Panasonic Ventilation Fan Fv 05vf2 Installation Instructions
Have a look at the manual Panasonic Ventilation Fan Fv 05vf2 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Ventilating FanFV-05VF2 FV-08VF2 FV-11VF2 READ AND SAVE THESE INSTRUCTIONS.R Please readthese instructionscarefullybeforeattempting toinstall, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference. SpecificationsDimensions Description Table of Contents Supplied Accessories Unpacking General Safety Information Wiring Diagram4 4-54 32 2 5 12 12 13 14 8-9 Installation( Wooden Header ) 10( -Joist Mounting )I 10-11Installation ( Between Joist Mounting ) Installation( In Existing Construction )VIV Installation( Joist Mounting- )II Installation Maintenance Practical Guide to Installation 14Product Service 6-8IInstallation( Joist Mounting- )I II III IV
FV-05VF2 FV-08VF2 FV-11VF2 These Panasonic ceiling mount ventilating fan models use a sirocco fan with dolphin-shaped blades driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. Double orifice technology is used to reduce noise. It also incorporates a thermal-cutoff for safety. The grille covering the main body is a spring-loaded, quickremove type. A damper for preventing counterflow is provided. 1 81Thumb screwLong screw (M4X30)Quantity Appearance Part name Grille Suspension bracketI Suspension bracketII 1 1 Screw (M4X8)I2 1Suspension bracketIII Screw (M4X10)II2 3 inches adaptor connector (optional part) 1
Unit: ( )inches mm Damper Body Adaptor Grille Part name Part name No. No. 1 2 3 4 67 8 Suspension bracket Orifice Orifice cover Bracket cover 59 10 Junction box Adaptor connector 11 12 Motor Blade (For 16 inches on center joists, only use suspension bracket , for 19.2 inches on center joists, only use suspension bracket , If more than 19.2 inches on center,use suspension bracket & .)I III II III FV-05VF2 FV-08VF2 FV-11VF2 6 1 24 37/8 98() 3 43/8 110() 5 5/8 (141) 9 10 3 1/4 (81) 1 3/4 (43.5) 2 15/16 (74) 5 11 12 13 330() 10 1/4 261() 16 1/8 (410) 1 (25) 78 14 37/8 98() 33 5/8 (92)1(25) 43/8 110() 5 5/8 (141) 9 10 3 1/4 (81) 1 3/4 (43.5) 10 1/4 259() 11 7/8 (301) 2 15/16 (74) 5 11 12 13 330() 10 1/4 261() 16 1/8 (410) 1 (25) 78 13 1/4~15 1/2 ( 336~394 ) 16 1/2~18 3/4 ( 419~480 ) 21 1/4~23 1/2 ( 540~597 ) 1 (25) 10 1/4 259() 11 7/8 (301)13 1/4~15 1/2 ( 336~394 ) 16 1/2~18 3/4 ( 419~480 ) 21 1/4~23 1/2 ( 540~597 ) 3 5/8 (92)
Specifications are based on HVI standard. Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. 1. Do not install this ventilating fan where air temperature may exceed 40 C (104 F).oo 2. Make certain that the electric service supply voltage is 120V, 60 Hz. 3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). 4. Always disconnect the power source before working on or near the fan, motor or junction box. 5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects. 6. Do not kink the power cord. 7. Do not install the unit where ducts are configured as shown in Fig. A. 8. Provide suction parts with proper ventilation. 9. This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit. 24 Hz 60 V Air direction Model No. FV-05VF2 FV-08VF2 FV-11VF2 Exhaust120 (W) Power consumption 15 33 Speed (rpm)Air deliver (cfm) 3.5 (7.7) 3.7 (8.2) 3.8 (8.4) Weight kg(Ib.) Duct diameter (inches) 4 4 4 Noise (sone) Adaptor Fig. A 50 80 11 0 635 755 830 0.8 1.50.4 15 350 7400.5 24 3 70 8450.8 33 3 90 12301.5
Power Supply AC120V 60Hz Fan unit Red Capacitor White Black Green Earth groundJunction box GreenNeutral Live Earth CAUTION: 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. Not for use in cooking area. (Fig. B) 3. This product must be properly grounded.Floor Do not install above or(Cooking area) inside this area 45o45o equipmentCooking Fig. B WARNING: To reduce the risk of fire, electric shock or injury to persons, observe the following; A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. E. Ducted fans must always be vented to the outdoors. F. These models are UL listed for tub and shower enclosures. G. Solid state controls may cause harmonic distortion which can cause motor humming noise. Do not use this unit with any solid-state control device. H. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. I. NEVER place a switch where it can be reached from a tub or shower. J. Not to be installed in a ceiling thermally insulated to a value greater than R40.
Press and hold the claw of orifice cover to open the orifice cover. 1. Before installation, open the orifice cover. Secure the fan body to adaptor by using thumb screw. (Fig. 1) Fig. 1 2. Insert the supension bracket into the fan body and adaptor. (select the suspension bracket acc rding to Fig. 2)o Remove the tape IMPORTANT: Adaptor Remove the tape from damper and adaptor before installation.As show below: Damper 2-Screw (M4X8)I Suspension bracketIIISuspension bracketII If spacing A on center joists is 24 inches, connect suspension bracket and (C4 mark to C4 mark) as show below :II III Orifice cover Claw 3 inches adaptor connector Connection method for 3 inches adaptor connector Duct tape Orifice cover Fan body Thumb screw Suspension bracketIII Suspension bracketI Fig. 2-3 A = 19.2 inches vertical joists Fan body Suspension bracketI Fig. 2-1Fan body A = 12 inches Suspension bracketISuspension bracketIII Fig. 2-2 A = 16 inches Fan body Fig. 2-4Fan body Suspension bracketI Suspension bracketIII Suspension bracketII A = 24 inches 2 1 12 3 Joist A
5. Remove junction box cover and secure conduit or stress relief to junction box knock-out hole. (Fig. 5) 6. Refer to wiring diagram (page 5). Using wire nuts, connect house power wires to ventilating fan wires: black to black; white to white; green to green; Replace the junction box cover. CAUTION:Mount junction box cover carefully so that lead wires are not pinched. 4. Install the suspension bracket to joists by using long screws (M4X30) and secure it to the fan body by using screw (M4X10) (Fig. 4)II 3. Install the suspension bracket and the flange of fan body to joists by using long screws (M4X30) according to Fig. 3. 7. Install a circular duct and secure it with duct tape or clamps. 2-Long screws (M4X30) screw (M4X10)II Junction box coverConduit Wire nut Conduit Junction box Green wires Lead wires Circular duct Fan body Joist 4-Long screws(M4X30) Joist Fan body 2-Long screws (M4X30) Others A = 10 1/4~12 inches Duct tape Fig. 4 Fig. 5 Fig. 3-2 Fig. 3-1
inches mm() 2-Long screws (M4X30)Adaptor Suspension bracket &IIICeiling joist Adaptor 2-Long screws (M4X30) Fig. 8 B A 7/8 (21.6)13 1/4~15 1/2 ( 336~394 ) 16 1/2~18 3/4 ( 419~480 ) 21 1/4~23 1/2 ( 540~597 ) 8. Finish ceiling work. Ceiling hole should be aligned with the edge of the flange. (Fig. 6) 9. Insert mounting springs into slots as show and mount grille to fan body. (Fig. 7) 8 Fig. 7 CeilingSlotMounting spring Grille 1. Open the orifice cover, disconnect plug connector from receptacle and remove adaptor from fan body before starting installation. 2. Insert the suspension bracket into the adaptor and secure it to joists by using long screws(M4X30) (Fig. 8) Keep the distance B (7/8 inch, 21.6mm) for the thickness of ceiling board. 3. Follow steps 5 to 7 of the Installation (page 7) to complete the duct work and wiring.I If spacing A between joists is 21 1/4 to 23 1/2 inches, connect suspension bracket and (C4 mark to C4 mark) according to page. 8 Select the suspension bracket according to spacing A as show below.II III suspension bracketsuspension bracketIsuspension bracketIIIsuspension bracket &II III Spacing A between Joists inches (mm)13 1/4~15 1/2 ( 336~394 )16 1/2~18 3/4 ( 419~480 )21 1/4~23 1/2 ( 540~597 ) Fig. 6 Ceiling 10 7/8(275) 10 7/8(275) inches (mm) 4. Insert to fan body (refering to step 2 of Installation , page 6)the suspension bracket in I
Fig. 11 Fig. 10 Fig. 9 When mounting body and blower separately 1. Loosen 4 screws (but do not remove them from blower). (Fig. 12-1) 2. Remove blower section. (Fig. 12-2) 4. Insert fan body (without blower section) into joists. (Fig. 9) 5. Secure the adaptor to fan body by using thumb screw. (Fig. 10) 7. Insert the blower into the fan body. (Fig. 12-3) 3. Remove adaptor from fan body and secure it to joists as in Fig. 8 of page 8. 9 Make sure that adaptor claws are properly inserted into body slots. IMPORTANT: 5. Insert the fan body into joists. (Fig. 9) 6. Open the orifice cover, secure the fan body to adaptor by using thumb screw and plug connector to receptacle (Fig. 10) 7. Secure to joists by using long screws(M4X30) and secure it to fan body by using screw (M4X10) in vertical direction (Fig. 11)the suspension bracket II 8. Follow steps 8 to 9 of Installation (page 8) to complete the installation work.I 6. Secure the fan body to joists by using long screw(M4X30) (Fig. 11) 8. Secure the blower. (Fig. 12-4) and plug connector to receptacle (Fig. 10) Fan body Blower Fan body Ceiling joist Adaptor 4-Screws Screw driver4-Screws SlotsAdaptor claws Fan body Joist Conduit Junction box cover Circular duct Duct tape Fig. 12-2 Fig. 12-3 Fig. 12-1 Fig. 12-4 Thumb screwPlug connectorReceptacle Screw (M4X10)II 2-Long screws (M4X30)
10 C1 C2 C3 C44 kinds of -joist inches (mm)I 9/16 ( )14.3 11/16 (17.5) 31/32 (24.6) 1 17/32 38.9() Suspension bracket The suspension can comply with different kinds of -joist.III III I bracket 1. Before installation, open the orifice cover. Secure the fan body to adaptor by using thumb screw. (Fig. 1 of page 6) 2. Connect the suspension to fan body. (Fig. 13) (Select the hole by checking joist size fix the screw to the frame hole.)bracketIII I- 3. Connect the ventilating fan to the joist. (Fig. 14)I- 4. Follow steps 5 to 9 of installation (page 7, page 8) to complete the installation work.I 2. Insert the suspension bracket into the bracket cover of adaptor side and the back of the fan body. (Fig.15) (select the suspension bracket according to spacing A as show below) 1. Before installation, open the orifice cover. Secure the fan body to adaptor by using thumb screw. (Fig.1 of page 6) Fig. 13 Fig. 14 Screw (M4X10)II Suspension bracketIII 4-Long screws (M4X30) IjoistC C3 C4 C1 C2 Suspension bracketI Suspension bracketIIISuspension bracketII A = 16 inches and 19.2 inches horizontal joist 16 inches and 19.2 inches horizontal joist and 19.2 inches vertical joist Suspension bracketIII A = 19.2 inches vertical joist Suspension bracketIISuspension bracketI Fig.15-2 Fig.15-1 A