Page 11
- 10 (E) - ENGLISH Connections CONTROL OUT TO PAN/TILT HEAD Main unit Control panel (max. 1000 m) (max. 500 m) Multi-function controller AW-RP605A 10BASE-T (UTP category 5) straight cable AC adapter AW-PS505A Convertible camera Camera cable supplied with AW-PH400 AC power cable supplied with AW-PH400 Protocol converter AW-IF400G AC adapter AW-PS505A Zoom lens IP/RP Indoor pan/tilt head AW-PH400 When controlling AW-PH400 from AW-RP605A (AW-RP605) • Switch settings SW1SW2SET UP 1234...
Page 12
- 11 (E) - Connections (max. 1000 m)(max. 500 m) Multi hybrid control panel AW-RP555 10BASE-T (UTP category 5) straight cable AC adapter AW-PS505A Convertible camera Camera cable supplied with AW-PH400 AC power cable supplied with AW-PH400 Protocol converter AW-IF400G AC adapter AW-PS505A Zoom lens IP/RP Indoor pan/tilt head AW-PH400 When controlling AW-PH400 from AW-RP555 • Switch settings SW1SW2SET UP 1234 OFFOFFONOFFON(300 deg)OFF(190 deg)OFF
Page 13
- 12 (E) - ENGLISH Connections (max. 1000 m)(max. 500 m) Multi-function controller AW-RP655 10BASE-T (UTP category 5) straight cable AC adapter AW-PS505A Convertible camera Camera cable supplied with AW-PH400 AC power cable supplied with AW-PH400 Protocol converter AW-IF400G AC adapter AW-PS505A Zoom lens IP/RP Indoor pan/tilt head AW-PH400 When controlling AW-PH400 from AW-RP655 • Switch settings SW1SW2SET UP 1234 OFFOFFONOFFON(300 deg)OFF(190 deg)OFF
Page 14
- 13 (E) - Connections When controlling AW-PH350 from AW-RP400 CONTROL IN IP/RP Indoor pan/tilt headAW-PH350 Pan/tilt control panel AW-RP400 CONTROL OUT TO PAN/TILT HEAD 10BASE-T (UTP category 5) straight cable Protocol converter AW-IF400G Remote operation panel AW-CB400 AC adapter AW-PS505A Convertible camera Camera cable AW-CA50T29 AW-CA50C29 AC adapter AW-PS300A Zoom lens AC adapter AW-PS505A (max. 500 m) (max. 1000 m) • Switch settings SW1SW2SET UP 1234 OFFONOFFONOFFOFF
Page 15
- 14 (E) - ENGLISH Connections When controlling AW-PH360 from AW-RP400 (The tracing memory function is not available.) Set the SW1 switch on the CPU circuit board of AW-PH360 to “For RP605”. (For details, refer to the operating instructions for the AW-PH360.) CONTROL IN IP/RP Indoor pan/tilt head AW-PH360 Pan/tilt control panel AW-RP400 CONTROL OUT TO PAN/TILT HEAD 10BASE-T (UTP category 5) straight cable Protocol converter AW-IF400G Remote operation panel AW-CB400 AC adapter AW-PS505A...
Page 16
- 15 (E) - Connections When controlling AW-PH650 from AW-RP400 ( For the connections of the AW-PH650 pan/tilt head, camera housing, and camera, refer to the operating instructions for the AW-PH650.) Pan/tilt control panel AW-RP400 CONTROL OUT TO PAN/TILT HEAD 10BASE-T (UTP category 5) straight cable Protocol converter AW-IF400G Remote operation panel AW-CB400 AC adapter AW-PS505A AC adapter AW-PS505A (max. 500 m) (max. 1000 m)• Switch settings SW1SW2SET UP 1234 OFFONOFFONOFFOFF Outdoor pan/tilt...
Page 17
- 16 (E) - ENGLISH Connections Pan/tilt control panelAW-RP400Remote operation panel AW-CB400 CONTROL OUT TO PAN/TILT HEAD 10BASE-T (UTP category 5) straight cable Protocol converter AW-IF400G IP/RP Indoor pan/tilt head AW-PH400 When using the extended distance transmission function of AW-RP400 and AW-PH400 AC adapter AW-PS505A Convertible camera Camera cable supplied with AW-PH400 AC power cable supplied with AW-PH400 Zoom lens AC adapter AW-PS505A (max. 500 m) (max. 500 m) • Switch...
Page 18
- 17 (E) - Indoor pan/tilt headAW-PH360 Pan/tilt control panel AW-RP400 CONTROL OUT TO PAN/TILT HEAD 10BASE-T (UTP category 5) straight cable Protocol converter AW-IF400G Remote operation panel AW-CB400 AC adapter AW-PS505A Convertible camera Camera cable supplied with AW-PH360 AC adapter AW-PS300A Zoom lens AC adapter AW-PS505A (max. 500 m) (max. 500 m) Connections When using the extended distance transmission function of AW-RP400 and AW-PH360 (The tracing memory function is available.) •...
Page 19
- 18 (E) - ENGLISH 1/4(6) 1-15/16(50) 9/16(15) 5-11/16(145) 3-3/8(85) 1-3/16(30) Appearance For mounting and other applications, use the screw (M3 screw) holes in the side panels. Do not use screws longer than 10 mm. Unit: inch (mm) M3 screw hole (in 4 locations) ( Located in the same positions on both sides)
Page 20
- 19 (E) - Specifications Controller supported: AW-RP400, AW-RP555, AW-RP605, AW-RP605A, AW-RP655 Pan/tilt head supported: AW-PH350, AW-PH360, AW-PH400, AW-PH650 Input connectors DC 12 V IN socket: Supply DC 12 V from the general-purpose AC adapter. (Recommended AC adapter: AW-PS505A) Input/Output connector CONTROLLER: RJ45, modular jack 10BASE-T straight cable (UTP category 5) PAN-TILT HEAD: RJ45, modular jack 10BASE-T straight cable (UTP category 5) Switch functions: Controller...