Panasonic Ventilating Fan Fv 05vfl3 Installation Instructions

Here you can view all the pages of manual Panasonic Ventilating Fan Fv 05vfl3 Installation Instructions. The Panasonic manuals for Ventilation are available online for free. You can easily download all the documents as PDF.

Page 11

2 Screw
(ST4.2X12)
INSTALLATION     (WOODEN HEADER ) INSTALLATION     (BETWEEN JOIST MOUNTING ) CONTINUED3. Insert the fan body between joists.
    Make sure the fan body is level and square
    (perpendicular) with the joists. (Fig.17)
    Ensure that distance B (7/8 inch, 21.6mm) for the
    thickness of ceiling board.
5. Secure the suspension bracket to fan body by using
    screws    (ST4.2X12). (Fig.19) 4. Secure the suspension bracket to joists by using long
    screws (ST4.2X20). (Fig.18, Fig.19)...

Page 12

INSTALLATION     (IN EXISTING CONSTRUCTION )  INSTALLATION    (WOODEN HEADER ) CONTINUED4. Follow step 5 to 11 of installation   (page 7
~page 8)
    to complete the installation work.
1. Installation in existing construction.
    Installing the fan body in an existing building requires an accessible area (attic or crawl space) above
    the planning installation location or existing ducting and wiring.
(1) To install the fan body, follow the procedures described in lnstallation   . Take the following...

Page 13

WARNING:
CAUTION: Disconnect power source before working on unit. 
Routine maintenance must be done every year. 1. Never use petrol, benzene, thinner or any other such
    chemicals for cleaning the ventilating fan.
2. Do not damp water to enter motor.
3. Do not soak resin parts in water over 140  F(60  C).
1. Remove grille. (Squeeze mounting spring and pull down
    carefully.) (Fig.22)
2. Wash and clean grille. (Use non-abrasive kitchen detergent,
    wipe dry with new cloth.) (Fig.23)
4. Using a cloth...

Page 14

Receptacle ReceptaclePlug connectorPlug connector
4 inches or 6 inches roof jack, wall cap,
or soffit vent with backdraft damper
Mechanically connect duct to termination
and seal with mastic or approved foil
faced tape
2-3 ft straight run before elbow In attic installation,
caulk box to drywall
Short piece of flexible duct helps
alignment and absorbs sound.
Clamps plus mastic or approved
foil faced tape at all flex joints Foil tape tightly covers all metal
duct joints (glue PVC joints)
Insulation
Fig. 28...

Page 15

PRODUCT SERVICE
Warning Concerning Removal of Covers.
The unit should be serviced by qualified technicians only.
Your product is designed and manufactured to ensure a minimum of mainten\
ance.
Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7292 (USA)
or 1-800-669-5165 (Canada).  32
FV-08VFL3
SPECIFICATIONS
Model      Air 
direction    Voltage
        (V)
    Frequency
         (Hz)   Duct
diameter
 (inches) Noise
(sones)  Power consumption (W)
 Fluorescent lamp...

Page 16

T0212-0   08VFL3420Panasonic Corporation of North America
One Panasonic Way, Secaucus, New Jersey 07094
www.panasonic.com
Panasonic Canada lnc.
5770 Ambler Drive, Mississauga, Ontario L4W 2T3
www.panasonic.ca
Printed in China Panasonic corporation 2012 
Start reading Panasonic Ventilating Fan Fv 05vfl3 Installation Instructions

Related Manuals for Panasonic Ventilating Fan Fv 05vfl3 Installation Instructions

All Panasonic manuals