    Have a look at the manual Panasonic Ventilating Fan FV-08VKML2, FV-08VKSL2 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							(FV-08VKML2)
    (FV-08VKSL2) Fig.8
    Fig.9
    Fig.10
    Circularduct
    Conduit
    Inches(mm)
    Joist Junctionboxcover INSTALLATION(JOISTMOUNTING-)
    (Whenspacingthefanbodyflangebelowthedrywallorresilientchannel)
    1.Removethemachinescrewbyusingscrewdriver, disconnectplugconnectorfromreceptacleand
    removeadaptorfromfanbodybeforeinstallation,
    (Fig.8)
    4.Insertthesuspensionbracketintofanbody(refering tostep1ofinstallation,page8) I
    5.Insertthefanbodyintojoists.(Fig.10) IMPORTANT:
    Makesurethatadaptorclawsareproperlyinserted
    intofanbodyslots.
    2.Insertthesuspensionbracketintotheadaptorand
    secureittojoistsbyusinglongscrews(ST4.2X20)(Fig.9)
    KeepthedistanceB(1/inch,12.7mmor5/8inch,
    15.9mm)forthethicknessofceilingboard. 2
    SpacingA
    betweenJoists
    inches(mm) Suspension
    bracket Suspension
    bracket
    I Suspension
    bracket
    III Suspension
    bracket
    IIIII
    IfspacingAbetweenjoistsis211/4to231/
    inches(540to597mm),connectsuspension
    bracketand(C4marktoC4mark)according
    topage.8Selectthesuspensionbracket
    accordingtospacingAasshownbelow: IIIII 2
    131/4151/ (336394) ~
    ~ 2
    161/183/4
    (419) ~
    ~480
    2
    211/4231/
    (540597) ~
    ~ 2 Machinescrew
    Screwdriver Fanbody
    Fanbody
    Slots Adaptor
    claws
    Gloves
    Gloves Gloves
    Gloves Adaptor
    Adaptor
    2Longscrews
    (ST4.2X20)
    2Longscrews
    (ST4.2X20) JoistsSuspension
    bracket
    I
    Suspensionbracket 161/2183/4(419480)~~
    131/4151/2(336394)
    ~~
    211/4231/2(540597) ~~
    1/(12.7) 2
    5/8(15.9)
    11 Receptacle
    Receptacle plug
    connector
    plugconnector
    PDF created with pdfFactory Pro trial version 
    www.pdffactory.com 
    						
    							(FV-08VKML2)
    (FV-08VKSL2)
    Screwdriver
    Screw(ST4.2X12) II
    2Longscrews
    (ST4.2X20)
    Screw(ST4.2X12)II
    2Longscrews
    (ST4.2X20)
    4Longscrews(ST4.2X20)
    Machinescrew
    Plugconnector Receptacle
    Fig.11
    Fig.12
    Fig.13
    Fig.14
    I
    -joist Suspension
    bracket
    III INSTALLATION(JOISTMOUNTING-)CONTINUED
    INSTALLATION(-JOISTMOUNTING)
    6.Securethefanbodytoadaptorbyusingmachine
    screwandplugconnectortoreceptacle(Fig.11)
    7.Securethesuspensionbrackettojoistsbyusing longscrews(ST4.2X20)andsecureittofanbodyby
    usingscrew(ST4.2X12)inverticaldirection(Fig.12) II
    8.Followsteps7to12ofInstallation(page10)to completetheinstallationwork. I
    C1
    C2
    C3
    C4
    Suspensionbracket
    Thesuspensionbracketcancomplywith
    differentkindof-joists. III
    III
    I
    1.Beforeinstallation,securethelightingunittofanbody (referingtoFig.5ofpage10).
    2.Connectthesuspensionbrackettofanbody.(Fig.13) (Selecttheholebychecking-joistsizeandfixthe
    screwtotheframehole.) III
    Ⅰ
    3.Connectthefanbodytothe-joist.(Fig.14) Ⅰ
    4.Followsteps4to12ofinstallation(page9,page10)to completetheinstallationwork. I
    12
    4kindsof-joist
    inches(mm) Ⅰ
    9/16(14.3) C1
    C2
    C3 C4
    11/16(17.5)
    31/32(24.6)
    117/32(38.9) hole
    mark
    PDF created with pdfFactory Pro trial version 
    www.pdffactory.com 
    						
    							INSTALLATION(SUSPENDEDBETWEENJOISTMOUNTING)
    1.Beforeinstallation,securethelightingunittofanbody (referingtoFig.5ofpage10).
    2.Insertthesuspensionbracketintobracketcoverof adaptorsideandthebackofthefanbody.
    (Fig.15-1,15-2)
    (selectthesuspensionbracketaccordingtospacingAasshownbelow.)
    16inchesand19.2incheshorizontaljoist Suspensionbracket
    I
    SuspensionbracketI
    Suspensionbracket
    III
    Suspensionbracket III Suspensionbracket
    II
    Suspensionbracket II16inchesand19.2inches
    horizontaljoist
    19.2inchesverticaljoist Fig.15-1
    Fig.15-2
    Fig.16
    Fig.17
    Fig.18
    Joist
    2Longscrews(ST4.2X20)
    4Longscrews(ST4.2X20)
    2Screw
    (ST4.2X12) II Joists
    Adaptor
    Junctionbox
    Fanbody
    5/8(15.9)
    3.Insertthefanbodybetweenjoists.Makesurethefan
    bodyislevelandsquare(perpendicular)withthejoists.
    (Fig.16)
    Ifinstallingwithfanbodyflangebelowdrywall,keep
    thedistanceB(1/inch,12.7mmor5/8inch,15.9mm)
    forthethicknessofceilingboard. 2
    4.Securethesuspensionbrackettojoistsbyusinglong screws(ST4.2X20)(Fig.17,Fig.18)
    5.Securethesuspensionbrackettofanbodybyusing screw(ST4.2X12)(Fig.18) II
    6.Followsteps4to12ofinstallation(page9,page10) tocompletetheinstallationwork. I
    13 Inches(mm)
    131/4153/4(336400)
    ~~
    161/2183/4(419480) ~~
    35(76126)
    54/574/5(148198) ~~
    ~~
    1/2(12.7)
    PDF created with pdfFactory Pro trial version  www.pdffactory.com 
    						
    							INSTALLATION(WOODENHEADER)
    INSTALLATION(INEXISTINGCONSTRUCTION)
    1.Beforeinstallation,securethelightingunittofanbody
    (referingtoFig.5ofpage10).
    2.Installheaderbetweenjoistsbyusingnailsorscrews.
    1.Installationinexistingconstruction. Installingthefanbodyinanexistingbuildingrequiresanaccessiblearea(atticorcrawlspace)above
    theplannedinstallationlocationorexistingductingandwiring.
    2.Installationfromaccessibleareaabovefanlocation. (1)Inspectductworkandwiringbeforeproceedingwithinstallation.
    (2)Removeceilingsection.
    (3)Installfanbodyfromabovewithfanbodyflangeflushtodrywallceiling.
    3.Installthefanbodyandsecureitbyusinglong
    screws(ST4.2X20)(Fig.19,Fig.20)
    4.Followsteps4to12ofinstallation(page9,page10) tocompletetheinstallationwork. I Joist
    Joist
    Adaptor
    Adaptor Circularduct
    6Longscrews
    (ST4.2X20) Fig.20
    Header
    Fanbody
    Inches(mm)
    (1)Toinstallthefanbody,followtheproceduresdescribedinInstallation.Takethefollowing precautionsbeforeinstallation. II
    (2)Inspectductworkandwiringbeforeproceedingwithinstallation.
    (3)Plansuitablelocationforfanbody.(Nexttoceilingjoist)
    (4)Beforeinstallation,provideinspectionandmaintenanceaccessatalocationthatwillnotinterfere withinstallationworkshownininstallation.
    (5)First,removeceilingsection.
    (6)Installfanbody. II
    CAUTION:
    Checkareaaboveplannedinstallationlocationtobesurethat:
    1.Ductworkcanbedoneandthatareaissufficientforproperventilation.
    2.Wiringcanberuntoplanninglocation.
    3.Nowiringorotherobstructionsshallinterferewithinstallation.
    14Fig.19
    PDF created with pdfFactory Pro trial version 
    www.pdffactory.com 
    						
    							MAINTENANCE(CLEANING)
    I
    WARNING:
    1.Removegrillepulldownonemountingspring.Remove sensorunitthenpulldowntheothermountingspring.
    (Squeezemountingspringandpulldowncarefully.)
    (Fig.21-1,21-2)
    2.Washandcleangrille.(Usenon-abrasivekitchendetergent, wipedrywithnewcloth.)(Fig.22)
    3.Thegrilleshouldbedryaftercleaning.(Fig.23)
    4.Removedustanddirtfromfanbodyusingavacuum cleaner.(Fig.24)
    5.Usingaclothdampenedwithkitchendetergent,remove anydirtfromfanbody.Wipedrywithnewcloth.(Fig.25)
    6.Replacegrille. CAUTION:
    1.Neverusegasoline,benzene,thinneroranyother
    suchchemicalsforcleaningtheventilatingfan.
    2.Donotallowwatertogetintothemotor.
    3.Donotsoakresinpartsinwaterover140F(60C).
    WARNING:
    1.Disconnectpowersourcebeforeworkingonunit.
    2.Thelampsglassisfragile.Pleasehandlewithcare.Toremovelamp,graspatbaseandmoveback andforcetoloosen.Donotpullhardonthelamporyoumaybreaktheglass.
    3.4Wnightlamphasthreadedbase.Removebyturningcounterclockwise.
    4.Besuretoremovethenightlampbeforeremovefluorescentlamps. Disconnectpowersourcebeforeworkingonunit.Routine
    maintenancemustbedoneeveryyear. Ceiling
    Ceiling Grille
    Grille Gloves
    Gloves
    Gloves
    Gloves Sensorunit
    Fig.21-1
    Fig.21-2
    Fig.22
    Fig.25 Fig.23
    Fig.24
    Vacuumcleaner Mountingspring
    MAINTENANCE(REPLACEMENTOFLAMP) II
    15
    PDF created with pdfFactory Pro trial version  www.pdffactory.com 
    						
    							A0809-008VKML220
    MAINTENANCE(REPLACEMENTOFLAMP)CONTINUED
    II
    PRACTICALGUIDETOINSTALLATION
    PRODUCTSERVICE
    PANASONICCONSUMERELECTRONICSCOMPANY
    PANASONICCANADAINC.
    1.Removegrille.(Squeezemountingspringandpull
    down)(Fig.21-1,21-2ofpage15)
    2.Removethe4Wnightlamp.(Fig.26)
    Properinsulatetheareaaroundthefan
    tominimizebuildingheatlossandgain.
    (Fig.28) Properinsulatetheareaaroundthefan
    tominimizebuildingheatlossandgain.
    (Fig.28) Fourinchorsixinchroofjack,wallcap,
    orsoffitventwithbackdraftdamper.
    Caulkterminationtoduct.
    Shortpieceofflexibleduct
    helpsalignmentandabsorbs
    sound.Clampsplustapeat
    allflexjoints.
    2-3ftstraightrunbeforeelbow.
    Inatticinstallation,
    caulkboxtodrywall.
    Foiltapetightlycoversallmetal
    ductjoints(gluePVCjoints).
    Loosefillorbattinsulationcanbeplaced
    directlyoverthefanhousingintheattic.
    Panasonicfansandfan/lightcombination
    unitsdonotcreateexcessiveheatthatis
    acommonproblemwithrecessedlight
    fixturesorsomecompetitorsfan/light
    combinations.Ourefficient,cool-running
    motorsandourfluorescentlampsdonot
    createenoughambientheattobesubjected
    totheselimitations. 3.Changethefluorescentlamps(PanasonicFDS
    18E27/4,18WorFDS18E35/4,18WorFDS18E42/4,
    18W)orthe4Wnightlamp,connecttheplug
    connectorandreplacethegrille.(Fig.27) II Fig.26
    Fig.27
    Fig.28
    Insulation.
    WarningConcerningRemovalofCovers.
    DivisionofPanasonicCorporationofNorthAmerica,
    OnePanasonicWay,Secaucus,NJ07094
    www.panasonic.com www.panasonic.ca5770AmblerDrive,Mississauga,ONL4W2T3 Theunitshouldbeservicedbyqualifiedtechniciansonly.Noserviceinformationisprovidedforcustomers.
    Yourproductisdesignedandmanufacturedtoensureaminimumofmaintenance.However,shouldyour
    uniteverrequireservice,anationwidesystemoffactoryservicecentersandAUTHORIZEDINDEPENDENT
    SERVICECENTERSismaintainedtosupportyourproductswarranty.
    (IntheU.S.A.,Call1-866-292-7292toCustomercallCenter.)
    PDF created with pdfFactory Pro trial version  www.pdffactory.com 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Ventilating Fan FV-08VKML2, FV-08VKSL2 Installation Instructions