Home
>
Panasonic
>
Ventilation
>
Panasonic Ventilating Fan FV-08VKML2, FV-08VKSL2 Installation Instructions
Panasonic Ventilating Fan FV-08VKML2, FV-08VKSL2 Installation Instructions
Have a look at the manual Panasonic Ventilating Fan FV-08VKML2, FV-08VKSL2 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
VentilatingFan INSTALLATIONINSTRUCTIONS ModelNo. FV-08VKML2 FV-08VKSL2 FV-08VKML2 FV-08VKSL2 READANDSAVETHESEINSTRUCTIONS. ThankyouverymuchforhavingpurchasedourVentilatingFan Pleasereadtheseinstructionscarefullybeforeattemptingtoinstall, operateorservicethePanasonicVentilatingFan.Failuretocomply withinstructionscouldresultinpersonalinjuryand/orproperty damage.Pleaseretainthisbookletforfuturereference. TableofContents PleaseReadPriorToInstallingThisFan Unpacking SuppliedAccessories Description Dimensions WiringDiagram SwitchIndication Operation Specifications GeneralSafetyInformation Maintenance PracticalGuideToInstallation ProductService Installation(SuspendedBetweenJoistMounting) Installation(WoodenHeader) Installation(InExistingConstruction) Installation(JoistMounting-) Installation(JoistMounting-) Installation(-JoistMounting) . 2 3 3 3 4 5 56 6 7 8-10 11-12 12 13 1414 15-16 16 16 II III I I I I I II PDF created with pdfFactory Pro trial version www.pdffactory.com
PLEASEREADPRIORTOINSTALLINGTHISFAN TheWhisperGreenlineofventilatingfansemploysstateofthearttechnology providinganumberofuniquefeaturesthatleadtoimprovedindoorairquality. Thesefeaturesneedtobefullyunderstoodpriortoinstallationtofullyrealizethe benefitsthefansoffer. Thesefansaredesignedtoruncontinuously ensuringahealthyenvironmentatlowCFMlevels24hoursaday.Byutilizing apre-setlowerlevel(0,30,40,50,60,70CFM).Thesettingisdependentonthe sizeoftheroomandtheindividualwishesofthehomeowner. (Sq.feet) TwoBedroomsThreeBedrooms FourBedroomsFiveBedrooms < 1,000 33 40 48 55 60 53 45 38 1,500 2,000 43 50 58 65 70 63 55 48 2,500 3,000 53 60 68 Thesefansarealsobuilttotakecareofthehomeownersspotventilationneeds whentheroomisoccupied.Thesemodelskick-uptoamaximumlevelof80 CFMeitherwhentheswitchisturnedon(FV-08VKSL2)oractivatedbythe AHigh/LowDelayTimer,Iocatedinsidethefanbody,isutilizedtoreturnthefan backtothePre-setcontinuousventilationmode .factorsincreasestaticpressurehinderingtheperformanceofmostventilation fans.Thesefansutilizemicrochiptechnologythatmonitorsthe staticpressureinthesystemandspeedsuporslowsdowntherpmofthefan dependingontheamountofresistance.Thisallowsthefantoperformasrated, whetherfacing0.1,0.2oreven0.25incheswatergauge.Thebottomlineisthat itmakesforeasierinstallation.Theinstallernolongerhastoworryabout compromisingthefansperformance. technology.ThenewDCmotoris30%-70%moreenergyefficientthantheminimum ENERGYSTARrequirements. Thisproductcontainselectronicballastwithfluorescentlampsandisincompliance withPart18oftheFCCrulesasconsumerRFlightingdevice.Operationissubjectto thefollowingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and (2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmay causeundesiredoperation. Thisproductmaycauseinterferencetoradioequipmentandshouldnotbeinstalled nearmaritimesafetycommunicationsequipmentorothercriticalnavigationor communicationequipmentoperatingbetween0.45-30MHz.Ifinterference shouldoccur,trytoincreasespacingbetweenthisproductandotherproduct. DocResponsibleParty:PanasonicCorporationofNorthAmerican OnePanasonicWay,Secaucus,NJ07094 PanasonicHome&EnvironmentCompany UnitofPanasonicConsumerElectronicCompany OnePanasonicWay,Secaucus,NJ07094 1-866-292-7292 SalesCompany: CustomerCallSupport: 2TMSpotandContinuousVentilation: 75 PDF created with pdfFactory Pro trial version www.pdffactory.com
UNPACKING Unpackandcarefullyremoveunitfromcarton. RefertotheSuppliedAccessorieslisttoverifythatallpartsarepresent. SUPPLIEDACCESSORIES Partname Appearance Quantity Grille FV-08VKML2 FV-08VKSL2 Suspension bracket I Suspension bracket II Suspension bracket III Screw (ST4.2X8) I Screw (ST4.2X12) II Screw (ST4.2X16) III Partname Appearance Quantity Machinescrew (M4X8) Longscrew (ST4.2X20) 18W Fluorescent lamp 4W Nightlamp Lightingunit DESCRIPTION ThesePanasonicventilatingfanmodelsuseasiroccofanwithdolphin-shapedbladesdrivenbybrushlessdirect currentmotorpoweredbyanintegraltransformer.Themotorisdesignedtohavelongoperatinglife,high dynamicresponse.higherspeedrangeswithsavingenergy.Thegrillecoveringthefanbodyisaspring-loaded, quickremovetype.Adamperforpreventingaircounterflowisprovided.Theblowerusesahigh-capacity siroccofandevelopedtoreducethenoiselevel. Thelightingunitisanenergy-saving,lightingdeviceusestwo18Wfluorescentlampsandproducesalmost thesameilluminationasastandard100Wincandescentlamp. PanasonicventilatingfanmodelFV-08VKML2isequippedwithamotionsensorthatshiftsthefantohigh flowautomaticallywhenmotionisdeteced.Itisuse-adjustabletooperate0.5-60minutesaftermotionisno longerdetected. 3 PDF created with pdfFactory Pro trial version www.pdffactory.com
DIMENSIONS FV-08VKML2 Unit:inches(mm) FV-08VKSL2 No.Partname No. Partname Grille Junctionboxcover Junctionbox Lightingunit Fluorescentlamp Nightlamp Sensorunit Adatpor Fanbody Damper Suspensionbracket Bracketcover (For16inchesoncenterjoists,onlyusesuspensionbrasket,for19.2inchesoncenterjoists,onlyuse suspensionbracket.Ifmorethan19.2inchesoncenterjoists,usesuspensionbrasket&.) IIIIIIII 1 2 3 4 5 6 7 8 9 10 11 12 101/4(261) 13(330) 10 8 3 6 23/4(70)312(90) 1(25) 1(26) 43/5(116) 23/4(70) 312(90) 1(26) I 4 PDF created with pdfFactory Pro trial version www.pdffactory.com
FV-08VKML2 WIRINGDIAGRAM Fanbody Junctionbox Switchbox L N AC120V60Hz Black White Green Black Red Adjustmentswitch Maincontrolcircuit Black White Red Blue Orange Purple DC-Motor Sensor Red White Yellow Black Red White Yellow Black WhiteBlackBlack Black Black Switchbox L L Nightlamp Green Electronic Ballast Lamp Lightingunit FV-08VKSL2 Fanbody Junctionbox Switchbox L N White Red Black Red Green G Black White Red Red Adjustmentswitch Black White Red Blue Orange Purple DC-Motor Maincontrolcircuit Red White Yellow Lightingunit Black Black White Green Nightlamp L L Switchbox Black Black Lamp Electronic ballast SWITCHINDICATION Lowspeedairvolumepresetswitch High/lowdelaytime presetswitch Switchindications onblowerunit Lowspeedair-volumepresetswitchpositions AirVolume[CFM] 0 30 40 50 60 70 Factorysetting:50CFM.Position:Useforfactorytestonly. PositionFanstop : High/Lowdelaytimepresetswitchpositions DelayTime[min] 0.5 1 2 3 510 20 30 60 Factorysetting:20minutes.Position:Useforfactorytestonly. AirvolumepresetswitchDelaytimepresetswitch White AirvolumepresetswitchDelaytimepresetswitch 5 Powersupply AC120V60Hz AC120V60Hz Powersupply AC120V60Hz Powersupply Powersupply PDF created with pdfFactory Pro trial version www.pdffactory.com
OPERATION Detectiblerange Thedistancethatmotion canbedetectedlimitedto 10feet(3m). Thefieldofviewofthe sensoris90. (Roomtemperatureis 25C)Motionsensor Thelowspeedisdeterminedlowspeedairvolumepresetswitch. by ThedelaytimeisdeterminedbyHigh/Lowdelaytimepresetswitch. Fanoperatesathighspeedforadjustabledurationof0.5to60min.aftermotionisnolongerdetected. Atlow speed Whenmotionis detected,fanruns atthehighspeed. Remainsrunning athighspeeduntil thedelaytimehas passed. Human active Human active Fanactive Fanactive Atlow speedWhenmanualwall switchisclosed, fanrunsathigh speed. Whenmanulewall switchisopened, fanremainsrunning athighspeeduntil thedelaytimehas passed. SPECIFICATIONS Specifications ModelNo. Air direction Voltage (V) Frequency (Hz) Duct diameter (inches) Noise (sones) Fanbody Powerconsumption(W) Speed (rpm) Lightingunit FluorescentlampNightlamp Airdeliverat0.1WG (CFM) Weight Ib.() FV-08VKSL2 Exhaust Exhaust 120 60 4 120 60 4 FV-08VKML2 9.6 7.8 6.8 5.9 5.0 1.4() 9.6 7.8 6.8 5.9 5.0 18X2 18X2 18X2 18X2 18X2 18X2 18X2 18X2 18X2 18X2 18X2 18X2 4 4 4 4 4 4 4 4 4 4 4 4723 675 661 625 587 723 675 661 625 587 70 60 50 40 30 0 70 60 50 40 30 16.3(7.4) FV-08VKSL2 FV-08VKML2 Exhaust Exhaust 120 60 60 120 4 40.3 0.3 12.6 12.6 18X2 18X2 4 4 807 807 80 8016.5(7.5) 16.3(7.4) HVICertifiedperformancebasedonHVIProcedures915,916,and920 Referencespecifications ModelNo. Air direction ReferenceperformancebasedonHVIProcedures915,916,and920. Duct diameter (inches) Powerconsumption(W) Noise (sones) SpeedWeight (rpm) (CFM) 16.5(7.5) Airdeliverat0.1WG Fanbody FluorescentlampNightlampLightingunit 6 kg Ib.() kg 0 * 1.4() * ()Standbywattage. * Voltage (V) Frequency (Hz) PDF created with pdfFactory Pro trial version www.pdffactory.com
GENERALSAFETYINFORMATION 1.Donotinstallthisventilatingfanwhereinteriorroomtemperaturemayexceed 104F(40C). 2.MakesurethattheelectricservicesupplyvoltageisAC120V,60Hz. 3.Followalllocalelectricalandsafetycodes,aswellastheNationalElectricalCode (NEC)andtheOccupationSafetyandHealthAct(OSHA). 4.Alwaysdisconnectthepowersourcebeforeworkingonornearthefan,motor, lightfixtureorjunctionbox. 5.Protectthepowercordfromsharpedges,oil,grease,hotsurfaces,chemicalsor otherobjects. 6.Donotkinkthepowercord. 7.DonotinstalltheunitwhereductsareconfiguredasshowninFig.A. 8.Providesuctionpartswithproperventilation. 9.ThisunitisULlistedforuseoverabathtuborshowerwheninstalledinaGFCI protectedbranchcircuit. 10.Thisproducthasafluorescentlampthatcontainsmercury.Disposalmayberegulated inyourcommunityduetoenvironmentalconsiderations.Fordisposalorrecycling information,pleasecontactyourlocalauthoritiesortheElectronicslndustries Alliance: http://www.eiae.org CAUTION: 1.Forgeneralventilatinguseonly.Donotusetoexhaust hazardousorexplosivematerialsandvapors. 2.Notforuseincookingarea.(Fig.B) 3.Thisproductmustbeproperlygrounded. WARNING: Toreducetheriskoffire,electricshockorinjurytopersons,observethefollowing: 1.Usethisunitonlyinthemannerintendedbythemanufacturer.ifyouhaveanyquestions,contactto themanufacturer. 2.Installationworkandelectricalwiringmustbedonebyqualifiedperson(s)inaccordancewithall applicablecodesandstandards,includingfire-ratedconstruction. 3.Sufficientairisneededforpropercombustionandexhaustiongofgasesthroughtheflue(chimeny) offuelburningequipmenttopreventbackdrafting.Followtheheatingequipmentmanufacturers guidelineandsafetystandardssuchasthosepublishedbytheNationalFireProtectionAssociation (NFPA),andtheAmericanSocietyforHeatingRefrigerationandAirConditioningEngineers (ASHRAE)andthelocalcodeauthorities. 4.Whencuttingordrillingintowallorceiling,donotdamageelectricalwiringandotherhiddenutilities. 5.Ductedfansmustalwaysbeventedtotheoutdoors. 6.Donotusethisunitwithanysolid-statecontroldevice.Solidstatecontrolsmaycauseharmonicdistortion whichcancausemotorhummingnoise. 7.Beforeservicingorcleaningunit,switchpoweroffatservicepanelandlocktheservicedisconnecting meanstopreventpowerfrombeingswitchedonaccidentally,Whentheservicedisconnectingmeans cannotbelocked,securelyfastenaprominentwarningdevice,suchasatag,totheservicepanel. 8.Ifthisunittobeinstalledoveratuborshower,itmustbemarkedasappropriatefortheapplication andbeconnectedtoaGFCI(GroundFaultCircuitInterrupter)-protectedbranchcircuit. 9.NottobeinstalledinaceilingthermallyinsulatedtoavaluegreaterthanR40.(Thisisrequiredfor installationinCanadaonly.) (Cookingarea) Donotinstallaboveor insidethisarea Cooking equipment Floor Fig.B Fig.A Prohibited Prohibited Adaptor Prohibited Prohibited 7 PDF created with pdfFactory Pro trial version www.pdffactory.com
INSTALLATION(JOISTMOUNTING-) IMPORTANT: Adaptor Damper Tape Joists 2-Screw(ST4.2X8) I Suspensionbracket II Suspensionbracket III SpacingAoncenterjoists 12inches InsertSuspensionbracket RefertoFig.1-1 RefertoFig.1-2 RefertoFig.1-3 RefertoFig.1-4 16inches 19.2inchesverticaljoists 24inches Removethetapefromdamperandadaptor beforeinstallation.Asshownbelow: IfspacingAoncenterjoistsis24inches,connect suspensionbracketand(C4marktoC4mark) asshownbelow: IIIII 1.Insertthesuspensionbracketintothefanbodyand adaptor.(Selectthesuspensionbracketasshownbelow.) Fanbody Fanbody Fanbody Fanbody Suspension bracket I Suspension bracket III Suspension bracket III Suspension bracket III Suspension bracket II Suspension bracket I Suspension bracketI Suspension bracket I Fig.1-1 Fig.1-2 Fig.1-3 Fig.1-4 8 PDF created with pdfFactory Pro trial version www.pdffactory.com
INSTALLATION(JOISTMOUNTING-)CONTINUED 2.Installthesuspensionbracketandtheflangeof fanbodytojoistsbyusinglongscrews(ST4.2X20) (IfspacingAbetweenjoistsis12inches,installthe flangeoffanbodyaccordingtoFig.2-1,others accordingtoFig.2-2toinstalltheproduct) 3.Installthesuspensionbrackettojoistsbyusing longscrews(ST4.2X20)andsecureittothefan bodybyusingscrew(ST4.2X12)(Fig.3) II 4.Removejunctionboxcoverandsecureconduit orstressrelieftojunctionboxknock-outhole. (Fig.4) 6.Installacircularductandsecureitwith ducttapeorclamps. 5.Refertowiringdiagramofpage5. Followallthelocalelectricalsafetycodesas wellastheNationalElectricalCode(NEC). UsingULapprovedwirenuts,connecthouse powerwirestoventilatingfanwires: blacktoblack;whitetowhite;greentogreen; FormodelFV-08VKSL2connectthetwo redwirestotheswitchforthespeedcontrol. Replacethejunctionboxcover.(Fig.4) Mountjunctionboxcovercarefullysothat leadwiresarenotpinched. CAUTION: Joist Joist Joist Ducttape orclamps Circularduct Conduit (FV-08VKML2) (FV-08VKSL2) Junctionboxcover Fig.2-1 Fig.2-2 Fig.3 Fig.4 Fanbody Fanbody 2Longscrews (ST4.2X20) 2Longscrews (ST4.2X20) Screws(ST4.2X12)II 4Longscrews(ST4.2X20) Joist 9 Conduit Redwires Greenwires Leadwires Wirenut Junctionbox Greenwires Leadwires Wirenut Junctionbox Conduit PDF created with pdfFactory Pro trial version www.pdffactory.com
7.Finishceilingwork.Ceilingholeshouldbealigned withtheedgeoftheflange.(Fig.5) 8.Inserttheplugconnectorintothereceptacle, andsecurethelightingunittothefan bodywith1screw(ST4.2X16)and2machine screws(M4X8).(Fig.5) IIII III 9.Insertthefluorescentlampsandsecurethenight lampintothelightingunit.(Fig.5) 10.Insertmountingspringintotheslotasshownand adjusthigh/lowdelaytimepresetswitchandlow speedairvolumepresetswitch.Refertoswitch indicationonpage5(FV-08VKML2)(Fig.6-1) 11.Insertthesensorunitintothehousingofthegrille andinsertothermountingspringintotheslotas shownandmountgrilletofanbody(FV-08VKML2) (Fig.6-2,Fig.6-3) 12.Insertmountingspringsintotheslotsasshownand mountgrilletofanbody.(FV-08VKSL2)(Fig.7) Mountgrillecarefullysothatleadwireofsensorunit isnotpinched. CAUTION: INSTALLATION(JOISTMOUNTING-)CONTINUED Ceiling Lightingunit Machinescrew (M4X8) Machinescrew (M4X8) Screw(ST4.2X16) III 4WNightlamp Fluorescentlamps Inches(mm) Plugconnector II Mountingspring Mountingspring Ceiling Ceiling Ceiling Ceiling Grille Grille Grille Gloves Grille Slot LightingunitLightingunit Sensorunit SensorunitFig.5 Fig.6-1 Fig.6-2 Fig.6-3 Fig.7 Gloves 10Receptacle II Plugconnector II Gloves GlovesThemachinescrewsmustbetightfit. CAUTION: PDF created with pdfFactory Pro trial version www.pdffactory.com