Page 1

VentilatingFan
INSTALLATIONINSTRUCTIONS
ModelNo. FV-08VKML2
FV-08VKSL2
FV-08VKML2 FV-08VKSL2
READANDSAVETHESEINSTRUCTIONS.
ThankyouverymuchforhavingpurchasedourVentilatingFan
Pleasereadtheseinstructionscarefullybeforeattemptingtoinstall,
operateorservicethePanasonicVentilatingFan.Failuretocomply
withinstructionscouldresultinpersonalinjuryand/orproperty
damage.Pleaseretainthisbookletforfuturereference.
TableofContents
PleaseReadPriorToInstallingThisFan
Unpacking
SuppliedAccessories
Description
Dimensions...

Page 2

PLEASEREADPRIORTOINSTALLINGTHISFAN
TheWhisperGreenlineofventilatingfansemploysstateofthearttechnology
providinganumberofuniquefeaturesthatleadtoimprovedindoorairquality.
Thesefeaturesneedtobefullyunderstoodpriortoinstallationtofullyrealizethe
benefitsthefansoffer. Thesefansaredesignedtoruncontinuously
ensuringahealthyenvironmentatlowCFMlevels24hoursaday.Byutilizing apre-setlowerlevel(0,30,40,50,60,70CFM).Thesettingisdependentonthe
sizeoftheroomandtheindividualwishesofthehomeowner.
(Sq.feet)...

Page 3

UNPACKING
Unpackandcarefullyremoveunitfromcarton.
RefertotheSuppliedAccessorieslisttoverifythatallpartsarepresent.
SUPPLIEDACCESSORIES
Partname Appearance Quantity
Grille FV-08VKML2
FV-08VKSL2
Suspension
bracket I
Suspension
bracket II
Suspension
bracket III
Screw
(ST4.2X8) I
Screw
(ST4.2X12) II
Screw
(ST4.2X16) III Partname
Appearance Quantity
Machinescrew (M4X8)
Longscrew
(ST4.2X20)
18W
Fluorescent lamp
4W
Nightlamp
Lightingunit
DESCRIPTION...

Page 4

DIMENSIONS
FV-08VKML2 Unit:inches(mm)
FV-08VKSL2
No.Partname No.
Partname
Grille Junctionboxcover
Junctionbox
Lightingunit
Fluorescentlamp
Nightlamp
Sensorunit
Adatpor
Fanbody
Damper
Suspensionbracket
Bracketcover
(For16inchesoncenterjoists,onlyusesuspensionbrasket,for19.2inchesoncenterjoists,onlyuse suspensionbracket.Ifmorethan19.2inchesoncenterjoists,usesuspensionbrasket&.) IIIIIIII
1
2
3
4
5
6
7
8
9
10
11
12
101/4(261)
13(330)
10
8
3
6 23/4(70)312(90) 1(25)
1(26) 43/5(116) 23/4(70)
312(90) 1(26)
I
4...

Page 5

FV-08VKML2
WIRINGDIAGRAM
Fanbody Junctionbox
Switchbox
L
N AC120V60Hz
Black
White
Green
Black Red
Adjustmentswitch
Maincontrolcircuit
Black White
Red
Blue
Orange
Purple
DC-Motor
Sensor Red
White Yellow
Black Red
White Yellow
Black
WhiteBlackBlack Black
Black Switchbox
L
L
Nightlamp
Green
Electronic
Ballast
Lamp Lightingunit
FV-08VKSL2 Fanbody
Junctionbox
Switchbox
L
N
White
Red Black
Red Green G Black
White Red
Red
Adjustmentswitch
Black
White
Red
Blue
Orange
Purple
DC-Motor Maincontrolcircuit
Red
White...

Page 6

OPERATION
Detectiblerange Thedistancethatmotion
canbedetectedlimitedto
10feet(3m).
Thefieldofviewofthe
sensoris90.
(Roomtemperatureis
25C)Motionsensor
Thelowspeedisdeterminedlowspeedairvolumepresetswitch. by
ThedelaytimeisdeterminedbyHigh/Lowdelaytimepresetswitch. Fanoperatesathighspeedforadjustabledurationof0.5to60min.aftermotionisnolongerdetected.
Atlow
speed
Whenmotionis
detected,fanruns
atthehighspeed. Remainsrunning
athighspeeduntil
thedelaytimehas
passed. Human
active
Human
active
Fanactive...

Page 7

GENERALSAFETYINFORMATION
1.Donotinstallthisventilatingfanwhereinteriorroomtemperaturemayexceed
104F(40C).
2.MakesurethattheelectricservicesupplyvoltageisAC120V,60Hz.
3.Followalllocalelectricalandsafetycodes,aswellastheNationalElectricalCode (NEC)andtheOccupationSafetyandHealthAct(OSHA).
4.Alwaysdisconnectthepowersourcebeforeworkingonornearthefan,motor, lightfixtureorjunctionbox.
5.Protectthepowercordfromsharpedges,oil,grease,hotsurfaces,chemicalsor otherobjects.
6.Donotkinkthepowercord....

Page 8

INSTALLATION(JOISTMOUNTING-)
IMPORTANT:
Adaptor Damper
Tape
Joists
2-Screw(ST4.2X8) I
Suspensionbracket II
Suspensionbracket III
SpacingAoncenterjoists
12inches InsertSuspensionbracket
RefertoFig.1-1
RefertoFig.1-2
RefertoFig.1-3
RefertoFig.1-4
16inches
19.2inchesverticaljoists
24inches Removethetapefromdamperandadaptor
beforeinstallation.Asshownbelow:
IfspacingAoncenterjoistsis24inches,connect
suspensionbracketand(C4marktoC4mark)
asshownbelow:
IIIII
1.Insertthesuspensionbracketintothefanbodyand...

Page 9

INSTALLATION(JOISTMOUNTING-)CONTINUED
2.Installthesuspensionbracketandtheflangeof
fanbodytojoistsbyusinglongscrews(ST4.2X20)
(IfspacingAbetweenjoistsis12inches,installthe
flangeoffanbodyaccordingtoFig.2-1,others
accordingtoFig.2-2toinstalltheproduct)
3.Installthesuspensionbrackettojoistsbyusing longscrews(ST4.2X20)andsecureittothefan
bodybyusingscrew(ST4.2X12)(Fig.3) II
4.Removejunctionboxcoverandsecureconduit orstressrelieftojunctionboxknock-outhole.
(Fig.4)
6.Installacircularductandsecureitwith...

Page 10

7.Finishceilingwork.Ceilingholeshouldbealigned
withtheedgeoftheflange.(Fig.5)
8.Inserttheplugconnectorintothereceptacle, andsecurethelightingunittothefan
bodywith1screw(ST4.2X16)and2machine
screws(M4X8).(Fig.5) IIII
III
9.Insertthefluorescentlampsandsecurethenight lampintothelightingunit.(Fig.5)
10.Insertmountingspringintotheslotasshownand adjusthigh/lowdelaytimepresetswitchandlow
speedairvolumepresetswitch.Refertoswitch
indicationonpage5(FV-08VKML2)(Fig.6-1)...