- 22 - - 31 - For best deep down cleaning, use the “1” setting. However, you may need to raise the height to make some jobs easier, (such as throw rugs and some deep pile carpets) and to prevent the vacuum cleaner from shutting off. Suggested settings are: “1” - most carpets and bare floors. “2” - low to medium pile. “3” - medium to deep pile. “4” - shag; deep pile; scatter rugs.➢ ➢ Lower wand from upright position by pressing on the handle release pedal. ➢ ➢ Select a pile height setting by pressing the...
Page 32
- 21 - - 32 - ➢ ➢ Presione On/Off switch para encender la unidad y el POWER NOZZLE. FonctionnementCordon d’alimentation Cordón eléctrico ➢ ➢ Appuyer sur l’interrupteur “On/Off”pour mettre laspirateur et la tête motorisée en marche Interrupteur Control On-Off Para operar la aspiridora ➢ ➢ Tire del cordón para sacarlo del receptáculo hasta tener la longitud deseada. ➢ ➢ Asegure el cordón en el clip para preveenir que se rebobine accidentalmente. ➢ ➢ Conecte el cordón eléctrico polarizado en un enchufe...
Page 33
- 33 - NOTE: To reduce the risk of electrical shock, this vacuum has a polarized plug, one blade is wider than the other. This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. DO NO T CHANGE THE PLUG IN ANY WAY. Only use outlets near the floor. Power Cord TO OPERATE CLEANER On-Off Switch ➢ ➢ Press “On/Off” switch to start canister and POWER NOZZLE....
Page 34
- 19 - - 34 - Always follow all safety precautions when cleaning and servicing the POWER NOZZLE. WARNING Electrical Shock or Personal Injury Hazard.Disconnect the electrical supply before servicing or cleaning the unit. Failure to do so could result in electrical shock or personal injury from cleaner suddenly starting. ➢ ➢ To remove light cover use a flat blade screwdriver, gently prying one side of the light cover up. ➢ ➢ After freeing one side, lift up to remove. ➢ ➢ Push in and turn bulb counter-...
Page 35
- 18 -- 35 - FEATURES Overload ProtectorSuction ControlHose Swivel ➢ ➢ The hose swivel allows the hose to turn without moving the canister. This is helpful for cleaning in small areas. ➢ ➢ Check hose for twisting before pulling canister.➢ ➢ Suction control allows you to change vacuum suction for different fabric and carpet weight. ➢ ➢ Opening control decreases suction for draperies and lightweight rugs. ➢ ➢ Closing control increases suction for upholstery and carpets.➢ ➢ The overload protector stops the...
Page 36
- 17 - - 36 - ➢ ➢ Aligner la languette de blocage du tuyau avec lencoche du couvercle du chariot et insérer le tuyau dans le chariot jusqu’à ce qu’il s’enclenche. Pour enlever: ➢ ➢ Soulever la languette de blocage du tuyau et tirer le tuyau vers le haut. ➢ ➢ Insérer la poignée dans le tube jusqu’à ce que le bouton de blocage s’enclenche en place. ➢ ➢ S’assurer que le tuyau souple n’est pas tortillé. Pour enlever: ➢ ➢ Appuyer sur le bouton de dégagement du manche et tirer la poignée vers le haut. ➢ ➢...
Page 37
- 37 - ➢ ➢ Line up the hose latch tab and notch in canister hood and insert hose into canister until it snaps in place. To Remove:➢ ➢ Lift hose latch tab upward and pull up on hose. ➢ ➢ Insert handle into wand until lock button snaps in place. ➢ ➢ Be sure the hose is not twisted.To Remove:➢ ➢ Press handle release button and pull up on handle. Hose Latch TabLanguette de blocage du tuyau Pestaña de sujeción de la manguera NotchFente Ranura ➢ ➢ It is normal for the canister hood to come off when it is...
Page 38
- 38 -- 15 - Montaje AssemblageTête motorisée Tubes POWER NOZZLE Tubos ➢ ➢ Introduzca los tubos en la POWER NOZZLE hasta que el botón del tubo quede fijo en posición. ➢ ➢ Conecte el enchufe y cordón de la power nozzle. ➢ ➢ NO LO FUERCE. ➢ ➢ El área elevada del enchufe tiene que estar hacia la mano. ➢ ➢ Si es difícil de ensamblar, gire el enchufe y trate de nuevo.Para Retirar:➢ ➢ Desconectar cordón. ➢ ➢ Sujete el POWER NOZZLE con el pie y gire los tubos a favor de las manecillas del reloj hasta que el...
Page 39
- 14 -- 39 - ASSEMBLY ➢ ➢ Insert wands into POWER NOZZLE until the wand button snaps into the grooved slot. ➢ ➢ Connect POWER NOZZLE plug and cord as shown. ➢ ➢ Do not force. ➢ ➢ Raised area of plug must face toward hand. ➢ ➢ If hard to install, turn the plug over and try again.To Remove:➢ Unplug the cord. ➢ Steady POWER NOZZLE with foot and turn wand counter-clockwise until lock button disappears. ➢ Pull wands out of POWER NOZZLE. ➢ ➢ Slide wands together until wand button snaps into...
Page 40
- 13 - - 40 - TO CHECK BRUSHES:➢ ➢ When brushes are worn to the level of the base support bar, replace the agitator.TO REPLACE BRUSH AGITATOR UNIT➢ ➢ Remove POWER NOZZLE cover, belt and agitator assembly. (See “REMOVING BELT”). ➢ ➢ Remove agitator supports, washers, screws, end brush, brush sprocket, and brush sprocket flange from ends of agitator assembly. ➢ ➢ Replace agitator assembly. ➢ ➢ Reassemble agitator assembly. ➢ ➢ To line up screw holes in dowel, sprocket and end brush, be sure the brush...