    Have a look at the manual Panasonic Ventilating Fan Fv 05vfl3 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							FV-05VFL3  
    FV-08VFL3
    FV-11VFL3INSTALLATION  INSTRUCTIONS
      
    Ventilating Fan Contents
    Description
    Dimensions General Safety lnformation
    Unpacking
    Wiring Diagram
    lnstallation    (Joist Mounting-  )
    lnstallation    (Joist Mounting-   )
    lnstallation    (   -Joist Mounting)
    lnstallation     (Between Joist Mounting )
    lnstallation    (Wooden Header )
    lnstallation     (ln Existing Construction )
    Maintenance   (Cleaning)
    Maintenance     (Replacement of Lamp)
    Practical Guide to lnstallation
    Product Service2-3
    4 4
    4
    5 5
    6-8
    8-9
    10
    10-11
    11-12 12
    13
    13-14
    14
    15 15
    Supplied Accessories
    SpecificationsModel No.
    READ AND SAVE THESE INSTRUCTIONS Thank you very much for having purchased our product.
    Please read these instructions carefully before attempting to install, operate or service 
    the Panasonic product. Failure to comply with instructions could result in personal injury 
    or property damage. Please explain to users how to operate and maintain the product 
    after installation, and this booklet should be presented to users.
    Please retain this booklet for future reference. 
    						
    							GENERAL SAFETY INFORMATION 
    2To reduce the risk of fire, electric shock or injury to persons, observe\
     the following:
    9. Do not use this fan with any solid-state speed control device. 2. Before servicing or cleaning unit, switch power off at service panel \
    and lock the service 
        disconnecting means to prevent power from being switched on accident\
    ally. When the service 
        disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, 
        to the service panel. 
    7. If this unit is to be installed over a tub or shower, it must be mark\
    ed as appropriate for the 
        application and be connected to a GFCI (Ground Fault Circuit lnterr\
    upter) - protected branch circuit. 
    10. Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40.
    15. Do not install the product as the method which is not approved in th\
    e instruction.  11. Do not disassemble the unit for reconstruction. lt may cause fire or electric shock.
    12. A statement to the effect that when the product is to no longer be u\
    sed, it must not be left in 
          place but removed, to prevent it from possibly falling.  14 . The special-purpose or dedicated parts, such as mounting fixtures, must be used if such parts are 
          provided.  3. Installation work and electrical wiring must be done by qualified per\
    son (s) in accordance with all
        applicable codes and standards, including fire-rated construction. 
    5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
    6. Ducted fans must always be vented to the outdoors. 
    8. These models are UL listed for tub and shower enclosures. 4. Sufficient air is needed for proper combustion and exhausting of gase\
    s through the flue (chimney)
        of fuel burning equipment to prevent back drafting. Follow the heati\
    ng equipment manufacturer s
        guideline and safety standards such as those published by the Nation\
    al Fire Protection Association
        (NFPA), and the American Society for Heating, Refrigeration and Ai\
    r Conditioning Engineers
        (ASHRAE) and the local code authorities.  
    WARNING:
    1. Use this unit only in the manner intended by the manufacturer. lf you\
     have any questions, contact
        the manufacturer.
    13. Ceiling joist must be subjected to static load more than five times \
    the weight of the product. 
    16. This product must be properly grounded. 
    						
    							GENERAL SAFETY INFORMATION CONTINUED
    3
    11. USA only: This product has a fluorescent lamp that contains mercury. Disposal may be regulated in 
           your community  due to environmental considerations. For disposal\
     or recycling information, please 
           contact your local authorities or visit Panasonic website: http:/\
    /www.panasonic.com/enveronmental 
           or call 1-888-769-0149. 1. Do not install this ventilating fan where interior room temperature m\
    ay exceed 104  F (40  C).
    2. Make sure that the electric service supply voltage is AC 120V, 60 Hz.
    3. Follow all local electrical and safety codes, as well as the National\
     Electrical Code (NEC) and the
        Occupation Safety and Health Act (OSHA).
    4. Always disconnect the power source before working on or near the fan, motor, light fixture or 
        junction box.
    5. Protect the supply wiring from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
    6. Do not kink the supply wiring.
    7. Provide make up air for proper ventilation.
    8. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
    10. Not for use in cooking area. (Fig. B) CAUTION: Prohibition
    Prohibition Prohibition ProhibitionAdaptor
    Fig. A      (Cooking area)
    Do not  install above or 
          inside this  area
          Cooking
        equipment       Floor
    4
    545
    Fig. B
    9. Do not install the unit where ducts are configured as shown in Fig. A. 
    						
    							FV-05VFL3     FV-08VFL3     FV-11VFL3SUPPLIED ACCESSORIES
    Part name Part name
    Appearance Appearance
    Quantity Quantity
    Grille
     Suspension
       bracket    Suspension
       bracket  
     Suspension
      bracket  
      Screw
    (ST4.2X8) 
      Screw
    (ST4.2X12)  1
    1
    1
    1
    2
    2
      Machine screw
            (M4X8) 
            Long screw
            (ST4.2X20) 
            32W
      Fluorescent
            lamp
            4W
     Night lamp
            Lighting unit 2
    6
    1
    1
    1UNPACKING
    Unpack and carefully remove unit from carton.
    Refer to the Supplied Accessories list to verify that all parts are present. DESCRIPTION
    1
      Screw
    (ST4.2X16) 
    2         3 inches adaptor
                 connector
             (optional part)
    4 These products are listed by UL under UL file No. E78414.
    These products use a sirocco fan driven by a capacitor motor. The motor is designed to have an extended 
    service life with reduced energy consumption. lt also incorporates a the\
    rmal-cutoff for safety. 
    The grille covering the main body is a spring-loaded, quick-release type\
    . 
    A damper for preventing counterflow is provided.
    The lighting unit is an energy-saving lighting device which uses one 32W\
     fluorescent lamp and produces 
    almost the same illumination as a standard 100W incandescent lamp.
    This product contains electronic ballast with one fluorescent lamp and is in compliance with Part 18 of 
    the FCC rules as consumer RF lighting device. Operation is subject to th\
    e following two conditions: 
    (1) This device may not cause harmful interference. 
    (2) this device must accept any interference received, including inter\
    ference that may cause undesired 
          operation.
    This product may cause interference to radio equipment and should not be\
     installed near maritime safety 
    communications equipment or other critical navigation or communication e\
    quipment operating between 
    0.45-30 MHz. lf interference should occur, try to increase spacing betwe\
    en this product and the other 
    product.
        
    Doc Responsible Party:            Panasonic Corporation of North America\
                                                       One Panasonic Way, Se\
    caucus, NJ 07094
    Sales Company:                        Panasonic Corporation of North Ame\
    rica
                                                       One Panasonic Way, Se\
    caucus, NJ 07094
    Customer Call Support:           1-866-292-7292 
    						
    							FV-05VFL3
    FV-08VFL3
    FV-11VFL3 WIRING DIAGRAM
    No. Part name
    GrilleFan
    Lighting unit
    Junction box cover Adaptor
    Fluorescent lamp DamperSuspension bracket Junction box Bracket cover
    Night lamp 8
    9
    10
    11
    13
    1
    2
    3
    4 5
    6
    (For 16 inches on center joists, only use suspension bracket   , for 19.2 inches on center joists, only use 
    suspension bracket     , lf more than 19.2 inches on center joists, use suspension bracket             ) FV-05VFL3
    FV-08VFL3
    FV-11VFL32  7/8 (73)1   (25) 1  3/4 (45)
    1 (26)3  1/ 2 (90)11
    12
    3
    13
    4  3/8 (110)
    5  1/ 2 (141)
    3  1/4 (81)
    13  1/4~15  1/2 (336~ 394)
    16  1/2~ 18  3/4 (419~ 480)
    21  1/4~ 23  1/2 (540~ 597) 
    Unit: inches(mm)
    Fan body
    Adaptor connector
    7 No.
    Part name
    12
    DIMENSIONS
    1
    5
    6 4
    2
    7
    13  (330)
    3  7/8 (98)
    2  15/16 (74)
    11  7/8 (301) 10  1/4 (259)
    10
    9
    8
    10  1/4 (261) 16  1/8 (410)
    5 
    						
    							lf spacing A on center joists is 24 inches, connect
    suspension bracket 
       and    (C4 mark to C4 mark)
    as shown below:
    2 Screw   (ST4.2X8) Suspension bracket
    Suspension bracket2. lnsert the suspension bracket into the fan body 
        and adaptor. (Select the suspension bracket as 
        shown below) Joists
    Spacing A on center joists
    24 inches  12 inches
    16 inches
    19.2 inches vertical joists lnsert Suspension bracket
    Refer to Fig. 2-1
    Refer to Fig. 2-2
    Refer to Fig. 2-3
    Refer to Fig. 2-4 INSTALLATION   (JOIST MOUNTING-  )
    1. Before installation, secure the fan body to adaptor 
         by using machine screw (M4X8). (Fig. 1) 
    IMPORTANT:
    Remove the tape from damper and adaptor 
    before installation. As shown below:  
    Tape
    Damper Adaptor
    Fig. 2-4
    Fan body
    Fig. 2-1
    Fan body Suspension 
    bracket
    Fig. 2-2Fig. 2-3
    Machine screw
        (M4X8)
    Fig. 1 Suspension 
    bracket
    Fan body Suspension 
    bracket
    Suspension 
    bracket
    Suspension 
    bracket
    Fan body Suspension 
    bracket
    Suspension 
    bracket
    Fan body Suspension 
    bracket
    6 Connection method for 3 inches adaptor connector 
    						
    							INSTALLATION   (JOIST MOUNTING-  ) CONTINUED3. Install the suspension bracket and the flange of fan 
        body to joists by using long screws(ST4.2X20). (If 
        spacing A between joists is 10 1/4~12 inches, install 
        the flange of fan body according to Fig. 3-2, others 
        according to Fig. 3-1 install the product.)
    4. Install the suspension bracket to joists by using long
        screws (ST4.2X20) and secure it to the fan body by
        using screw    (ST4.2X12). (Fig.4)
    5. Remove junction box cover and secure conduit or 
        stress relief to junction box knock-out hole. (Fig.5)
    6. Refer to wiring diagram (page 5).
        Using wire nuts, connect house power wires to
        ventilating fan wires:
        black to black; white to white; green to green;
        Replace the junction box cover. (Fig.5)
    CAUTION:
    Mount junction box cover carefully so that lead
    wires are not pinched.
    7. lnstall a circular duct (using 4 inches duct or 3 inches
        duct) and secure it with duct tape or clamps.
    2 Long screws
    (ST4.2X20)
    A=10 1/4
    ~12 inches
    Junction box
    Joist
    Joist
    Fan body
    4 Long screws (ST4.2X20) Fig. 3-1
    Fig. 3-2 Fig. 4
    Joist
    Joist
    Fan body 2 Long screws
    (ST4.2X20)
    Screw
    (ST4.2X12) Joist
    Joist
    Knock-out hole Circular duct
    Conduit Joist
    Joist Conduit
    Junction box
    cover
    Duct tape
    or clamps
    Wire nut
    Lead wires Green wires Fig. 5
    7 
    						
    							13 1/4~
    15 1/ 2(336 ~394)
    16 1/  2~ 18 3/  4(419 ~480)
    21 1/  4~ 23 1/  2(540 ~597)
    A INSTALLATION   (JOIST MOUNTING-  ) CONTINUED8. Finish ceiling work. Ceiling hole should be aligned
        with the edge of the flange. (Fig.6)
    9. Insert the plug connector    and plug connector
        into the receptacle    and receptacle     respectively,
        and secure the lighting unit to the fan unit with 2
        screw     (ST4.2X16) and 1 machine screw (M4X8).
        (Fig.6)
    10. Insert the fluorescent lamp and screw the night
          lamp into the lighting unit. (Fig.6)
    11. Insert mounting springs into slots as shown
          and mount grille to fan body. (Fig.7) INSTALLATION    (JOIST MOUNTING-   ) 
    2. Insert the suspension bracket into the adaptor and
        secure it to joists by using long screws (ST4.2X20).
        (Fig.8)
        Ensure that distance B (7/8 inch, 21.6mm) for the
        thickness of ceiling board. 1. Disconnect plug connector from receptacle and
        remove adaptor from fan body before starting
        installation. 
    3. Follow step 5 to 7 of the installation   (page 7) to
        complete the duct work and wiring.
    If spacing A between joists is 21 1/4 to 23 1/  2
    inches, (540mm ~597mm), connect suspension 
    bracket    and     (C4 mark to C4 mark) according 
    to page 6. Select the suspension bracket according 
    to spacing A as shown below.
    Spacing A
    between Joists
    inches (mm)
    suspension
    bracket suspension
    bracket
    suspension
    bracketsuspension
    bracket     &
    21 1/  4~ 23 1/  2
       (540 ~597)
    13 1/4
    ~15 1/  2
       (336 ~394) 16 1/
     2~ 18 3/  4
       (419 ~480)
    Ceiling Plug connector Plug connector
    Plug connector Plug connector
    Receptacle Receptacle
    Mounting spring
    Lighting unit
    Slot
    Ceiling
    Grille
    )
    10 7 /8 (27510 7/ 275
    8  ( )
    Lighting unit
    Screw
    (ST4.2X16)
    Machine screw
    (M4X8)
    Fluorescent lamp
    Unit: inches (mm) 4 W Night Lamp
    Fig. 6
    Fig. 7
    Adaptor
    2 Long screws
    (ST4.2X20) Joists
    2 Long screws
    (ST4.2X20) Suspension bracket Adaptor
    Unit: inches (mm) 7/8 (21.6)B
    Fig. 8
    8 
    						
    							Screw    (ST4.2X12) Plug connector ReceptacleINSTALLATION    (JOIST MOUNTING-   ) CONTINUED6. Secure the fan body to adaptor by using machine
        screw (M4X8) and plug connector to receptacle. 
        (Fig.10)
    4. Insert the suspension bracket into fan body 
        (refering to step 2 of installation   , page 6).
    5. Insert the fan body into joists. (Fig.9)
    IMPORTANT:Make sure that adaptor claws are properly inserted
    into body slots.
    7. Secure the suspension bracket to joists by using
        long screws (ST4.2X20) and secure it to fan body
        by using screw    (ST4.2X12) in vertical direction.
        (Fig.11)
    8. Follow step 8 to 1 1 of installation   (page 8) to
        complete the installation work.
    When mounting 
    body and blower
    separately
    1. Loosen 4 screws (but
        do not remove them
        from blower). (Fig.12-1)
    2. Remove blower section.
        (Fig.12-2)
    3. Remove adaptor from 
        fan body and secure it 
        to joists as in Fig. 8 of 
        page 8.
    4. Insert fan body 
        (without blower section) 
        into joists. (Fig. 9)
    5. Secure the adaptor to
        fan body by using
        machine screw. 
        (M4X8). (Fig. 10)
    6. Secure the fan body
        to joists by using long
        screws (ST4.2X20).
        (Fig. 11)
    7. Insert the blower into 
        the fan body. (Fig. 12-3)
    8. Secure the blower.
        (Fig. 12-4) and plug
        connector to receptacle.
        (Fig. 10)
    Fig. 12-1
    Fig. 12-2
    Fig. 12-3
    Fig. 12-4
    4 Screws
    Adaptor
    Blower
    Fan body Fan body
    4 Screws
    Screw driver JoistJoist
    2 Long screws
    (ST4.2X20) Conduit
    Circular duct
    Junction box cover
    Fan bodyJoist
    Adaptor
    claws
    Fig. 9
    Slots
    Duct tape
    or clamps
    Fig. 10Fig. 11
    Machine
    screw
    (M4X8)
    Joist 9 
    						
    							Suspension bracket
    [16 inches and 19.2 inches
    horizontal joist]
    Suspension bracket
    [19.2 inches vertical joist] -Joist Screw
    (ST4.2X12)
    INSTALLATION     ( BETWEEN JOIST MOUNTING )  Suspension bracket
    The suspension bracket     can comply with
    different kinds of   -joist. INSTALLATION     (   - JOIST MOUNTING )  
    C3
    C1
    C4
    C2
    1. Before installation, secure the fan body to adaptor by
        using machine screw (M4X8) (Fig.13). Secure the 
        lighting unit to fan body (refering to Fig.6 of page 8).
    2. Connect the suspension bracket     to fan body. (Fig.14)
        (Select the hole by checking   -joist size fix the screw
        to the frame hole.)
    3. Connect the ventilating fan to the   -joist. (Fig.15)
    4. Follow step 5 to 11 of installation   (page 7 ~page 8) to
        complete the installation work.
    1. Before installation, secure the fan body to adaptor by
        using machine screw (M4X8) (Fig.13). Secure the 
        lighting unit to fan body (refering to Fig.6 of page 8).
    2. Insert the suspension bracket into bracket cover of 
        adaptor side and the back of the fan body. (Fig.16)
        (select the suspension bracket according to spacing A 
        as shown below)
    A
    16 inches and 19.2 inches
    horizontal joist
    19.2 inches vertical joist
    Suspension bracket
    [16 inches and 19.2 inches
    horizontal joist]
    Suspension bracket
    [19.2 inches vertical joist] Fig. 13
    Fig. 14
    Fig. 15
    Fan body
    Machine screw
    (M4X8) Suspension 
    bracket
    4 Long screws
    (ST4.2X20)
    Suspension bracket
    [16 inches and 19.2 inches
    horizontal joist]
    Suspension bracket
    [19.2 inches vertical joist] Fig. 16
    10
    4 kinds of   -joist
       inches (mm) hole
    mark
    C1
    C2
    C3
    C4
    9/16 (14.3)
    1 17/32 (38.9) 11/16 (17.5)
    31/32 (24.6)
    C 
    						