-18- Playback Picture of CH 1Playback Picture of CH 2 Playback Picture of CH 3Playback Picture of CH 4 Playback Picture of CH 5Playback Picture of CH 6 Playback Picture of CH 7Playback Picture of CH 8 Example of quad playback picture sequence C. Single Spot or Quad Playback Picture Sequences 1. Repeat procedures A (Single Spot Picture) to moni- tor a single spot playback picture or procedures B (Multi Spot Picture) to monitor quad playback pic- tures. Note:To monitor quad multi spot pictures, press button 1 ( ). Sequential 3x3 and 4x4 play- back pictures are not available. 2. Press the SEQUENCE/ALARM RESET button for sequential display of playback pictures. Note:Sequential pictures appear in the last select- ed mode. Sequential single spot pictures are displayed on a single picture screen, and sequential quad pictures on a quad screen. Playback Picture of CH 3 Playback Picture of CH 6Example of single spot playback picture sequence 3. To cancel sequential picture display, press the desired camera selection button. The selected playback picture appears on the sin- gle picture screen of the monitor. SEQENCE ALARM RESET D. Still Playback Picture 1. Repeat procedures A (Single Spot Picture) or pro- cedures B (Multi Spot Picture) to monitor playback pictures. 2. Set the MODE SELECT/CAMERA SELECT switch to MODE SELECT. 3. Press button 16 (STILL ON). The STILL ON indicator lights. 4. Set the MODE SELECT/CAMERA SELECT switch to CAMERA SELECT. 5. Press one of the camera selection buttons whose indicator is lit. The LED on the pressed button starts blinking, and the picture corresponding to that button appears still on the monitor. The word STILL appears blinking on the monitor screen. STILL ON 16 ENTRANCE Normal Playback Picture STILL Still Picture (The word STILL blinks) Normal Playback Picture ENTRANCE Still Picture (The word STILL blinks) STILL
-19- Note:Two or more pictures on the monitor can be selected in multi picture mode. 6. Press the camera selection button whose indicator is blinking. The selected picture is displayed again for normal monitoring. 7. To release STILL ON mode, set the MODE SELECT/ CAMERA SELECT switch to MODE SELECT, then press button 16 (STILL ON). The STILL ON indicator goes out. Notes: • If you press the camera selection button for a cam- era whose picture is not displayed on the monitor screen, the operation is ignored. • The word “STILL” is not displayed if STILL/ALARM DISP in MENU 2 OF 3 is set to OFF. • While the still picture is displayed, the VTR keeps playing the playback picture. E. Single Spot Picture Zoom The following function is available in single spot pic- ture mode only. 1. Repeat procedures A (Single Spot Picture) to moni- tor the playback picture. 2. Set the MODE SELECT/CAMERA SELECT switch to CAMERA SELECT. 3. Press the ZOOM/MULTISCREEN/QUAD SHIFT button. The “+” sign appears in the picture. Note:The “+” sign disappears if no operation is performed within approx. 5 seconds. 4. Press button 14 (+) to zoom in, or button 13 (–) to zoom out. Notes: • Each time button 14 (+) is pressed, the picture is zoomed in. Zooming stops when it reaches the maximum level. • The picture cannot be zoomed out to be small- er than the original size by pressing button 13 (–). 5. To move the picture, press buttons 9 - 12 (D D, C C, A A, B B). The zoomed picture will move up, down, left, or right depending on the button pressed. The picture will stop at the edge of the monitor screen. Normal Playback Picture Playback Picture with the + sign Zoomed Playback Picture ENTRANCE Notes: • In monitoring single spot playback pictures, only one zoom level is available. • The title in the picture disappears when the ZOOM/MULTISCREEN/QUAD SHIFT button is pressed. The title remains off the screen even after the “+” • sign disappears. To call the title back on the screen, quit the zoom function and operate another function.
-20- MULTISCR Mode Select this mode to monitor the camera pictures. Selection of MULTISCR mode permits the following operations. Monitoring the camera picture A. Single Spot Picture Proceed as described in “Monitoring the Camera Picture, A. Single Spot Picture” on page 15. B. Multi Spot Picture 1. Set the MODE SELECT/CAMERA SELECT switch to CAMERA SELECT. 2. Press the ZOOM/MULTISCREEN/QUAD SHIFT but- ton. The multiscreen appears on the monitor. 3. Set the MODE SELECT/CAMERA SELECT switch to MODE SELECT. 4. Press button 1 ( ), 2 ( ), or 3 ( ) to select multiscreen pattern (quad, 3x3, or 4x4). Notes: • Some frames are skipped as the picture seg- ments are displayed. • Multi spot pictures being monitored may some- times vibrate vertically, but this does not indi- cate a malfunction. • Quad shift is available by pressing the ZOOM/ MULTISCREEN/QUAD SHIFT button. Refer to page 17 for more details. Quad 3 x 3 4 x 4 12 34 123 456 789 1256 3478 9 101314 11 12 15 16 C. Single Spot or Quad Picture Sequences You can monitor sequential spot pictures or quad pictures. First select a display pattern. To monitor sequential single spot pictures, take the same steps as described in procedures B for “Single Spot Picture Sequences of Monitoring Camera Pictures“ on page 15. To monitor sequential quad pictures, proceed as described in the following procedures. 1. Take steps 1 to 3 of Procedures B for Multi Spot Pictures. 2. Press button 1 ( ) to select quad pictures. 3. Press the SEQUENCE/ALARM RESET button. The quad pictures appear sequentially in the order of dwell times set in the SEQUENCE SETUP in MENU 3 OF 3. Camera 1 PictureCamera 2 Picture Camera 5 PictureCamera 6 Picture Example of quad picture sequence Camera 8 PictureCamera 10 Picture Camera 12 PictureCamera 16 Picture 4. To cancel sequential picture display, press the desired camera selection button. The selected camera picture appears on the single picture screen of the monitor.
-21- Notes: • If you press the camera selection button for a camera whose picture is not displayed on the monitor screen, the operation is ignored. • The word “STILL” is not displayed if STILL/ ALARM DISP in MENU 2 OF 3 is set to OFF. D. Still Multi Spot Picture The following function is available in multi spot picture mode only. 1. Set the MODE SELECT/CAMERA SELECT switch to MODE SELECT. 2. Press the (STILL ON) button 16. The STILL ON indi- cator lights. 3. Set the MODE SELECT/CAMERA SELECT to CAM- ERA SELECT. 4. Press one of the camera selection buttons whose indicator is lit. The LED on the pressed button starts blinking and the picture corresponding to that button appears still on the monitor. The word STILL appears blinking on the monitor screen. 5. Press the camera selection button whose indicator is blinking. The selected picture is displayed again for normal monitoring. 6. To release STILL ON mode, set the MODE SELECT/ CAMERA SELECT switch to MODE SELECT, then press button 16 (STILL ON). The STILL ON indicator goes out. Normal Camera Picture ENTRANCE Still Picture (The word STILL blinks) STILL Normal Camera Picture Picture with the + sign Zoomed Picture ENTRANCE E. Zoomed Multi Spot Picture The following function is available in multi spot picture mode only. 1. Set the MODE SELECT/CAMERA SELECT switch to MODE SELECT. 2. Press the ZOOM/MULTISCREEN/QUAD SHIFT button. The “+” sign appears in the picture. Note:The “+” sign disappears if no operation takes place within approx. 5 seconds. 3. Move the “+” sign to the picture you want to zoom by pressing buttons 9-12 (D D, C C, A A, B B). 4. Press button 14 (+) to zoom in. To zoom out, press button 13 (-). Notes: • Each time button 14 (+) is pressed, the picture is zoomed in. Zooming stops when it reaches the maximum level. • The picture cannot be zoomed out to be smaller than the original size by pressing button 13 (–). 5. To move the picture, press buttons 9 - 12 (D D, C C, A A, B B). The zoomed picture will move up, down, left, or right depending on the button pressed. The picture will stop at the edge of the monitor screen. Notes: • When you change the multiscreen pattern (for example, quad to 3x3), the size of the zoomed pic- ture is not the same even if the picture is from the same channel. • The title in the picture disappears when the ZOOM/MULTISCREEN/QUAD SHIFT button is pressed. The title remains off the screen even after the “+”• sign disappears. To call the title back on the screen, quit the zoom function and operate another function.
-22- nRefer to the operating instructions of each system component for connection and operation. CAMERA IN CAMERA OUTPLAY IN MONITOR OUT ALARM/REMOTE CAMERA SW IN SIGNAL GND 16 15 14 1312 11 10 98 654 3 21 7 16 15 1413 12 11 10 9 86 5432 1 7 REC OUT Cameras Cameras Camera Drive Unit VIDEO OUTPUT VIDEO OUTPUTVideo Monitor VIDEO INPUT VIDEO INPUT VIDEO OUTPUT CAMERA SWITCH Time Lapse VTRCameras Note:The WV-80 cannot be used in this system. CONNECTION
-23- Sensor 16 Sensor 1 Buzzer NO C NC To Buzzer Relay +24V NC: Normally Closed Contact NO: Normally Open Contact C: Common • Connection with the Alarm Sensor You can connect an alarm sensor to record the pic- tures of channels that receive alarm input signal. Use an alarm sensor that meets the following con- ditions: 1. The power capacity must be less than 5 V DC (open collector output or normally open con- tact). 2. The voltage between the alarm connector and the ground terminal must be 0-0.8 V when con- tact is made. Connect the sensor switch and the alarm input con- nector. Note: Leave connector pin 23 blank. • Connection with the Alarm Output Connector Power capacity of alarm output connector less than 100 mA: • Make sure to match the polarity when connect- ing the buzzer to the alarm output connector. • Connect the positive pole (+) of the buzzer to pin 24 of the alarm output connector.Power capacity of alarm output connector more than 100 mA: • Connect the buzzer through a relay circuit to pin 24 of the alarm output connector. Do not connect it directly.
-24- nConnection with the Time Lapse VTR Connect the time lapse VTR as shown in the example below. 246810121416 ALARM IN 1 COM2ALARM RESET IN 3 ALARMRECOVER OUT4 ALARM OUT 5 1 SHOT IN6 7TAPE END OUT8 WARNING OUT 9 HUMID OUT10 REC OUT 11REC REVIEW OUT12 SERIES REC IN 13 14TIME ADJUST IN 15 TIME ADJUST OUT16 COMSERIES REC OUT 13579111315 PLAY IN ALARM/REMOTECAMERA SW INREC OUT131 14 25 Video Multiplexer WJ-FS216 VIDEO INVIDEO OUTS-VIDEO AUDIOCAMERA SW OUTGND 24 22 147 Time Lapse VTR
-25- • Remote Control You can control the SEQUENCE, MULTISCREEN/QUAD SHIFT, and the camera selection buttons from a remote con- troller. These functions are activated by contact with the ground terminal (open collector output or normally open con- tact). • Connect the ALARM/REMOTE connector (pin 23) to the ground terminal as shown below. Switches 1 - 16 select the cameras (they do not control the alarm input). Notes: • Any two or more switches closed at the same time will cause this unit to malfunction. • SEQUENCE is assigned to switch 17 and MULTISCREEN/QUAD SHIFT to switch 18. • When no operation is taking place, all switches except switch 19 must be open as shown below. 15161413121110987654321171819SwitchSwitch GROUNDSEQUENCE MULTISCREEN /QUAD SHIFTSwitch Camera Selection D-SUB CONNECTOR (MALE)
-26- Power Source: 220 - 240 V AC 50 Hz Power Consumption: 12 W Camera Input: 16 (BNC) 2:1 interlaced VBS 1.0V[p-p]/75 W automatic termination/looping through Playback Input: 1 (BNC) VBS 1.0V[p-p]/75 W Monitor Output: 1 (BNC) VBS 1.0V[p-p]/75 W Recording Output: 1 (BNC) VBS 1.0V[p-p]/75 W Camera Switching Input: 1 RCA pin jack Alarm Input: 16 Alarm Output: 1 Open-collector 24V DC 100 mA max. Alarm Recover Input: 1 Operating Temperature:-10°C - +50°C (14°F - 122°F) Operating Humidity: Less than 90% Dimensions: 420 (W) x 44 (H) x 350 (D) [16-9”(W) x 3-7/16(H) x 13-3/4”(D)] Weight: 4 kg(8.8 lbs) Dimensions and weight are approximate. Specifications are subject to change without notice. STANDARD ACCESSORIES Rack Mounting Angle ...................................... 2 pcs. Screws (M3 x 10) ............................................. 8 pcs. Switch Protector ................................................ 1 pc. SPECIFICATIONS
Matsushita Electric Industrial Co., Ltd. Central P.O. Box 288, Osaka 530-91, Japan N0896-1117 YWV8QA4469BN Printed in JapanN30 Gedruckt in Japan Imprimé au Japon Impreso en Japón