Home > Panasonic > Ventilation > Panasonic Ventilation Fan Fv 05vf2 Installation Instructions

Panasonic Ventilation Fan Fv 05vf2 Installation Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Ventilation Fan Fv 05vf2 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Ventilating FanFV-05VF2 FV-08VF2 FV-11VF2
    READ AND SAVE THESE INSTRUCTIONS.R
    Please
    readthese
    instructionscarefullybeforeattempting
    toinstall,
    operate or service the Panasonic Ventilating Fan. Failure to comply
    with instructions could result in personal injury and/or property
    damage. Please retain this booklet for future reference.
    SpecificationsDimensions
    Description
    Table of Contents
    Supplied Accessories
    Unpacking
    General Safety Information
    Wiring Diagram4
    4-54 32
    2
    5
    12 12
    13
    14 8-9
    Installation( Wooden Header )
    10( -Joist Mounting )I
    10-11Installation
    ( Between Joist Mounting )
    Installation( In Existing Construction )VIV
    Installation( Joist Mounting- )II
    Installation
    Maintenance
    Practical Guide to Installation
    14Product Service
    6-8IInstallation( Joist Mounting- )I
    II
    III
    IV 
    						
    							FV-05VF2
    FV-08VF2
    FV-11VF2
    These Panasonic ceiling mount ventilating fan models use a sirocco fan with dolphin-shaped blades driven by
    a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption.
    Double orifice technology is used to reduce noise. It also incorporates a thermal-cutoff for safety. The grille
    covering the main body is a spring-loaded, quickremove type. A damper for preventing counterflow is provided.
    1 81Thumb screwLong screw
    (M4X30)Quantity Appearance
    Part name
    Grille
    Suspension
    bracketI
    Suspension
    bracketII
    1
    1
    Screw
    (M4X8)I2
    1Suspension
    bracketIII
    Screw
    (M4X10)II2
    3 inches adaptor
    connector
    (optional part)
    1 
    						
    							Unit: ( )inches mm
    Damper
    Body Adaptor
    Grille
    Part name Part name
    No. No.
    1
    2
    3
    4
    67
    8
    Suspension bracket
    Orifice Orifice cover
    Bracket cover 59
    10 Junction box
    Adaptor connector
    11
    12
    Motor Blade
    (For 16 inches on center joists, only use suspension bracket , for 19.2 inches on center joists, only use
    suspension bracket , If more than 19.2 inches on center,use suspension bracket & .)I
    III II III
    FV-05VF2
    FV-08VF2 FV-11VF2
    6 1
    24
    37/8 98()
    3
    43/8 110()
    5 5/8 (141)
    9
    10
    3 1/4 (81)
    1 3/4 (43.5)
    2 15/16 (74)
    5
    11
    12
    13 330()
    10 1/4 261()
    16 1/8 (410)
    1 (25)
    78
    14
    37/8 98()
    33 5/8 (92)1(25)
    43/8 110()
    5 5/8 (141)
    9
    10
    3 1/4 (81)
    1 3/4 (43.5)
    10 1/4 259()
    11 7/8 (301)
    2 15/16 (74)
    5
    11
    12
    13 330()
    10 1/4 261()
    16 1/8 (410)
    1 (25)
    78
    13 1/4~15 1/2 ( 336~394 )
    16 1/2~18 3/4 ( 419~480 )
    21 1/4~23 1/2 ( 540~597 )
    1 (25)
    10 1/4 259()
    11 7/8 (301)13 1/4~15 1/2 ( 336~394 )
    16 1/2~18 3/4 ( 419~480 )
    21 1/4~23 1/2 ( 540~597 )
    3 5/8 (92) 
    						
    							Specifications are based on HVI standard.
    Unpack and carefully remove unit from carton.
    Refer to the Supplied Accessories list to verify that all parts are present.
    1. Do not install this ventilating fan where air temperature may exceed 40 C (104 F).oo
    2. Make certain that the electric service supply voltage is 120V, 60 Hz.
    3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and
    the Occupation Safety and Health Act (OSHA).
    4. Always disconnect the power source before working on or near the fan, motor or junction box.
    5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
    6. Do not kink the power cord.
    7. Do not install the unit where ducts are configured as shown in Fig. A.
    8. Provide suction parts with proper ventilation.
    9. This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected
    branch circuit.
    24
    Hz
    60
    V Air direction Model No.
    FV-05VF2
    FV-08VF2
    FV-11VF2
    Exhaust120
    (W)
    Power consumption
    15
    33
    Speed
    (rpm)Air deliver
    (cfm)
    3.5 (7.7)
    3.7 (8.2)
    3.8 (8.4)
    Weight
    kg(Ib.)
    Duct
    diameter
    (inches)
    4
    4
    4
    Noise
    (sone)
    Adaptor
    Fig. A
    50
    80
    11 0 635
    755
    830
    0.8
    1.50.4
    15 350 7400.5
    24 3
    70 8450.8
    33 3
    90 12301.5 
    						
    							Power Supply
    AC120V 60Hz
    Fan unit
    Red
    Capacitor
    White
    Black
    Green
    Earth groundJunction box
    GreenNeutral
    Live
    Earth
    CAUTION:
    1. For general ventilating use only. Do not use to exhaust
    hazardous or explosive materials and vapors.
    2. Not for use in cooking area. (Fig. B)
    3. This product must be properly grounded.Floor
    Do not install above or(Cooking area)
    inside this area
    45o45o
    equipmentCooking
    Fig. B
    WARNING:
    To reduce the risk of fire, electric shock or injury to persons, observe the following;
    A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact
    the manufacturer.
    B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all
    applicable codes and standards, including fire-rated construction.
    C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
    of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturers
    guideline and safety standards such as those published by the National Fire Protection Association
    (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers
    (ASHRAE) and the local code authorities.
    D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
    E. Ducted fans must always be vented to the outdoors.
    F. These models are UL listed for tub and shower enclosures.
    G. Solid state controls may cause harmonic distortion which can cause motor humming noise. Do not use
    this unit with any solid-state control device.
    H. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting
    means to prevent power from being switched on accidentally. When the service disconnecting means
    cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
    I. NEVER place a switch where it can be reached from a tub or shower.
    J. Not to be installed in a ceiling thermally insulated to a value greater than R40. 
    						
    							Press and hold the claw of orifice cover to open
    the orifice cover.
    1. Before installation, open the orifice cover. Secure the fan
    body to adaptor by using thumb screw. (Fig. 1)
    Fig. 1
    2. Insert the supension bracket into the fan body and
    adaptor. (select the suspension bracket acc rding
    to Fig. 2)o
    Remove the tape
    IMPORTANT:
    Adaptor
    Remove the tape from damper and adaptor
    before installation.As show below:
    Damper
    2-Screw (M4X8)I
    Suspension bracketIIISuspension bracketII
    If spacing A on center joists is 24 inches, connect
    suspension bracket and (C4 mark to C4 mark)
    as show below :II III
    Orifice cover
    Claw
    3 inches adaptor connector
    Connection method for 3 inches adaptor connector
    Duct tape
    Orifice cover
    Fan body
    Thumb screw
    Suspension
    bracketIII
    Suspension
    bracketI
    Fig. 2-3
    A = 19.2 inches vertical joists
    Fan body
    Suspension
    bracketI
    Fig. 2-1Fan body
    A = 12 inches
    Suspension
    bracketISuspension
    bracketIII
    Fig. 2-2
    A = 16 inches
    Fan body
    Fig. 2-4Fan body
    Suspension
    bracketI Suspension
    bracketIII
    Suspension
    bracketII
    A = 24 inches
    2
    1
    12
    3
    Joist
    A 
    						
    							5. Remove junction box cover and secure conduit or
    stress relief to junction box knock-out hole. (Fig. 5)
    6. Refer to wiring diagram (page 5).
    Using wire nuts, connect house power wires to
    ventilating fan wires:
    black to black; white to white; green to green;
    Replace the junction box cover.
    CAUTION:Mount junction box cover carefully so that lead
    wires are not pinched. 4. Install the suspension bracket to joists by using long
    screws (M4X30) and secure it to the fan body by
    using screw (M4X10) (Fig. 4)II 3. Install the suspension bracket and the flange of fan
    body to joists by using long screws (M4X30) according
    to Fig. 3.
    7. Install a circular duct and secure it with duct tape
    or clamps.
    2-Long screws
    (M4X30)
    screw (M4X10)II
    Junction box coverConduit
    Wire nut
    Conduit
    Junction box
    Green wires Lead wires
    Circular duct
    Fan body
    Joist
    4-Long screws(M4X30)
    Joist Fan body
    2-Long screws
    (M4X30) Others
    A = 10 1/4~12 inches
    Duct tape
    Fig. 4
    Fig. 5
    Fig. 3-2 Fig. 3-1 
    						
    							inches mm()
    2-Long screws
    (M4X30)Adaptor
    Suspension bracket &IIICeiling joist Adaptor
    2-Long screws
    (M4X30)
    Fig. 8
    B
    A
    7/8 (21.6)13 1/4~15 1/2 ( 336~394 )
    16 1/2~18 3/4 ( 419~480 )
    21 1/4~23 1/2 ( 540~597 )
    8. Finish ceiling work. Ceiling hole should be aligned
    with the edge of the flange. (Fig. 6)
    9. Insert mounting springs into slots as show and
    mount grille to fan body. (Fig. 7)
    8
    Fig. 7
    CeilingSlotMounting spring
    Grille
    1. Open the orifice cover, disconnect plug connector
    from receptacle and remove adaptor from fan body
    before starting installation.
    2. Insert the suspension bracket into the adaptor and
    secure it to joists by using long screws(M4X30) (Fig. 8)
    Keep the distance B (7/8 inch, 21.6mm) for the
    thickness of ceiling board.
    3. Follow steps 5 to 7 of the Installation (page 7) to
    complete the duct work and wiring.I
    If spacing A between joists is 21 1/4 to 23 1/2
    inches, connect suspension bracket and
    (C4 mark to C4 mark) according to page. 8
    Select the suspension bracket according to
    spacing A as show below.II III
    suspension
    bracketsuspension
    bracketIsuspension
    bracketIIIsuspension
    bracket &II III Spacing A
    between Joists
    inches (mm)13 1/4~15 1/2
    ( 336~394 )16 1/2~18 3/4
    ( 419~480 )21 1/4~23 1/2
    ( 540~597 )
    Fig. 6
    Ceiling
    10 7/8(275)
    10 7/8(275)
    inches (mm)
    4. Insert to fan body
    (refering to step 2 of Installation , page 6)the suspension bracket in
    I 
    						
    							Fig. 11
    Fig. 10
    Fig. 9
    When mounting
    body and blower
    separately
    1. Loosen 4 screws (but
    do not remove them
    from blower). (Fig. 12-1)
    2. Remove blower section.
    (Fig. 12-2)
    4. Insert fan body (without
    blower section) into
    joists. (Fig. 9)
    5. Secure the adaptor to
    fan body by using thumb
    screw. (Fig. 10)
    7. Insert the blower into the
    fan body. (Fig. 12-3) 3. Remove adaptor from fan
    body and secure it to
    joists as in Fig. 8 of
    page 8.
    9
    Make sure that adaptor claws are properly inserted
    into body slots.
    IMPORTANT:
    5. Insert the fan body into joists. (Fig. 9)
    6. Open the orifice cover, secure the fan body to
    adaptor by using thumb screw and plug connector
    to receptacle (Fig. 10)
    7. Secure to joists by using
    long screws(M4X30) and secure it to fan body by
    using screw (M4X10) in vertical direction (Fig. 11)the suspension bracket
    II
    8. Follow steps 8 to 9 of Installation (page 8) to
    complete the installation work.I
    6. Secure the fan body
    to joists by using long
    screw(M4X30) (Fig. 11)
    8. Secure the blower.
    (Fig. 12-4) and plug
    connector to receptacle
    (Fig. 10)
    Fan body
    Blower
    Fan body
    Ceiling joist
    Adaptor 4-Screws
    Screw driver4-Screws
    SlotsAdaptor
    claws Fan body Joist
    Conduit
    Junction box cover
    Circular duct
    Duct tape
    Fig. 12-2
    Fig. 12-3
    Fig. 12-1
    Fig. 12-4
    Thumb
    screwPlug connectorReceptacle
    Screw (M4X10)II
    2-Long screws
    (M4X30) 
    						
    							10
    C1
    C2
    C3
    C44 kinds of -joist
    inches (mm)I
    9/16 ( )14.3
    11/16 (17.5)
    31/32 (24.6)
    1 17/32 38.9()
    Suspension bracket
    The suspension can comply with
    different kinds of -joist.III
    III
    I bracket
    1. Before installation, open the orifice cover. Secure the
    fan body to adaptor by using thumb screw. (Fig. 1 of
    page 6)
    2. Connect the suspension to fan body. (Fig. 13)
    (Select the hole by checking joist size fix the screw
    to the frame hole.)bracketIII
    I-
    3. Connect the ventilating fan to the joist. (Fig. 14)I-
    4. Follow steps 5 to 9 of installation (page 7, page 8) to
    complete the installation work.I
    2. Insert the suspension bracket into the bracket cover of
    adaptor side and the back of the fan body. (Fig.15)
    (select the suspension bracket according to spacing A
    as show below)
    1. Before installation, open the orifice cover. Secure the
    fan body to adaptor by using thumb screw. (Fig.1 of
    page 6)
    Fig. 13
    Fig. 14
    Screw (M4X10)II Suspension
    bracketIII
    4-Long screws
    (M4X30) IjoistC
    C3
    C4
    C1
    C2
    Suspension bracketI
    Suspension bracketIIISuspension bracketII
    A = 16 inches and 19.2 inches horizontal joist
    16 inches and 19.2
    inches horizontal joist
    and
    19.2 inches vertical joist
    Suspension bracketIII
    A = 19.2 inches vertical joist
    Suspension bracketIISuspension bracketI
    Fig.15-2
    Fig.15-1
    A 
    						
    All Panasonic manuals Comments (0)