Page 1
INSTALLATION INSTRUCTIONS Ventilating Fan FV-05VF1 FV-07VF1 FV-09VF1 FV-11VF1 READ AND SAVE THESE INSTRUCTIOINS. Please read these instructions carefully before attempting to install, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference. IIIII I SpecificationsDimensions Description 9-12 Maintenance Product Service12-13 13-148-9 6-84 4-54 32 2 Table of Contents...
Page 2
FV-05VF1 FV-07VF1 FV-09VF1 FV-11VF1 2 81Thumb screw Long screw Quantity Appearance Part name Grille Suspension bracket I Suspension bracket II Screw Suspension bracket III Clamp Plate 3 inch adaptor connector(optional part for FV-05VF1 and FV-07VF1) 1 1 4 1 2 1 These Panasonic ceiling mount ventilating fan models use a low noise sirocco fan driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. It also incorporates a thermal-cutoff for...
Page 3
Suspension plate IIJunction box cover Junction boxAdaptor Grille Part name Part name 330 (13) 84 (3 5/16) 36 7 1 92 DIMENSIONS 177.4 (7) 265~385 (10 13/32~15 5/32) FV-05VF1 FV-07VF1 FV-09VF1 FV-11VF1 300.6(1 1 27/32 )252.6 (9 15/16 ) 79.2(3 1/8) 56.7 (2 1/4) 105(4 1/8) 94 (3 23/32) 73 (2 7/8) 4 5 ( 1 25/ 3 2 ) 1 3 9 ( 5 1 5 / 3 2 ) 48 (4 11/32)110 255.6 (10 1 / 16 ) 148 (5 13/16) 12 5 11 10 Unit: mm(inches) No. No. Body Damper 1 2 3 4 5 67 8 9 10 11 12Connector Suspension...
Page 4
Adaptor 4.2 (9.2) 4.2 (9.2) 3.9 (8.6) 20.0 Hz 60V Air direction SPECIFICATIONSSPECIFICATIONS GENERAL SAFETY INFORMATIONGENERAL SAFETY INFORMATION UNPACKINGUNPACKING Model No. FV-05VF1 FV-07VF1 FV-09VF1 FV-11VF1Exhaust 120 (W)Power consumption 14.0 24.0 34.0 639 739 835 948 Speed (RPM)Air deliver at 0.1 WG(CFM) 50 70 90 110 Weight Kg(Ib.) 4.1 (9.0) * At 0.0 Static pressure, (Pa) Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. o...
Page 5
Floor GENERAL SAFETY INFORMATION CONTINUEDGENERAL SAFETY INFORMATION CONTINUED CAUTION: 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. Not for use in cooking area. (Fig .B) 3. This product must be properly grounded. Do not install above or (Cooking area) inside this area o45o45 equipmentCooking Fig. B WARNING: To reduce the risk of fire, electric shock or injury to persons, observe the following; A. Use this unit only in...
Page 6
B 3 Fig. 3 Adaptor flange Long screw Fig. 1 4 Inch Adaptor Neutral Green Red M.C. Live Power Supply AC120V 60Hz Black 3 inch adaptor connector Duct tape Connection method for 3 inch adaptor connector IMPORTANT: Remove the tape from damper and adaptor before installation. As shown in Fig.1. INSTALLATION I (JOIST MOUNTING)INSTALLATION I (JOIST MOUNTING) 1. Disconnect plug connector from receptacle before starting installation. 2. Remove adaptor from body and secure to ceiling joists using...
Page 7
FanReceptacle Fig. 7Thumb screw Fig. 6 Ceiling joist Claws Adapter slots Fan body Adapter Fig.5-5 Fig. 5-2 Fan body Fig. 5-1 AdapterWhen mounting body and blower separately 9. Connect plug connector to receptacle.(Fig.8) Make sure that body Claws are property inserted into adaptor slots. IMPORTANT: INSTALLATION I (JOIST MOUNTING) CONTINUEDINSTALLATION I (JOIST MOUNTING) CONTINUED 6. Remove ceiling section. (Fig.4) 7. Insert fan body into ceiling. (Fig.6) 8. Secure fan body to adaptor using two...
Page 8
Fig.12 Fan body Thumb screws Ceiling Mounting spring Ceiling joistSuspension bracket II Suspension bracket III Suspension bracket II 4-Long screws Suspension bracket III 1.Before installation, secure fan body to adaptor using two thumb screws. (Fig.12) INSTALLATION I (JOIST MOUNTING) CONTINUEDINSTALLATION I (JOIST MOUNTING) CONTINUED 10. Secure fan body to ceiling joists using long screws in horizontal direction with suspension bracket II and III.(Fig.9) 11. Secure suspension bracket II and...
Page 9
Live Adaptor mm (inches) CAUTION: Mount junction box cover carefully so that lead wires are not pinched INSTALLATION II (WOODEN HEADER) CONTINUEDINSTALLATION II (WOODEN HEADER) CONTINUED 2. Install header between ceiling joists using nails or screws. 3. Install the ventilating fan and secure with screws.(Fig.13 and Fig.14) 4. Insert the circular duct to the adaptor. Remove the junction box cover and secure conduit to junction box knockout hole (7/8 inch) (Fig.14 ) 5. Refer to wiring...
Page 10
Fig. 18 Ceiling Adaptor Long screws Suspension bracket I Fig. 17 Junction box cover Conduit Fig. 16 Ceiling joist mm (inches)Ceiling Suspension bracket I Secure adaptor to ceiling joists with 4 long screws inside of the ceiling as shown in Fig.18. Wiring diagram CAUTION: Check area above planned installation location to be sure that: 1. Ensure that the square hole size in ceiling should be sufficient according to Fig.16 2. Duct work can be installed and that area is sufficient for proper ventilation....