INSTALLATION INSTRUCTIONS Ventilating Fan FV-05VF1 FV-07VF1 FV-09VF1 FV-11VF1 READ AND SAVE THESE INSTRUCTIOINS. Please read these instructions carefully before attempting to install, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference. IIIII I SpecificationsDimensions Description 9-12 Maintenance Product Service12-13 13-148-9 6-84 4-54 32 2 Table of Contents Supplied Accessories Unpacking General Safety Information Installation ( Joist Mounting ) Installation ( Wooden Header ) Installation ( In Existing Construction )
FV-05VF1 FV-07VF1 FV-09VF1 FV-11VF1 2 81Thumb screw Long screw Quantity Appearance Part name Grille Suspension bracket I Suspension bracket II Screw Suspension bracket III Clamp Plate 3 inch adaptor connector(optional part for FV-05VF1 and FV-07VF1) 1 1 4 1 2 1 These Panasonic ceiling mount ventilating fan models use a low noise sirocco fan driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. It also incorporates a thermal-cutoff for safety. The grille covering the main body is a spring-loaded,quick-remove type. A damper for preventing couterflow is provided. SUPPLIED ACCESSORIESSUPPLIED ACCESSORIES DESCRIPTIONDESCRIPTION
Suspension plate IIJunction box cover Junction boxAdaptor Grille Part name Part name 330 (13) 84 (3 5/16) 36 7 1 92 DIMENSIONS 177.4 (7) 265~385 (10 13/32~15 5/32) FV-05VF1 FV-07VF1 FV-09VF1 FV-11VF1 300.6(1 1 27/32 )252.6 (9 15/16 ) 79.2(3 1/8) 56.7 (2 1/4) 105(4 1/8) 94 (3 23/32) 73 (2 7/8) 4 5 ( 1 25/ 3 2 ) 1 3 9 ( 5 1 5 / 3 2 ) 48 (4 11/32)110 255.6 (10 1 / 16 ) 148 (5 13/16) 12 5 11 10 Unit: mm(inches) No. No. Body Damper 1 2 3 4 5 67 8 9 10 11 12Connector Suspension bracket I Thumb screw 3 inch adaptor connector (only for FV-05VF1 and FV-07VF1) Bracket cover
Adaptor 4.2 (9.2) 4.2 (9.2) 3.9 (8.6) 20.0 Hz 60V Air direction SPECIFICATIONSSPECIFICATIONS GENERAL SAFETY INFORMATIONGENERAL SAFETY INFORMATION UNPACKINGUNPACKING Model No. FV-05VF1 FV-07VF1 FV-09VF1 FV-11VF1Exhaust 120 (W)Power consumption 14.0 24.0 34.0 639 739 835 948 Speed (RPM)Air deliver at 0.1 WG(CFM) 50 70 90 110 Weight Kg(Ib.) 4.1 (9.0) * At 0.0 Static pressure, (Pa) Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. o o1. Do not install this ventilating fan where air temperature may exceed 40 c (104 F). 2. Make certain that the electric service supply voltage is 120V, 60 Hz. 3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). 4. Always disconnect the power source before working on or near the fan, motor or junction box. 5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects. 6. Do not kink the power cord. 7. Do not install the unit where ducts are configured as shown in Fig. A. 8. Provide suction parts with proper ventilation. 9. This unit is approved for use over a bathtub or shower when installed in a GFCI protectedbranch circuit. Fig. A
Floor GENERAL SAFETY INFORMATION CONTINUEDGENERAL SAFETY INFORMATION CONTINUED CAUTION: 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. Not for use in cooking area. (Fig .B) 3. This product must be properly grounded. Do not install above or (Cooking area) inside this area o45o45 equipmentCooking Fig. B WARNING: To reduce the risk of fire, electric shock or injury to persons, observe the following; A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufactures guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. E. Ducted fans must always be vented to the outdoors. F. These models are UL listed for tub and shower enclosures. G. Solid state controls may cause harmonic distortion which can cause motor humming noise. H. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, shch as a tag, to the service panel. I. NEVER place a switch where it can be reached from a tub or shower. J. Not to be installed in a ceiling thermally insulated to a value greater than R40.
B 3 Fig. 3 Adaptor flange Long screw Fig. 1 4 Inch Adaptor Neutral Green Red M.C. Live Power Supply AC120V 60Hz Black 3 inch adaptor connector Duct tape Connection method for 3 inch adaptor connector IMPORTANT: Remove the tape from damper and adaptor before installation. As shown in Fig.1. INSTALLATION I (JOIST MOUNTING)INSTALLATION I (JOIST MOUNTING) 1. Disconnect plug connector from receptacle before starting installation. 2. Remove adaptor from body and secure to ceiling joists using long screws. (Fig.2) Keep th e distance B (21.6mm,7/8 inch) for the thickness of ceiling board. Joist spacing A should be between 380mm(14 31/32inch) and 265mm(10 7/16 inch). CAUTION: Wiring diagram 3. Remove junction box cover and secure conduit to junction box knock- out hole. (Fig.3) 4. Refer to wiring diagram below. Using wire nuts, connect house power wires to ventilating fan wires:black to black; white to white;green to green. Replace the junction box cover. 5.Install circular duct (4 inch) or optional part (3 inch adaptor connector) that is only for FV-05VF1 and FV-07VF1 and secure it with duct tape. CAUTION:Mount junction box cover carefully so that lead wires are not pinched. Motor Thermal Cutoff Black Black A.C. Capacitor White Earth White White Green Remove tape Damper Suspension bracket ICeiling joist Adaptor Ceiling joist Duct Junction box cover Wire nut Conduit Junction box Lead wires Green wires Fig. 2 12
FanReceptacle Fig. 7Thumb screw Fig. 6 Ceiling joist Claws Adapter slots Fan body Adapter Fig.5-5 Fig. 5-2 Fan body Fig. 5-1 AdapterWhen mounting body and blower separately 9. Connect plug connector to receptacle.(Fig.8) Make sure that body Claws are property inserted into adaptor slots. IMPORTANT: INSTALLATION I (JOIST MOUNTING) CONTINUEDINSTALLATION I (JOIST MOUNTING) CONTINUED 6. Remove ceiling section. (Fig.4) 7. Insert fan body into ceiling. (Fig.6) 8. Secure fan body to adaptor using two thumb screws.(Fig.7) 1.Loosen 4 screws (but do not remove them from blower).(Fig.5-1) 2. Remove blower section. 3.Remove adaptor from fan body and secure to ceiling joists as in Fig.2 4.Insert fan body (without blower section) into ceiling.(Fig.6) 5.Secure the adaptor and fan body using one thumb screw as shown in Fig.5-3. 6.Secure the fan body to the ceiling joists as shown in Fig.9 and Fig.10 of page 8. 7.Insert the blower into the fan body.(Fig.5-4) 8.Secure the blower by 4 screws as shown in Fig.5-5. 9.Mount the fan body with thumb screw (on the right side of bottom of the adaptor) as shown in Fig.7. (Fig.5-2) of page 6. Screw Blower Fan body Fig. 5-3Ceiling joist Fan body Ceiling joist Fig. 5-4 Screw Screw driver Ceiling Ceiling joist 260 (10 1/4 ) mm (inches) 260 (10 1/4 ) Fig.4 Plug connectorFig. 8
Fig.12 Fan body Thumb screws Ceiling Mounting spring Ceiling joistSuspension bracket II Suspension bracket III Suspension bracket II 4-Long screws Suspension bracket III 1.Before installation, secure fan body to adaptor using two thumb screws. (Fig.12) INSTALLATION I (JOIST MOUNTING) CONTINUEDINSTALLATION I (JOIST MOUNTING) CONTINUED 10. Secure fan body to ceiling joists using long screws in horizontal direction with suspension bracket II and III.(Fig.9) 11. Secure suspension bracket II and III to the fan body using 2 screws(Fig.10) 12. Replace ceiling and insert mounting springs into slots as shown and mount grille to fan body.(Fig.11) INSTALLATION II (WOODEN HEADER)INSTALLATION II (WOODEN HEADER) Ceiling joistFig.9 2-screws Fig.10 Slot Grille Fig.11
Live Adaptor mm (inches) CAUTION: Mount junction box cover carefully so that lead wires are not pinched INSTALLATION II (WOODEN HEADER) CONTINUEDINSTALLATION II (WOODEN HEADER) CONTINUED 2. Install header between ceiling joists using nails or screws. 3. Install the ventilating fan and secure with screws.(Fig.13 and Fig.14) 4. Insert the circular duct to the adaptor. Remove the junction box cover and secure conduit to junction box knockout hole (7/8 inch) (Fig.14 ) 5. Refer to wiring diagram. Using wire nuts,connect house power wires to ventilating fan wires: black to black; white to white; green to green. Replace the junction box cover. Long screwsJunction box cover Ventilating fan Ceiling joist Header Ceiling joist Wiring diagramAdaptor 6. Finish ceiling work. Ceiling hole should be aligned with edge of the flange. (Fig.15 ) 7. Mount grille to fan body. (Fig.11, page 8.) Circular duct Fig.13 Fig.14 Ceiling Flange Fig.15 CAUTION: To install the ventilating fan, follow the procedures described in lnstallation II. Take the following precautions before installation., 1. Installation in existing construction. Installing the ventilating fan in an existing building requires an accessible area (attic or crawl space) above the planned installation location or existing ducting and wiring. Check area above planned installation location to be sure that: 1. Duct work can be installed and that area is sufficient for proper ventilation. 2. Wiring can be run to planned location. 3. No wiring or other obstructions will interfere with installation. Inspect duct work and wiring before proceeding with installation. Plan suitable location for ventilating fan.(next to ceiling joist) INSTALLATION III (IN EXISTING CONSTRUCTION) Power Supply AC120V 60Hz Earth Motor Thermal Cutoff Black Black Black Red Capacitor White Green M.C. A.C. White White GreenNeutral
Fig. 18 Ceiling Adaptor Long screws Suspension bracket I Fig. 17 Junction box cover Conduit Fig. 16 Ceiling joist mm (inches)Ceiling Suspension bracket I Secure adaptor to ceiling joists with 4 long screws inside of the ceiling as shown in Fig.18. Wiring diagram CAUTION: Check area above planned installation location to be sure that: 1. Ensure that the square hole size in ceiling should be sufficient according to Fig.16 2. Duct work can be installed and that area is sufficient for proper ventilation. 3. Wiring can be run to planned location. 4. No wiring or other obstructions will interfere with installation. Before installation, provide inspection and maintenance access at a location that will not interfere with installation work shown in installation II. First, remove ceiling section according to Fig.4 of page 7. Install ventilating fan. 2. Installation from accessible area above fan location. Inspect duct work and wiring before proceeding with installation. Remove ceiling section according to Fig.4 of page 7. Install ventilating fan. 3. Installation without removing ceiling. Loosen 4 screws (but do not remove them from blower) as shown in Fig.5-1. Remove blower from fan body as shown in Fig.5-2 of page 6. remove adaptor from fan body. Remove junction box cover and secure the existing conduit to junction box knockout hole.(Fig.17) Refer to wiring diagram on page 9. Using wire nuts, connect house power wires to ventilating fan wires: black to black; white to white; green to green. Replace the junction box cover. INSTALLATION III (IN EXISTING CONSTRUCTION) CONTINUED Install circular duct(4 inch) or optional part (3 inch adaptor connector) that is only for FV-05VF1 and FV-07VF1 and secure it with duct tape as shown in Fig.17. Live Power Supply AC120V 60Hz Earth Thermal Cutoff Black Red Green M.C. A.C. WhiteNeutral Motor Black Black White White Capacitor If the location is in the middle between 2 joists, connect suspension bracket I and II as shown below. Suspension bracket II 260(10 1/4) 260(10 1/4) Duct Ceiling joist