Page 11
4. WIRING CONNECTION Wiring cables 0 Be sure to connect as follows Y: YELLOW - Connect the cables to the modular connector and modular screw terminal so that the wires Y, G, R and B at both ends of the cable are parallel. Note that there are no polarity indications (plus or minus) for outer pins B and Y and inner pins R and G. CASE 1 Connection of modular connector and modular-screw terminal. CASE 2 Connection to modular-screw terminal at both ends. .,;a~;m+~*~~E;,,:,. Modular-screw terminal...
Page 12
5. CONNECTION OF OPTIONAL UNIT If you are not using key telephones other than those initially mounted, door boxes or external paging, you can disregard this section. Variation of card connection For installing more telephones, three variations are available to connect station card as shown below. Extention Nos. are indicated on each card depending on jacks. CASE 1 Key TEL 24 pcs SLT 0 DPH COL LCI LC2 LC3 LC-S (4KT) (4KT) (4KT) Station card I (VA-30940) CASE 2 Key TEL 22 PCS SLT 2 pcs...
Page 13
5. CONNECTION OF OPTIONAL UNIT c Extension of CO/PBX line Be sure the power switch is off, before installing or removing the cards. Make connections of an CO/PBX line card and to respective CO/PBX line according to the following procedure. When inserting the CO/PBX line card, make sure that the card top and bottom ribs are aligned with the respective slots located at the regular positions inside the key service unit. l Connection of CO/PBX line card WA- 82444) Insert the CO/PBX line card into the...
Page 14
( Connection of direct station selector (DSS) Profrom the connection of a direct station selector (DSS) and the fixing of the DSS console to a key telephone, according to the following procedures. However, when you use a DSS, programming must be performed (See page 45). 0 Connection of DSS console (VA- 82430) Connect the DSS console to the “EXT No. 11” connector-located inside the KSU. Note that the DSS console is paired for use with the key telephone connected to the “EXT No. IO” con- nector...
Page 15
5. CONNECTION OF OPTIONAL UNIT ( Connections of single line telephone or 2key TELsl2SLTs Make connections according to the following single line telephone connecting method and the 2 Key TEL/2 SLT connecting method. When inserting a card, make sure that the card top and bottom ribs are aligned with the respective slots located at the regular positions inside the key service unit. Programming is required for connecting a single fine telephone (See page 63). 0 Single line telephone (1) Connection...
Page 16
Connection Qf door box Make connections of a door box card and of door box according to the following procedure. l Door box card (VA-30960) Insert a door box card into the key service unit. This one card is capable of making 2 door boxes usable. This card may be used for sensor and door openers. (See page 14) l Connection of door box Connect Door box A and B to the screw terminals (2 terminals make a pair) located on the door box card. Door box 6 Door box A 13 3.86 in Door box A Door box...
Page 17
5. CONNECTION OF OPTIONAL UNIT Connections of sensor and door opener Make connections of sensor and door opener according to the following procedures. l Connection of sensor (1) Insert a door box card (VA-30960) into the key service unit. This card makes sensor usable and also be used for door box. (See page 13) (2) Connect the sensor terminals (screw terminals) on the door box card to sensor to be used and must meet the following requirements for connec- tion. Requirements for connection...
Page 18
Connection of SMDR - This system enables the output from KSU call record data for a telephone (duration of call, etc.) through the RS-232C inter- face. These data are output by the printer connected to KSU. Programming is necessary for outputting from KSU. (See page 48) 0 Connection of printer Connect the RS-232C connector of KSU and the printer (KX-PI 08Oi) by means of the RS-232C cable. Note that because the printer (KX-P1080i) uses a parallel interface, KX-PIID is also necessary. See the manual...
Page 19
5. CONNECTION OF OPTIONAL UNIT 14 25 VA-8241 0 RS-232C I I Printer RS-232C(KX-PilD) Circuit Type EIN Signal Name Pin No. and Connection Signal Name Circuit Type (EIA) AA FG 1 1 I, BB RXD 2 . 2 TXD , -, , BA TXD 3 .3 RXI-I 1 RR CD DTR 6 . ._.- YY I I -+6 DSR cc AB SG 7 7 SG AB I I 1 CB ( CTS 1 20 4 20 DTR CD 16
Page 20
External music on hold source and external paging system Make connections of the external music on hold (MOH) source and of the external paging system according to the following a External paging system (1 ) Connect an external amplifier to the “EPA-OUT” jack and to the “EPA-C” terminals inside the key service unit. The “EPA-C” terminals are to control turning ON/OFF of the external amplifier power. procedure. 0 External music on hold source (1) Set the “MOH” switch inside the key service...