “Monitoring the Camera Picture, A. Single Spot Picture” on page 15. B. Multi Spot Picture 1. Set the MODE SELECT/CAMERA SELECT switch to CAMERA SELECT. 2. Press the ZOOM/MULTISCREEN/QUAD SHIFT but- ton. The multiscreen appears on the monitor. 3. Set the MODE SELECT/CAMERA SELECT switch to MODE SELECT....
Page 24
-21- Notes: • If you press the camera selection button for a camera whose picture is not displayed on the monitor screen, the operation is ignored. • The word “STILL” is not displayed if STILL/ ALARM DISP in MENU 2 OF 3 is set to OFF. D. Still Multi Spot Picture The following function is available in multi spot picture mode only. 1. Set the MODE SELECT/CAMERA SELECT switch to MODE SELECT. 2. Press the (STILL ON) button 16. The STILL ON indi- cator lights. 3. Set the MODE SELECT/CAMERA SELECT to CAM- ERA...
Page 25
-22- nRefer to the operating instructions of each system component for connection and operation. CAMERA IN CAMERA OUTPLAY IN MONITOR OUT ALARM/REMOTE CAMERA SW IN SIGNAL GND 16 15 14 1312 11 10 98 654 3 21 7 16 15 1413 12 11 10 9 86 5432 1 7 REC OUT Cameras Cameras Camera Drive Unit VIDEO OUTPUT VIDEO OUTPUTVideo Monitor VIDEO INPUT VIDEO INPUT VIDEO OUTPUT CAMERA SWITCH Time Lapse VTRCameras Note:The WV-80 cannot be used in this system. CONNECTION
Page 26
-23- Sensor 16 Sensor 1 Buzzer NO C NC To Buzzer Relay +24V NC: Normally Closed Contact NO: Normally Open Contact C: Common • Connection with the Alarm Sensor You can connect an alarm sensor to record the pic- tures of channels that receive alarm input signal. Use an alarm sensor that meets the following con- ditions: 1. The power capacity must be less than 5 V DC (open collector output or normally open con- tact). 2. The voltage between the alarm connector and the ground terminal...
Page 27
-24- nConnection with the Time Lapse VTR Connect the time lapse VTR as shown in the example below. 246810121416 ALARM IN 1 COM2ALARM RESET IN 3 ALARMRECOVER OUT4 ALARM OUT 5 1 SHOT IN6 7TAPE END OUT8 WARNING OUT 9 HUMID OUT10 REC OUT 11REC REVIEW OUT12 SERIES REC IN 13 14TIME ADJUST IN 15 TIME ADJUST OUT16 COMSERIES REC OUT 13579111315 PLAY IN ALARM/REMOTECAMERA SW INREC OUT131 14 25 Video Multiplexer WJ-FS216 VIDEO INVIDEO OUTS-VIDEO AUDIOCAMERA SW OUTGND 24 22 147 Time Lapse VTR
Page 28
-25- • Remote Control You can control the SEQUENCE, MULTISCREEN/QUAD SHIFT, and the camera selection buttons from a remote con- troller. These functions are activated by contact with the ground terminal (open collector output or normally open con- tact). • Connect the ALARM/REMOTE connector (pin 23) to the ground terminal as shown below. Switches 1 - 16 select the cameras (they do not control the alarm input). Notes: • Any two or more switches closed at the same time will cause this unit to...
Page 29
-26- Power Source: 220 - 240 V AC 50 Hz Power Consumption: 12 W Camera Input: 16 (BNC) 2:1 interlaced VBS 1.0V[p-p]/75 W automatic termination/looping through Playback Input: 1 (BNC) VBS 1.0V[p-p]/75 W Monitor Output: 1 (BNC) VBS 1.0V[p-p]/75 W Recording Output: 1 (BNC) VBS 1.0V[p-p]/75 W Camera Switching Input: 1 RCA pin jack Alarm Input: 16 Alarm Output: 1 Open-collector 24V DC 100 mA max. Alarm Recover Input: 1 Operating Temperature:-10°C - +50°C (14°F - 122°F) Operating Humidity: Less than 90%...
Page 30
Matsushita Electric Industrial Co., Ltd. Central P.O. Box 288, Osaka 530-91, Japan N0896-1117 YWV8QA4469BN Printed in JapanN30 Gedruckt in Japan Imprimé au Japon Impreso en Japón