    Have a look at the manual Panasonic Ventilating Fan Fv 05vfl1 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							II I IIIII I
    READ AND SAVE THESE INSTRUCTIOINS.
    SpecificationsDimensions
    Description
    INSTALLATION
    INSTRUCTIONS
    9-12
    FV-05VFL1
    FV-09VFL1FV-07VFL1
    FV-11VFL1Ventilating Fan/
    Light Combination
    Maintenance (Replacement of Fluorescent Lamp or Night Lamp)
    Maintenance (Cleaning)
    Product Service12
    13
    14
    8-9 5-84
    4 3 32 2
    Please
    readthese
    instructionscarefullybeforeattempting
    toinstall,
    operate or service the Panasonic Ventilating Fan. Failure to comply
    with instructions couldresult in personal injury and/or property
    damage. Please retain this booklet for future reference.
    Table of Contents
    SuppliedAccessories
    Unpacking
    General Safety Information
    Installation( Joist Mounting )
    Installation( Wooden Header )
    Installation( In Existing Construction ) 
    						
    							DESCRIPTION
    2
    11 1
    1 11
    11 1
    connector
    Long screws
    Clamp
    Quantity Appearance
    Part name
    Grille
    Quantity
    Appearance
    Part name
    2
    FV-05VFL1 FV-07VFL1
    FV-09VFL1 FV-11VFL1
    (M4x30)
    (M4x8)
    The light unit is an energy-saving, lighting device which uses two 13W fluorescent lamps and produces almost the
    same illumination as a standard 100W incandescent lamp.
    Lamp cover
    Light unit
    13W
    Fluorescent
    lamp
    4W
    Incandescent
    lamp
    Light kit
    set plate
    (M4x16)
    2
    2
    8
    1
    (M4x6)
    plate
    Short screwsI
    Short screwII
    Short screwsIII2
    8
    Suspension
    bracketI
    Suspension
    bracketII
    Suspension
    bracketIII
    Thumb screw
    3 inch adaptor
    These Panasonic ceiling mount ventilating fan models use a low noise sirocco fan driven by a capacitor motor.
    The motor is designed to have an extended service life with reduced energy consumption.
    It also incorporates a thermal-cutoff for safety. The grille covering the main body is a spring-loaded,quick-remove
    type. A damper for preventing couterflow is provided.
    SUPPLIED ACCESSORIES 
    						
    							79.2(3 1/8)
    177.4 (7)
    265~385 (10 13/32~15 5/32)
    3
    DIMENSIONS
    12
    148 (5 13/16)
    Unit: mm(inches)
    No. No.
    120
    60Hz
    V Model No.Air direction
    ExhaustAir deliver at
    0.1" WG(CFM)
    Bracket cover
    Suspension plate
    Part name Part name
    Grille
    Thumb screw Body
    DamperAdaptor
    Junction box
    Night lamp connector
    13
    Light unit15
    Lamp cover17
    Light kit set plate1914
    16
    1813W lamp connectorFluorescent lamp (13W x 2)
    Night lamp (4W x 1) Motor connector3 inch adaptor connector
    FV-05VFL1 FV-07VFL1
    FV-09VFL1 FV-11VFL1
    FV-05VFL1
    FV-07VFL1
    FV-09VFL1
    FV-11VFL1
    Duct
    diameter
    (inch)
    3
    4
    3
    4
    3
    4
    3
    4Power consumption (w)Speed
    (RPM)
    Fan unitLight unitFluorescent lamp
    Night lamp
    1519
    1816
    8
    9
    4
    72 10330 (13 )
    73 (2 7/8)
    13
    20
    20Suspension bracket andII III
    Noise
    (sone)
    14.1
    14.1
    19.3
    19.5
    22.8
    23.826
    26
    26
    26
    26
    264
    4 4
    4
    4
    40.6
    0.4
    1.2
    0.9
    1.5
    1.550
    50
    60
    70
    70
    90921
    822
    1059
    908
    1175
    1018
    Specification are based on HV standard.I
    Junction box coverSuspension bracketI
    1211
    Weight
    Ib. (Kg)
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    (4 11/32)11 0
    84 (3 5/16)
    255.6 (10 1 / 16 )
    11
    14 17
    5
    6
    3
    56.7 (2 1/4)45
    (1 25/32 )
    139 ( 5 15 / 32 )
    1
    SPECIFICATIONS
    105(4 1/8)
    300.6(1
    127/32) 252.6 (9
    15/16 ) 94 (3 23/32)
    73 (2 7/8) 
    						
    							4
    45o
    UNPACKING
    Fig. B
    Floor
    equipment
    Do not install above or
    WARNING:
    CAUTION:
    Fig. A
    Adaptor
    Refer to the SuppliedAccessories list to verify that all parts are present.
    Unpack andcarefully remove unit from carton.
    1. Do not install this ventilating fan where air temperature may exceed40 C (104 F).oo
    2. Make certain that the electric service supply voltage is 120V, 60 Hz.
    3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and
    the Occupation Safety andHealth Act (OSHA).
    4. Always disconnect the power source before working on or near the fan, motor or junction box.
    5. Protect the power cordfrom sharp edges, oil, grease, hot surfaces, chemicals or other objects.
    6. Do not kink the power cord.
    7. Do not install the unit where ducts are configured as shown in Fig. A.
    8. Provide suction parts with proper ventilation.
    9. This unit is approvedfor use over a bathtub or shower when installedin a GFCI protected
    branch circuit.
    1. For general ventilating use only. Do not use to exhaust
    hazardous or explosive materials and vapors.
    2. Not for use in cooking area. (Fig .B)
    3. This product must be properly grounded.
    To reduce the risk of fire, electric shock or injury to persons, observe the following;
    A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
    B. Installation work andelectrical wiring must be done by qualifiedperson(s) in accordance with all applicable
    codes and standards, including fire-rated construction.
    C. Sufficient air is neededfor proper combustion andexhausting of gases through the flue (chimney) of fuel burning
    equipment to prevent backdrafting. Follow the heating equipment manufacture's guideline and safety standards
    such as those publishedby the National Fire Protection Association (NFPA), andthe American Society for Heating
    Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
    D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
    E. Ductedfans must always be ventedto the outdoors.
    F. These models are UL listedfor tub andshower enclosures.
    G. Solidstate controls may cause harmonic distortion which can cause motor humming noise.
    H. Before servicing or cleaning unit, switch power off at service panel andlock the service disconnecting
    means to prevent power from being switched on accidentally. When the service disconnecting means
    cannot be locked, securely fasten a prominent warning device, shch as a tag, to the service panel.
    I. NEVER place a switch where it can be reachedfrom a tub or shower.
    J. Not to be installedin a ceiling thermally insulatedto a value greater than R40.
    (Cooking area)
    inside this area
    Cooking
    GENERAL SAFETY INFORMATION
    45o 
    						
    							Leadwires
    Green wires
    Wire nutJunction boxConduit
    Duct
    Fig. 2
    Junction box cover
    Ceiling joist
    Long screwAdaptor Ceiling joist
    Fig. 1
    Damper
    Remove
    tape4Inch
    Adaptor
    Connection methodfor 3 inch adaptor connector
    5. Install circular duct (4 inch) or 3 inch adaptor connector
    andsecure it with duct tape. (Fig.3.1, Fig.3.2)
    CAUTION: Wiring diagram
    Joist spacing A shouldbe between 380mm (14 31/32inch) and
    265mm(10 7/16 inch).
    Keep the distance B (21.6mm,7/8 inch) for the thickness of
    ceiling board.
    2. Remove adaptor from body and secure to ceiling joists
    Tape
    using long screws (M4x30). Make sure the adaptor is level
    andsquare (perpendicular) with the joists. (Fig.2)
    Fan unit
    Red
    Capacitor
    WhiteMotorBlackGreen
    Junction box
    Night Lamp
    BallastLampBallastLamp
    Green
    Earth ground
    Black
    WhitePower Supply
    AC 120V 60Hz
    Power Supply
    AC 120V 60Hz
    Light unit
    Fig.3.2Fig.3.1
    B
    Adaptor
    Tape
    Duct
    INSTALLATION (JOIST MOUNTING)I
    1. Disconnect plug connector from receptacle before
    starting installation.
    IMPORTANT:
    Remove the tape from damper and adaptor before
    installation. As shown in Fig.1.
    CAUTION:
    3. Remove junction box cover andsecure conduit to junction box
    knock- out hole. (Fig.3)
    4. Refer to wiring diagram below.
    Using wire nuts, connect house power wires to ventilating fan
    wires: black to black; white to white;green to green.
    Replace the junction box cover.
    Mount junction box cover carefully so that leadwires are not
    pinched.
    3 inch adaptor connector
    Suspension
    bracketI
    5 
    						
    							Fig. 7
    Fan
    Plug connector
    Thumb screw
    Ceiling joist Fan body
    mm (inches)
    Adaptor
    ScrewScrew driver
    Ceiling joist
    Fan body Ceiling joist
    Fan body
    of page 5. 1.Loosen 4 screws (but do
    not remove them from
    blower).(Fig.5-1)
    When mounting
    body and blower
    separately
    8. Secure fan body to adaptor using two thumb screws.(Fig.7)
    9. Connect plug connector to receptacle .(Fig.8)II
    Make sure that body "Claws" are property inserted into adaptor
    slots.IMPORTANT:
    6. Remove ceiling section. (Fig.4)
    7. Insert fan body into ceiling. (Fig.6)
    6
    Receptacle
    (for fan)II
    Adapter
    Receptacle
    (for night lamp)Ii
    Receptacle
    (for 13W lamp)IiI
    Tape
    Tape
    10.Connect plug connector
    to receptacle . (Fig.8) IITape
    Tape
    290 (11 1/2
    )
    290 (11 1/2
    )
    INSTALLATION (JOIST MOUNTING) CONTINUEDI
    2. Remove blower section.
    (Fig.5-2)
    3.Remove adaptor from
    fan body and secure to
    ceiling joists as in Fig.2
    4.Insert fan body (without
    blower section) into
    ceiling.(Fig.6)
    5.Secure the adaptor and
    fan body using one thumb
    screw as shown in Fig.5-3.
    6.Secure the fan body to
    the ceiling joists as shown
    in Fig.9 andFig.10 of
    page 7.
    7.Insert the blower into the
    fan body. (Fig.5-4)
    8.Secure the blower by 4
    screws as shown in
    Fig.5-5.
    9.Mount the fan body with
    thumb screw (on the right
    side of bottom of the
    adaptor) as shown in
    Fig.7.
    Screw
    Fig. 5-1
    Blower
    Fan body
    Fig. 5-2
    Fig. 5-3
    Fig. 5-4
    Fig. 5-5
    Ceiling
    Ceiling joist
    Adaptor slotsClaws
    Fig.4
    Fig.
    6
    Fig. 8 
    						
    							Ceiling joist Ceiling joist
    Suspension bracket II
    Suspension bracket III
    Ceiling joist
    Suspension bracket II4-Long screws
    Suspension bracket III
    4W Night LampFluorescent lamp
    Light unit
    10. Secure fan body to ceiling joists using long screws (M4X30) in
    11. Secure suspension bracket andto the fan body using 2
    short screws (M4x6). (Fig.10)
    12. Fix the light kit set plate to the frame using 4 short screws
    (M4x6). (Fig.11)II III
    I
    III II
    13. Insert the plug connector andplug connector into the
    receptacle andreceptacle respectively, andattach the
    light unit to the fan unit with 2 short screws (M4x16) and1
    short screw (M4x8). (Fig.12)
    14. Insert the fluorescent lamps andscrew the night lamp into the
    light unit. (Fig.12)II III
    Ii III
    I
    II
    horizontal direction with suspension bracket and . (Fig. 9)II III
    Short screwsI
    7
    Fig. 12
    Short screwsII
    Short
    screwsIII
    Fig. 11
    Receptacles
    Light kit set plateShort
    screwsIII
    Short
    screwsIII
    Plug connector
    Plug connector
    ReceptacleIIIReceptacleII
    Plug connectorIII
    Plug connectorII
    Fig.9
    2-screws
    Fig. 10
    INSTALLATIONI(JOIST MOUNTING) CONTINUEDINSTALLATIONI(JOIST MOUNTING) CONTINUED 
    						
    							Fan body
    Thumb screws
    Mounting springLight unit Lamp Cover
    Fig. 13
    8
    1. Before installation, secure adaptor to fan body using two
    thumb screws. (Fig.14)
    Fig. 14
    Fig. 16
    15. Insert the lamp cover to the grille andattach the grille to the
    fan unit. (Fig.13)
    3. Insert the plug connector andplug connector into the
    receptacle andreceptacle respectively, andattach the
    light unit to the fan unit with 2 short screws (M4x16) and1
    short screw (M4 x 8). Insert the fluorescent lamps and
    screw the night lamp into the light unit. (Fig.12, Fig.16)II III
    II III
    I
    II 2. Fix the light kit set plate to the frame using 4 short screws
    (M4x6). (Fig.15)III
    Short
    screwsIShort
    screwII
    Light unit
    Fig. 15Light kit set plate
    Short
    screwsIIIShort
    screwsIII
    Junction
    box
    Slot
    Grille
    Grille
    INSTALLATION (JOIST MOUNTING) CONTINUEDI
    INSTALLATION (WOODEN HEADER)II 
    						
    							CAUTION:
    To install the ventilating fan, follow the procedures described in lnstallation II. Take the following precautions before
    installation.
    Long screwsJunction box cover
    mm (inches) Ventilating fan
    AdaptorCeiling joist Header Ceiling joist
    Wiring diagram CAUTION:Adaptor
    Fan unit
    Red
    Capacitor
    WhiteMotorBlackGreen
    Junction box
    Night Lamp
    BallastLampBallastLamp
    Green
    Earth ground
    Black
    WhitePower Supply
    AC 120V 60Hz
    Power Supply
    AC 120V 60Hz
    Light unit
    ,
    INSTALLATION (WOODEN HEADER) CONTINUEDII
    4. Install header between ceiling joists using nails or screws. (Fig.17)
    5. Install the ventilating fan andsecure with screws. (Fig.17 andFig.18)
    6. Insert the circular duct to the adaptor and secure with duct tape.
    Remove the junction box cover andsecure conduit to junction
    box knockout hole (7/8 inch) (Fig.18)
    7. Refer to wiring diagram.
    Using wire nuts, connect house power wires to ventilating fan wires:
    black to black; white to white; green to green.
    Replace the junction box cover.
    Mount junction box cover carefully so that leadwires are not
    pinched
    8. Finish ceiling work. Ceiling hole shouldbe alignedwith
    edge of the flange. (Fig.19 )
    9. Mount grille to fan body. (Fig.13, page 8.)
    Fig. 17
    Circular duct
    Fig.18
    Ceiling
    Flange
    Fig.19
    1. Installation in existing construction.
    Installing the ventilating fan in an existing building requires an accessible area (attic or crawl space) above the planned
    installation location or existing ducting and wiring.
    Check area above plannedinstallation location to be sure that:
    1. Duct work can be installedandthat area is sufficient for proper ventilation.
    2. Wiring can be run to plannedlocation.
    3. No wiring or other obstructions will interfere with installation.
    Inspect duct work and wiring before proceeding with installation.
    Plan suitable location for ventilating fan.(next to ceiling joist)
    9
    INSTALLATION (IN EXISTING CONSTRUCTION)III 
    						
    							Ceiling joist
    Ceiling
    Long screws
    Adaptor
    Duct
    Junction box cover Conduit mm (inches)Ceiling
    Suspension bracket I
    Suspension bracket II
    CAUTION:
    Fig. 20
    Fig. 21
    Fig. 22
    3 inch adaptor
    connector Duct tape
    10
    Before installation, provide inspection and maintenance access at a location that will not interfere with
    installation work shown in installation .II
    First, remove ceiling section according to Fig.4 of page 6.
    Install ventilating fan.
    2. Installation from accessible area above fan location.
    Inspect duct work and wiring before proceeding with installation.
    Remove ceiling section according to Fig.4 of page 6.
    Install ventilating fan.
    3. Installation without removing ceiling.
    Check area above plannedinstallation location to be sure that:
    1. Ensure that the square hole size in ceiling shouldbe sufficient according to Fig.20
    2. Duct work can be installedandthat area is sufficient for proper ventilation.
    3. Wiring can be run to plannedlocation.
    4. No wiring or other obstructions will interfere with installation.
    Loosen 4 screws (but do not remove them from blower) as
    shown in Fig.5-1 of page 6.
    Remove blower from fan body as shown in Fig.5-2 of page 6.
    and then remove adaptor from fan body.
    Remove junction box cover andsecure the existing conduit
    to junction box knockout hole.(Fig21)
    Refer to wiring diagram on page 9.
    Using wire nuts, connect house power wires to ventilating fan wires:
    black to black; white to white; green to green.
    Replace the junction box cover.
    Secure adaptor to ceiling joists with 4 long screws (M4X30)
    inside of the ceiling as shown in Fig.22.
    If the location is in the middle between 2
    joists, connect suspension bracket and
    as shown below.III
    Install circular duct(4 inch) or optional part (3 inch adaptor
    connector) andsecure it with cuct tape as shown in Fig.21.
    Ceiling joist
    Suspension bracketI
    INSTALLATION (IN EXISTING CONSTRUCTION) CONTINUEDIII
    260(10 1/4)
    260(10 1/4) 
    						