3. Insert the fan body between joists. Make sure the fan body is level and square (perpendicular)with the joists.(Fig. 16) Keep the distance B (7/8 inch, 21.6mm) for the thickness of ceiling board. 4. Secure the suspension bracket to joists by using long screws(M4X30) (Fig. 17, Fig. 18) inches mm() 11 5. Secure the suspension bracket to fan body by using screw (M4x10) (Fig. 18)II 6. Follow steps 5 to 9 of installation (page 7, page 8) to complete the installation work.I Adaptor Ventilating fanCeiling joist Junction box 2-Long screws(M4X30) Joist 4-Long screws(M4X30) 2-Screw (M4X10)II Fig. 17 Fig. 16 Fig. 18 A13 1/4~15 3/4 ( 336~400 ) 16 1/2~18 3/4 ( 419~480 ) B7/8 (21.6) 3~5 ( 76~126 ) 5 4/5~7 4/5 ( 148~198 )
Fig. 20 Fig. 19 (275)(375)10 7/814 3/42. Install header between joists by using nails or screws. 3. Install the ventilating fan and secure it by using long screws (M4X30) (Fig. 19, Fig. 20) 12 1. Before installation, open the orifice cover. Secure the fan body to adaptor by using thumb screw. (Fig. 1 of page 6) 4. Follow steps 5 to 9 of installation (page 7, page 8) to complete the installation work.I (2) Inspect duct work and wiring before proceeding with installation. (3) Plan suitable location for ventilating fan. (next to ceiling joist) (5) First, remove ceiling section according to Fig. 6 of page 8. (6) Install ventilating fan. (1) To install the ventilating fan, follow the procedures described in lnstallation . Take the following precautions before installation.II 1. Installation in existing construction. Installing the ventilating fan in an existing building requires an accessible area (attic or crawl space) above the planned installation location or existing ducting and wiring. CAUTION: Check area above planned installation location to be sure that: 1. Duct work can be installed and that area is sufficient for proper ventilation. 2. Wiring can be run to planned location. 3. No wiring or other obstructions will interfere with installation. (4) Before installation, provide inspection and maintenance access at a location that will not interfere with installation work shown in installation .II Adaptor inches (mm)Ventilating fanJoist Header Joist Wire nut Conduit Junction box Green wires Lead wires 6-Long screws (M4X30) Adaptor Circular duct (1) Inspect duct work and wiring before proceeding with installation. (2) Remove ceiling section according to Fig. 6 of page 8. (3) Install ventilating fan. 2. Installation from accessible area above fan location.
3. Remove dust and dirt from fan body using a vacuum cleaner. (Fig. 23) 4. Using a cloth dampened with kitchen detergent, remove any dirt from fan body. Wipe dry with new cloth. (Fig. 24) 5. Replace grille. Disconnect power source before working on unit. Routine maintenance must be done every year. WARNING: CAUTION: 1. Never use petrol, benzene, thinner or any other such chemicals for cleaning the ventilating fan. 2. Do not allow water to enter motor. 3. Do not immerse resin parts in water over 60 C. o 1. Remove grille. (Squeeze mounting spring and pull down carefully.) (Fig. 21) 2. Wash and clean grille. (Use non-abrasive kitchen detergent, wipe dry with new cloth.) (Fig. 22) Glove GrilleSlot Mounting spring Grille 13 Vacuum cleaner Fig. 21 Fig. 22 Fig. 24 Fig. 23
PANASONIC CONSUMER ELECTRONICS COMPANY One Panasonic Way, 1H-3 Secaucus, NJ 07094 PANASONIC CANADA INC. 5770 Ambler Drive, Mississauga, ON L4W 2T3 Dryer-hood type vent with backdraft flap(s). Warning Concerning Removal of Covers. Fig. 25 Caulk termination to duct. 2-3 ft straight run before elbow. In attic installation, caulk box to drywall. Short piece of flexible duct helps alignment and absorbs sound. Clamps plus tape at all flex joints.Foil tape tightly covers all metal duct joints (glue PVC joints).Insulation.Loose fill or batt insulation can be placed directly over the fan housing in the attic. Panasonic fans and fan/light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitors fan/light combinations. Our efficient, cool-running motors and our fluorescent bulbs do not create enough ambient heat to be subjected to these limitations. Properly insulate the area around the fan to minimize building heat loss and gain. (Fig. 25) The unit should be serviced by qualified technicians only. No service information is provided for customers. Your product is designed and manufactured to ensure a minimum of maintenance. However, should your unit ever require service, a nationwide system of factory service centers and AUTHORIZED INDEPENDENT SERVICE CENTERS is maintained to support your products warranty. (In the U.S.A.,call 1-866-292-7292 to Customer call center.) 14