Have a look at the manual Panasonic Ventilating Fan FV-08VKML2, FV-08VKSL2 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
(FV-08VKML2) (FV-08VKSL2) Fig.8 Fig.9 Fig.10 Circularduct Conduit Inches(mm) Joist Junctionboxcover INSTALLATION(JOISTMOUNTING-) (Whenspacingthefanbodyflangebelowthedrywallorresilientchannel) 1.Removethemachinescrewbyusingscrewdriver, disconnectplugconnectorfromreceptacleand removeadaptorfromfanbodybeforeinstallation, (Fig.8) 4.Insertthesuspensionbracketintofanbody(refering tostep1ofinstallation,page8) I 5.Insertthefanbodyintojoists.(Fig.10) IMPORTANT: Makesurethatadaptorclawsareproperlyinserted intofanbodyslots. 2.Insertthesuspensionbracketintotheadaptorand secureittojoistsbyusinglongscrews(ST4.2X20)(Fig.9) KeepthedistanceB(1/inch,12.7mmor5/8inch, 15.9mm)forthethicknessofceilingboard. 2 SpacingA betweenJoists inches(mm) Suspension bracket Suspension bracket I Suspension bracket III Suspension bracket IIIII IfspacingAbetweenjoistsis211/4to231/ inches(540to597mm),connectsuspension bracketand(C4marktoC4mark)according topage.8Selectthesuspensionbracket accordingtospacingAasshownbelow: IIIII 2 131/4151/ (336394) ~ ~ 2 161/183/4 (419) ~ ~480 2 211/4231/ (540597) ~ ~ 2 Machinescrew Screwdriver Fanbody Fanbody Slots Adaptor claws Gloves Gloves Gloves Gloves Adaptor Adaptor 2Longscrews (ST4.2X20) 2Longscrews (ST4.2X20) JoistsSuspension bracket I Suspensionbracket 161/2183/4(419480)~~ 131/4151/2(336394) ~~ 211/4231/2(540597) ~~ 1/(12.7) 2 5/8(15.9) 11 Receptacle Receptacle plug connector plugconnector PDF created with pdfFactory Pro trial version www.pdffactory.com
(FV-08VKML2) (FV-08VKSL2) Screwdriver Screw(ST4.2X12) II 2Longscrews (ST4.2X20) Screw(ST4.2X12)II 2Longscrews (ST4.2X20) 4Longscrews(ST4.2X20) Machinescrew Plugconnector Receptacle Fig.11 Fig.12 Fig.13 Fig.14 I -joist Suspension bracket III INSTALLATION(JOISTMOUNTING-)CONTINUED INSTALLATION(-JOISTMOUNTING) 6.Securethefanbodytoadaptorbyusingmachine screwandplugconnectortoreceptacle(Fig.11) 7.Securethesuspensionbrackettojoistsbyusing longscrews(ST4.2X20)andsecureittofanbodyby usingscrew(ST4.2X12)inverticaldirection(Fig.12) II 8.Followsteps7to12ofInstallation(page10)to completetheinstallationwork. I C1 C2 C3 C4 Suspensionbracket Thesuspensionbracketcancomplywith differentkindof-joists. III III I 1.Beforeinstallation,securethelightingunittofanbody (referingtoFig.5ofpage10). 2.Connectthesuspensionbrackettofanbody.(Fig.13) (Selecttheholebychecking-joistsizeandfixthe screwtotheframehole.) III Ⅰ 3.Connectthefanbodytothe-joist.(Fig.14) Ⅰ 4.Followsteps4to12ofinstallation(page9,page10)to completetheinstallationwork. I 12 4kindsof-joist inches(mm) Ⅰ 9/16(14.3) C1 C2 C3 C4 11/16(17.5) 31/32(24.6) 117/32(38.9) hole mark PDF created with pdfFactory Pro trial version www.pdffactory.com
INSTALLATION(SUSPENDEDBETWEENJOISTMOUNTING) 1.Beforeinstallation,securethelightingunittofanbody (referingtoFig.5ofpage10). 2.Insertthesuspensionbracketintobracketcoverof adaptorsideandthebackofthefanbody. (Fig.15-1,15-2) (selectthesuspensionbracketaccordingtospacingAasshownbelow.) 16inchesand19.2incheshorizontaljoist Suspensionbracket I SuspensionbracketI Suspensionbracket III Suspensionbracket III Suspensionbracket II Suspensionbracket II16inchesand19.2inches horizontaljoist 19.2inchesverticaljoist Fig.15-1 Fig.15-2 Fig.16 Fig.17 Fig.18 Joist 2Longscrews(ST4.2X20) 4Longscrews(ST4.2X20) 2Screw (ST4.2X12) II Joists Adaptor Junctionbox Fanbody 5/8(15.9) 3.Insertthefanbodybetweenjoists.Makesurethefan bodyislevelandsquare(perpendicular)withthejoists. (Fig.16) Ifinstallingwithfanbodyflangebelowdrywall,keep thedistanceB(1/inch,12.7mmor5/8inch,15.9mm) forthethicknessofceilingboard. 2 4.Securethesuspensionbrackettojoistsbyusinglong screws(ST4.2X20)(Fig.17,Fig.18) 5.Securethesuspensionbrackettofanbodybyusing screw(ST4.2X12)(Fig.18) II 6.Followsteps4to12ofinstallation(page9,page10) tocompletetheinstallationwork. I 13 Inches(mm) 131/4153/4(336400) ~~ 161/2183/4(419480) ~~ 35(76126) 54/574/5(148198) ~~ ~~ 1/2(12.7) PDF created with pdfFactory Pro trial version www.pdffactory.com
INSTALLATION(WOODENHEADER) INSTALLATION(INEXISTINGCONSTRUCTION) 1.Beforeinstallation,securethelightingunittofanbody (referingtoFig.5ofpage10). 2.Installheaderbetweenjoistsbyusingnailsorscrews. 1.Installationinexistingconstruction. Installingthefanbodyinanexistingbuildingrequiresanaccessiblearea(atticorcrawlspace)above theplannedinstallationlocationorexistingductingandwiring. 2.Installationfromaccessibleareaabovefanlocation. (1)Inspectductworkandwiringbeforeproceedingwithinstallation. (2)Removeceilingsection. (3)Installfanbodyfromabovewithfanbodyflangeflushtodrywallceiling. 3.Installthefanbodyandsecureitbyusinglong screws(ST4.2X20)(Fig.19,Fig.20) 4.Followsteps4to12ofinstallation(page9,page10) tocompletetheinstallationwork. I Joist Joist Adaptor Adaptor Circularduct 6Longscrews (ST4.2X20) Fig.20 Header Fanbody Inches(mm) (1)Toinstallthefanbody,followtheproceduresdescribedinInstallation.Takethefollowing precautionsbeforeinstallation. II (2)Inspectductworkandwiringbeforeproceedingwithinstallation. (3)Plansuitablelocationforfanbody.(Nexttoceilingjoist) (4)Beforeinstallation,provideinspectionandmaintenanceaccessatalocationthatwillnotinterfere withinstallationworkshownininstallation. (5)First,removeceilingsection. (6)Installfanbody. II CAUTION: Checkareaaboveplannedinstallationlocationtobesurethat: 1.Ductworkcanbedoneandthatareaissufficientforproperventilation. 2.Wiringcanberuntoplanninglocation. 3.Nowiringorotherobstructionsshallinterferewithinstallation. 14Fig.19 PDF created with pdfFactory Pro trial version www.pdffactory.com
MAINTENANCE(CLEANING) I WARNING: 1.Removegrillepulldownonemountingspring.Remove sensorunitthenpulldowntheothermountingspring. (Squeezemountingspringandpulldowncarefully.) (Fig.21-1,21-2) 2.Washandcleangrille.(Usenon-abrasivekitchendetergent, wipedrywithnewcloth.)(Fig.22) 3.Thegrilleshouldbedryaftercleaning.(Fig.23) 4.Removedustanddirtfromfanbodyusingavacuum cleaner.(Fig.24) 5.Usingaclothdampenedwithkitchendetergent,remove anydirtfromfanbody.Wipedrywithnewcloth.(Fig.25) 6.Replacegrille. CAUTION: 1.Neverusegasoline,benzene,thinneroranyother suchchemicalsforcleaningtheventilatingfan. 2.Donotallowwatertogetintothemotor. 3.Donotsoakresinpartsinwaterover140F(60C). WARNING: 1.Disconnectpowersourcebeforeworkingonunit. 2.Thelampsglassisfragile.Pleasehandlewithcare.Toremovelamp,graspatbaseandmoveback andforcetoloosen.Donotpullhardonthelamporyoumaybreaktheglass. 3.4Wnightlamphasthreadedbase.Removebyturningcounterclockwise. 4.Besuretoremovethenightlampbeforeremovefluorescentlamps. Disconnectpowersourcebeforeworkingonunit.Routine maintenancemustbedoneeveryyear. Ceiling Ceiling Grille Grille Gloves Gloves Gloves Gloves Sensorunit Fig.21-1 Fig.21-2 Fig.22 Fig.25 Fig.23 Fig.24 Vacuumcleaner Mountingspring MAINTENANCE(REPLACEMENTOFLAMP) II 15 PDF created with pdfFactory Pro trial version www.pdffactory.com
A0809-008VKML220 MAINTENANCE(REPLACEMENTOFLAMP)CONTINUED II PRACTICALGUIDETOINSTALLATION PRODUCTSERVICE PANASONICCONSUMERELECTRONICSCOMPANY PANASONICCANADAINC. 1.Removegrille.(Squeezemountingspringandpull down)(Fig.21-1,21-2ofpage15) 2.Removethe4Wnightlamp.(Fig.26) Properinsulatetheareaaroundthefan tominimizebuildingheatlossandgain. (Fig.28) Properinsulatetheareaaroundthefan tominimizebuildingheatlossandgain. (Fig.28) Fourinchorsixinchroofjack,wallcap, orsoffitventwithbackdraftdamper. Caulkterminationtoduct. Shortpieceofflexibleduct helpsalignmentandabsorbs sound.Clampsplustapeat allflexjoints. 2-3ftstraightrunbeforeelbow. Inatticinstallation, caulkboxtodrywall. Foiltapetightlycoversallmetal ductjoints(gluePVCjoints). Loosefillorbattinsulationcanbeplaced directlyoverthefanhousingintheattic. Panasonicfansandfan/lightcombination unitsdonotcreateexcessiveheatthatis acommonproblemwithrecessedlight fixturesorsomecompetitorsfan/light combinations.Ourefficient,cool-running motorsandourfluorescentlampsdonot createenoughambientheattobesubjected totheselimitations. 3.Changethefluorescentlamps(PanasonicFDS 18E27/4,18WorFDS18E35/4,18WorFDS18E42/4, 18W)orthe4Wnightlamp,connecttheplug connectorandreplacethegrille.(Fig.27) II Fig.26 Fig.27 Fig.28 Insulation. WarningConcerningRemovalofCovers. DivisionofPanasonicCorporationofNorthAmerica, OnePanasonicWay,Secaucus,NJ07094 www.panasonic.com www.panasonic.ca5770AmblerDrive,Mississauga,ONL4W2T3 Theunitshouldbeservicedbyqualifiedtechniciansonly.Noserviceinformationisprovidedforcustomers. Yourproductisdesignedandmanufacturedtoensureaminimumofmaintenance.However,shouldyour uniteverrequireservice,anationwidesystemoffactoryservicecentersandAUTHORIZEDINDEPENDENT SERVICECENTERSismaintainedtosupportyourproductswarranty. (IntheU.S.A.,Call1-866-292-7292toCustomercallCenter.) PDF created with pdfFactory Pro trial version www.pdffactory.com